Performance improvement of air-source autocascade high-temperature heat pumps using advanced exergy analysis

被引:6
作者
Ma, Xudong [1 ]
Du, Yanjun [1 ]
Wu, Yuting [1 ]
Lei, Biao [1 ]
机构
[1] Beijing Univ Technol, MOE Key Lab Enhanced Heat Transfer & Energy Conser, Beijing Key Lab Heat Transfer & Energy Convers, Beijing 100124, Peoples R China
基金
中国博士后科学基金;
关键词
Industrial decarbonization; High-temperature heat pump; Autocascade heat pump; Advanced exergy analysis; Large temperature rise; MULTIOBJECTIVE OPTIMIZATION; REFRIGERATION SYSTEM; ENERGY; CYCLE; COMPRESSION;
D O I
10.1016/j.energy.2024.132673
中图分类号
O414.1 [热力学];
学科分类号
摘要
Autocascade high-temperature heat pump (AHTHP) have the capacity for significant temperature increases, offering a promising alternative for industrial decarbonization. For a more comprehensive evaluation of the performance improvement potential of an air-source AHTHP, this work proposed a method to select refrigerant blend that has the greatest effect on the performance of an AHTHP by using an advanced exergy analysis. Subsequently, a refrigerant selection for an air-source AHTHP with steam injection technology was performed. The performance enhancement was evaluated under year-round system operating conditions, comparing the selected refrigerant with a refrigerant blend chosen using the conventional thermodynamic method. The results indicate that the refrigerant blend 0.6R245fa/0.4R1234yf, chosen through the advanced exergy analysis, exhibits a more significant capability to enhance heating capacity and output temperature in comparison to the refrigerant 0.5R1233zd(E)/0.5R1234yf, which was chosen through the conventional thermodynamic analysis. When increasing the heating capacity, the average Coefficient of performance (COP) of the refrigerant blend 0.6R245fa/0.4R1234yf at the daily maximum and minimum temperatures increased by 5.60 % and 4.07 %, respectively, while the average power consumption decreased by 6.08 % and 23.81 %, respectively. When increasing the output temperature, the COP difference between the two refrigerant blends is not significant. The average power consumption with 0.6R245fa/0.4R1234yf is 2.19 kW and 2.71 kW at the output temperature is 120 degrees C and 110 degrees C respectively, which is lower than the average power consumption with 0.5R1233zd(E)/ 0.5R1234yf. The results and analysis of this research could provide an effective guidance for enhancing the performance and environmental friendliness of air-source AHTHP.
引用
收藏
页数:13
相关论文
共 58 条
  • [1] [Anonymous], 2024, Shanghai Energy Saving, P363
  • [2] [Anonymous], 2017, Key world energy statistics 2017
  • [3] Parametric assessment and multi-objective optimization of an internal auto-cascade refrigeration cycle based on advanced exergy and exergoeconomic concepts
    Asgari, Sahar
    Noorpoor, A. R.
    Boyaghchi, Fateme Ahmadi
    [J]. ENERGY, 2017, 125 : 576 - 590
  • [4] Vapor injected compression with economizing in packaged air conditioning systems for high temperature climate
    Bahman, Ammar M.
    Ziviani, Davide
    Groll, Eckhard A.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 94 : 136 - 150
  • [5] Advanced exergy analysis on a modified auto-cascade freezer cycle with an ejector
    Bai, Tao
    Yu, Jianlin
    Yan, Gang
    [J]. ENERGY, 2016, 113 : 385 - 398
  • [6] A comprehensive study of a green hybrid multi-generation compressed air energy storage (CAES) system for sustainable cities: Energy, exergy, economic, exergoeconomic, and advanced exergy analysis
    Bushehri, Mehdi Chahabi
    Zolfaghari, Seyed Mohammad
    Soltani, M.
    Nabat, Mohammad Hossein
    Nathwani, Jatin
    [J]. SUSTAINABLE CITIES AND SOCIETY, 2024, 101
  • [7] Energy, exergy, economic and environmental analyses and optimization of a novel vapor injection autocascade heat pump for high-temperature water heating
    Chen, Jiaheng
    Chen, Qi
    Qin, Xiang
    Wang, Dingbiao
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2022, 267
  • [8] Co. SGSP, 2022, Electricity tariff for industrial and commercial users of state grid Shaanxi electric power Co
  • [9] Energy, exergy, and economic (3E) analyses and multi-objective optimization of a cascade absorption refrigeration system for low-grade waste heat recovery
    Cui, Peizhe
    Yu, Mengxiao
    Liu, Zhiqiang
    Zhu, Zhaoyou
    Yang, Sheng
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2019, 184 : 249 - 261
  • [10] Environmental and economical analyses of transcritical CO2 heat pump combined with direct dedicated mechanical subcooling (DMS) for space heating in China
    Dai, Baomin
    Qi, Haifeng
    Liu, Shengchun
    Zhong, Zhifeng
    Li, Hailong
    Song, Mengjie
    Ma, Muyu
    Sun, Zhili
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2019, 198