Myocardial blood flow quantification with SPECT

被引:1
作者
Wells, R. Glenn [1 ]
Small, Gary R. [1 ]
Ruddy, Terrence D. [1 ]
机构
[1] Univ Ottawa Heart Inst, Cardiol, Ottawa, ON, Canada
关键词
Single-photon emission-computed tomography; Myocardial perfusion imaging; Regional blood flow; Cardiovascular disease; Review; CORONARY-ARTERY-DISEASE; DYNAMIC SPECT; PERFUSION RESERVE; N-13-AMMONIA PET; PROGNOSTIC ROLE; GATED SPECT; VALIDATION; CAMERA; OPTIMIZATION; QUANTITATION;
D O I
10.1016/j.jmir.2024.02.016
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: The addition of absolute myocardial blood flow (MBF) data improves the diagnostic and prognostic accuracy of relative perfusion imaging with nuclear medicine. Cardiac-specific gamma cameras allow measurement of MBF with SPECT. Methods: This paper reviews the evidence supporting the use of SPECT to measure myocardial blood flow (MBF). Studies have evaluated SPECT MBF in large animal models and compared it in humans with invasive angiographic measurements and against the clinical standard of PET MBF. The repeatability of SPECT MBF has been determined in both single-site and multi-center trials. Results: SPECT MBF has excellent correlation with microspheres in an animal model, with the number of stenoses and fractional flow reserve, and with PET-derived MBF. The inter-user coefficient of variability is similar to 20% while the COV of test-retest MBF is similar to 30%. SPECT MBF improves the sensitivity and specificity of the detection of multi-vessel disease over relative perfusion imaging and provides incremental value in predicting adverse cardiac events. Conclusion: SPECT MBF is a promising technique for providing clinically valuable information in the assessment of coronary artery disease.
引用
收藏
页码:S51 / S58
页数:8
相关论文
共 63 条
[11]   A fast cardiac gamma camera with dynamic SPECT capabilities: design, system validation and future potential [J].
Bocher, Moshe ;
Blevis, Ira M. ;
Tsukerman, Leonid ;
Shrem, Yigal ;
Kovalski, Gil ;
Volokh, Lana .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (10) :1887-1902
[12]   Accurate and efficient rapid acquisition early post-injection stress-first CZT SPECT myocardial perfusion imaging with tetrofosmin and attenuation correction [J].
Case, James A. ;
Courter, Staci A. ;
McGhie, AIain ;
Patel, Krishna K. ;
Sperry, Brett W. ;
Moloney, Erin ;
Case, Katrina O. ;
Burgett, Eric V. ;
Bateman, Timothy M. .
JOURNAL OF NUCLEAR CARDIOLOGY, 2023, 30 (06) :2644-2654
[13]   Deep-learning-based methods of attenuation correction for SPECT and PET [J].
Chen, Xiongchao ;
Liu, Chi .
JOURNAL OF NUCLEAR CARDIOLOGY, 2023, 30 (05) :1859-1878
[14]   Inter- and Intraobserver Repeatability of Myocardial Flow Reserve Values Determined with SPECT Study Using a Discovery NM530c Camera and Corridor 4DM Software [J].
Cichocki, Pawel ;
Blaszczyk, Michal ;
Cygulska, Kamila ;
Filipczak, Krzysztof ;
Adamczewski, Zbigniew ;
Kusmierek, Jacek ;
Lipiec, Piotr ;
Kasprzak, Jaroslaw Damian ;
Plachcinska, Anna .
JOURNAL OF PERSONALIZED MEDICINE, 2021, 11 (11)
[15]   Improved precision of SPECT myocardial blood flow using a net tracer retention model [J].
Cuddy-Walsh, Sarah G. ;
deKemp, Robert A. ;
Ruddy, Terrence D. ;
Wells, R. Glenn .
MEDICAL PHYSICS, 2023, 50 (04) :2009-2021
[16]   Accuracy and Reproducibility of Myocardial Blood Flow Quantification by Single Photon Emission Computed Tomography Imaging in Patients With Known or Suspected Coronary Artery Disease [J].
de Souza, Ana Carolina do A. H. ;
Harms, Hendrik J. ;
Martell, Laurel ;
Bibbo, Courtney ;
Harrington, Meagan ;
Sullivan, Kyle ;
Hainer, Jon ;
Dorbala, Sharmila ;
Blankstein, Ron ;
Taqueti, Viviany R. ;
Foley Kijewski, Marie ;
Park, Mi-Ae ;
Meretta, Alejandro ;
Breault, Christopher ;
Roth, Nathaniel ;
Poitrasson-Riviere, Alexis ;
Soman, Prem ;
Gullberg, Grant T. ;
Di Carli, Marcelo F. .
CIRCULATION-CARDIOVASCULAR IMAGING, 2022, 15 (06) :E013987
[17]   Quantification of myocardial flow reserve using a gamma camera with solid-state cadmium-zinc-telluride detectors: Relation to angiographic coronary artery disease [J].
de Souza, Ana Carolina do A. H. ;
Goncalves, Bernardo K. D. ;
Tedeschi, Angelo L. ;
Lima, Ronaldo S. L. .
JOURNAL OF NUCLEAR CARDIOLOGY, 2021, 28 (03) :876-884
[18]   Single Photon Emission Computed Tomography (SPECT) Myocardial Perfusion Imaging Guidelines: Instrumentation, Acquisition, Processing, and Interpretation [J].
Dorbala, Sharmila ;
Ananthasubramaniam, Karthik ;
Armstrong, Ian S. ;
Chareonthaitawee, Panithaya ;
DePuey, E. Gordon ;
Einstein, Andrew J. ;
Gropler, Robert J. ;
Holly, Thomas A. ;
Mahmarian, John J. ;
Park, Mi-Ae ;
Polk, Donna M. ;
Russell, Raymond, III ;
Slomka, Piotr J. ;
Thompson, Randall C. ;
Wells, R. Glenn .
JOURNAL OF NUCLEAR CARDIOLOGY, 2018, 25 (05) :1784-1846
[19]   Performance evaluation of D-SPECT: a novel SPECT system for nuclear cardiology [J].
Erlandsson, Kjell ;
Kacperski, Krzysztof ;
van Gramberg, Dean ;
Hutton, Brian F. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (09) :2635-2649
[20]   Validation of a Multimodality Flow Phantom and Its Application for Assessment of Dynamic SPECT and PET Technologies [J].
Gabrani-Juma, Hanif ;
Clarkin, Owen J. ;
Pourmoghaddas, Amir ;
Driscoll, Brandon ;
Wells, R. Glenn ;
deKemp, Robert A. ;
Klein, Ran .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (01) :132-141