Purpose Ulnar shortening osteotomy can be used to treat ulnar impaction syndrome and other causes of ulnar wrist pain. Distal metaphyseal ulnar shortening osteotomy (DMUSO) is one technique that has been proposed to reduce the complications seen with a diaphyseal USO or a wafer resection. However, to our knowledge, the optimal fi xation construct for DMUSO has not been studied. We sought to characterize the biomechanical stiffness and rotational stability of different DMUSO constructs. Methods A DMUSO was performed on 40 human cadaveric ulnas using 4 different fi xation constructs (10 specimens per group): one 3.0 mm antegrade screw; two 2.2 mm antegrade screws; one 3.0 mm retrograde screw; and two 2.2 mm retrograde screws. Biaxial testing using axial load and cyclical axial torque was performed until failure, defined fi ned as 10 degrees degrees of rotation or 2 mm displacement. Specimens were assessed for stiffness at failure. Bone density was assessed using the second metacarpal cortical percentage. Results Bone density was similar between all 4 testing groups. Of the 4 groups, the 2 ante- grade screw group exhibited the highest rotational stiffness of 232 +/- 102 Nm/deg. In paired analysis, this was significantly fi cantly greater than 1 retrograde screw constructs. In multivariable analysis, 2-screw constructs were significantly fi cantly stiffer than 1 screw and antegrade constructs were significantly fi cantly stiffer than retrograde. Maximum failure torque did not differ with orientation, but 2 screws failed at significantly fi cantly higher torques. Conclusion Using 2 screws for DMUSO fixation constructs may provide higher stiffness and maximum failure torque, and antegrade screw constructs may provide more stiffness than retrograde constructs.
引用
收藏
页码:928e1 / 928e7
页数:7
相关论文
共 50 条
  • [21] Comparative Study of Dorsal and Volar Plating for Ulnar Shortening Osteotomy
    Ozasa, Yasuhiro
    Iba, Kousuke
    Takahashi, Nobuyuki
    Wada, Takuro
    Yamashita, Toshihiko
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2020, 25 (01) : 54 - 58
  • [22] Ulnar shortening osteotomy [Die ulnaverkürzungsosteotomie]
    Meier R.
    Krimmer H.
    Operative Orthopädie und Traumatologie, 2002, 14 (3) : 205 - 214
  • [23] Does the distal radioulnar joint orientation influence the outcome of ulnar shortening osteotomy: a retrospective study
    Meuser, Stefan
    Ueberberg, Johanna
    Kernich, Nikolaus
    Weber, Carolyn
    Richter, Martin
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2025, 50 (02) : 222 - 227
  • [24] Nonunion Rates Among Ulnar-Shortening Osteotomy for Ulnar Impaction Syndrome: A Systematic Review
    Owens, Jessell
    Compton, Jocelyn
    Day, Molly
    Glass, Natalie
    Lawler, Ericka
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2019, 44 (07): : 612 - +
  • [25] Ulnar Impaction Syndrome: Incidence of Lunotriquetral Ligament Degeneration and Outcome of Ulnar-Shortening Osteotomy
    Iwatsuki, Katsuyuki
    Tatebe, Masahiro
    Yamamoto, Michiro
    Shinohara, Takaaki
    Nakamura, Ryogo
    Hirata, Hitoshi
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2014, 39 (06): : 1108 - 1113
  • [26] Isolated Ulnar Shortening Osteotomy for the Treatment of Extra-Articular Distal Radius Malunion
    Srinivasan, Ramesh C.
    Jain, Deeptee
    Richard, Marc J.
    Leversedge, Fraser J.
    Mithani, Suhail K.
    Ruch, David S.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2013, 38A (06): : 1106 - 1110
  • [27] Results of ulnar shortening osteotomy for ulnocarpal abutment after malunited distal radius fracture
    Tatebe, Masahiro
    Shinohara, Takaaki
    Okui, Nobuyuki
    Yamamoto, Michiro
    Imaeda, Toshihiko
    Hirata, Hitoshi
    ACTA ORTHOPAEDICA BELGICA, 2012, 78 (06): : 714 - 718
  • [28] Evaluation of the metaphyseal ulnar shortening technique according to Sennwald
    Beckers, Joris
    The, Bertram
    Degreef, Ilse
    De Smet, Luc
    ACTA ORTHOPAEDICA BELGICA, 2016, 82 (02): : 280 - 286
  • [29] Outcomes of Ulnar Shortening for Ulnar Impaction Syndrome Using the 2.7 mm AO Ulna Shortening Osteotomy System
    Finnigan, T.
    Makaram, N.
    Baumann, A.
    Ramesh, K.
    Mohil, R.
    Srinivasan, M.
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2018, 23 (01) : 82 - 89
  • [30] Ulnar Shortening Osteotomy for Ulnar-Sided Wrist Pain
    Tatebe, Masahiro
    Nishizuka, Takanobu
    Hirata, Hitoshi
    Nakamura, Ryogo
    JOURNAL OF WRIST SURGERY, 2014, 3 (02) : 77 - 84