Analysis of the Efficiency of the Bivalent Parallel Mode of Operation of Heat Pumps in an Individual Residential Building: a Study of the Operating Modes of the Heat Supply System

被引:0
|
作者
Babayeva, Sevinj [1 ]
Nasirov, Shukur [1 ]
机构
[1] Azerbaijan State Oil & Ind Univ, Baku, Azerbaijan
来源
PRZEGLAD ELEKTROTECHNICZNY | 2024年 / 100卷 / 09期
关键词
heat supply; heat pump; bivalent-parallel mode; soil probe; solar collector; computer modeling; storage tank;
D O I
10.15199/48.2024.09.46
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The article uses computer modeling to study the use of ground heat pumps from alternative energy sources in the heat supply of the city of Kelbajar. For this purpose, the experience of developed countries was studied and a diagram of the heat supply system of the object under study was selected using computer modeling. The bivalent-parallel operating mode of the heat pump system was adopted and studied, and the conversion coefficient of the heat pump was calculated. The storage tank and its parameters for heat accumulation are selected. An auxiliary boiler was selected to meet the heating demand during the peak period and its characteristic parameters were determined. A solar collector was used as an additional heat source. The quantity, geometric dimensions and other parameters of the solar collector have been determined. The characteristics of the soil probe are given in the table. It is accepted that the working fluid of the probe is a 25% water-glycol solution. The temperature of the soil around the probe, the temperature of the working fluid at the inlet and outlet of the heat pump are determined and specified in the form of a graph. For the heating system, the heat load of the heat pump, solar collector, auxiliary boiler into the system and the conversion coefficient of the heat pump are graphically shown. As a result of the simulation, the energy produced (annual), losses (annual), energy used (annual), solar circuit, the required power and presented in the form of a table. The influence of the heat pump system on the environment is studied and it is shown that it is an environmentally friendly heat and cold supply system.
引用
收藏
页码:235 / 238
页数:4
相关论文
共 10 条
  • [1] Performance and operation strategy optimization of a new dual-source building energy supply system with heat pumps and energy storage
    Wang, Yubo
    Quan, Zhenhua
    Jing, Heran
    Wang, Lincheng
    Zhao, Yaohua
    ENERGY CONVERSION AND MANAGEMENT, 2021, 239
  • [2] Efficiency Improvement of Eco-Friendly Solar Heat Supply System as a Building Coating
    Voznyak, Orest
    Spodyniuk, Nadiia
    Antypov, Ievgen
    Dudkiewicz, Edyta
    Kasynets, Mariana
    Savchenko, Olena
    Tarasenko, Svitlana
    SUSTAINABILITY, 2023, 15 (03)
  • [3] FEASIBILITY ANALYSIS OF WATER MAIN GEOTHERMAL HEAT PUMP SYSTEM FOR RESIDENTIAL BUILDING APPLICATIONS
    Kohut, Brian L.
    Tao, Yong X.
    8TH THERMAL AND FLUIDS ENGINEERING CONFERENCE, 2023, : 737 - 746
  • [4] An Analysis of Solar Heating System Assisted by Ground-source Heat Pumps in Office Building
    Wang, Zhigang
    Huang, Daxing
    Wang, Pan
    Shen, Qiang
    Zhang, Qingnan
    Sun, Yuexia
    9TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING (ISHVAC) JOINT WITH THE 3RD INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT (COBEE), 2015, 121 : 1406 - 1412
  • [5] Method of Diagnostics of Operation Modes of Individual Heat Supply Units, Allowing to Detect Pre-Emergency Situations at an Early Stage
    Dvortsevoy, A. I.
    Borush, O. V.
    Khoreva, V. A.
    Yakovina, I. N.
    PROBLEMELE ENERGETICII REGIONALE, 2024, (04): : 21 - 33
  • [6] Calculation studies of the heat supply system operating mode influence on the gas tube boiler heating surfaces temperatures
    Mikhailov, A. G.
    Kikhtenko, V. A.
    Slobodina, E. N.
    Stepashkin, I. A.
    IV INTERNATIONAL SCIENTIFIC AND TECHNICAL CONFERENCE MECHANICAL SCIENCE AND TECHNOLOGY UPDATE (MSTU-2020), 2020, 1546
  • [7] A COMPARATIVE STUDY OF INDUSTRIAL HEAT SUPPLY BASED ON SECOND-LAW ANALYSIS AND OPERATING COSTS
    Wolf, Magdalena
    Detzlhofer, Thomas
    Proll, Tobias
    THERMAL SCIENCE, 2018, 22 (05): : 2203 - 2213
  • [8] The Study on the Performance of Solar Photovoltaic and Air Source Heat Pump Composite Building Energy Supply System
    Tong, Jiannan
    Quan, Zhenhua
    Zhao, Yaohua
    Wang, Gang
    Cai, Junjie
    Chi, Yuanying
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 4082 - 4089
  • [9] Ice source heat pump system for energy supply via gas pipelines-Part1: Performance analysis in residential units
    Mehdipour, Ramin
    Garvey, Seamus
    Baniamerian, Zahra
    Cardenas, Bruno
    ENERGY, 2024, 309
  • [10] Study on the Optimal Solar Fraction of Solar Water Heating System Combined with Heat Pump Unit for Hot Water Supply in Residential Buildings
    Wang, Zhiwei
    Gao, Zhijie
    Zhao, Jifeng
    Xue, Zunyi
    2011 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2011,