Evaluating spectral performance for quantitative contrast-enhanced breast CT with a GaAs based photon counting detector: a simulation approach

被引:0
作者
Ghammraoui, Bahaa [1 ]
Ghani, Muhammad Usman [1 ]
Glick, Stephen J. [1 ]
机构
[1] US FDA, Div Imaging Diagnost & Software Reliabil, Off Sci & Engn Labs, Ctr Devices & Radiol Hlth, Silver Spring, MD 20993 USA
来源
BIOMEDICAL PHYSICS & ENGINEERING EXPRESS | 2024年 / 10卷 / 05期
关键词
Photon Counting Detectors (PCDs); quantitative iodine imaging; material decomposition;
D O I
10.1088/2057-1976/ad5f96
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Quantitative contrast-enhanced breast computed tomography (CT) has the potential to improve the diagnosis and management of breast cancer. Traditional CT methods using energy-integrated detectors and dual-exposure images with different incident spectra for material discrimination can increase patient radiation dose and be susceptible to motion artifacts and spectral resolution loss. Photon Counting Detectors (PCDs) offer a promising alternative approach, enabling acquisition of multiple energy levels in a single exposure and potentially better energy resolution. Gallium arsenide (GaAs) is particularly promising for breast PCD-CT due to its high quantum efficiency and reduction of fluorescence x-rays escaping the pixel within the breast imaging energy range. In this study, the spectral performance of a GaAs PCD for quantitative iodine contrast-enhanced breast CT was evaluated. A GaAs detector with a pixel size of 100 mu m, a thickness of 500 mu m was simulated. Simulations were performed using cylindrical phantoms of varying diameters (10 cm, 12 cm, and 16 cm) with different concentrations and locations of iodine inserts, using incident spectra of 50, 55, and 60 kVp with 2 mm of added aluminum filtration and and a mean glandular dose of 10 mGy. We accounted for the effects of beam hardening and energy detector response using TIGRE CT open-source software and the publicly available Photon Counting Toolkit (PcTK). Material-specific images of the breast phantom were produced using both projection and image-based material decomposition methods, and iodine component images were used to estimate iodine intake. Accuracy and precision of the proposed methods for estimating iodine concentration in breast CT images were assessed for different material decomposition methods, incident spectra, and breast phantom thicknesses. The results showed that both the beam hardening effect and imperfection in the detector response had a significant impact on performance in terms of Root Mean Squared Error (RMSE), precision, and accuracy of estimating iodine intake in the breast. Furthermore, the study demonstrated the effectiveness of both material decomposition methods in making accurate and precise iodine concentration predictions using a GaAs-based photon counting breast CT system, with better performance when applying the projection-based material decomposition approach. The study highlights the potential of GaAs-based photon counting breast CT systems as viable alternatives to traditional imaging methods in terms of material decomposition and iodine concentration estimation, and proposes phantoms and figures of merit to assess their performance.
引用
收藏
页数:13
相关论文
共 32 条
  • [1] Almqvist H., 2023, Acad. Radiol, VS1076-6332, P338
  • [2] Conspicuity of suspicious breast lesions on contrast enhanced breast CT compared to digital breast tomosynthesis and mammography
    Aminololama-Shakeri, Shadi
    Abbey, Craig K.
    Lopez, Javier E.
    Hernandez, Andrew M.
    Gazi, Peymon
    Boone, John M.
    Lindfors, Karen K.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2019, 92 (1097)
  • [3] Photon Counting Detectors for X-Ray Imaging With Emphasis on CT
    Ballabriga, R.
    Alozy, J.
    Bandi, F. N.
    Campbell, M.
    Egidos, N.
    Fernandez-Tenllado, J. M.
    Heijne, E. H. M.
    Kremastiotis, I.
    Llopart, X.
    Madsen, B. J.
    Pennicard, D.
    Sriskaran, V.
    Tlustos, L.
    [J]. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2021, 5 (04) : 422 - 440
  • [4] TIGRE: a MATLAB-GPU toolbox for CBCT image reconstruction
    Biguri, Ander
    Dosanjh, Manjit
    Hancock, Steven
    Soleimani, Manuchehr
    [J]. BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2016, 2 (05):
  • [5] AN ACCURATE METHOD FOR DIRECT DUAL-ENERGY CALIBRATION AND DECOMPOSITION
    CARDINAL, HN
    FENSTER, A
    [J]. MEDICAL PHYSICS, 1990, 17 (03) : 327 - 341
  • [6] Characteristic performance evaluation of a photon counting Si strip detector for low dose spectral breast CT imaging
    Cho, Hyo-Min
    Barber, William C.
    Ding, Huanjun
    Iwanczyk, Jan S.
    Molloi, Sabee
    [J]. MEDICAL PHYSICS, 2014, 41 (09)
  • [7] Evans S., 1998, J. Radiol. Prot, V18, DOI [10.1088/0952-4746/18/1/026, DOI 10.1088/0952-4746/18/1/026]
  • [8] Multi-step material decomposition for spectral computed tomography
    Fredette, Nathaniel R.
    Kavuri, Amar
    Das, Mini
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (14)
  • [9] Inclusion of a GaAs detector model in the Photon Counting Toolkit software for the study of breast imaging systems
    Ghammraoui, Bahaa
    Taguchi, Katsuyuki
    Glick, Stephen J.
    [J]. PLOS ONE, 2023, 18 (06):
  • [10] Characterization of a GaAs photon-counting detector for mammography
    Ghammraoui, Bahaa
    Gkoumas, Spyridon
    Glick, Stephen J.
    [J]. JOURNAL OF MEDICAL IMAGING, 2021, 8 (03)