Rapid Determination of Acrylamide by HILIC-MS/MS in Selected Food Samples

被引:0
|
作者
Dekic, Sanja [1 ]
Kecojevic, Isidora [2 ]
Bajic, Biljana [2 ]
Joksimovic, Ana [2 ]
Ilic, Mila [3 ]
Lolic, Aleksandar [4 ]
Baosic, Rada [4 ]
机构
[1] Anal doo, Japanska 4, Belgrade 11070, Serbia
[2] Bio Tech Lab doo, Vojvode Putnika 87, Sremska Kamenica 21208, Serbia
[3] Univ Belgrade, Inst Chem Technol & Met, POB 473,Njegoseva 12, Belgrade, Serbia
[4] Univ Belgrade, Fac Chem, Studentski Trg 12-16, Belgrade, Serbia
关键词
Acrylamide; QuEChERS; HILIC-MS/MS; Bread samples; Infant food; TANDEM MASS-SPECTROMETRY; INTERACTION LIQUID-CHROMATOGRAPHY;
D O I
10.1007/s12161-024-02676-9
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
A simple, rapid, and robust hydrophilic interaction liquid chromatography-tandem mass spectrometry method has been applied for the determination of acrylamide in bread, potato-based heat-processed products, and cereal-based infant food. The QuEChERS methodology was used for sample extraction and clean-up. Enzyme asparaginase was used to prepare an acrylamide-free bread-like matrix, thereby eliminating the lack of acrylamide-free food matrices as one of the limitations for method development and validation. The obtained linear range was 10-2500 mu g/kg, and the limit of detection and the limit of quantification were 2.71 and 10.0 mu g/kg (S/N = 3 and 10, respectively). The developed method demonstrated good recoveries (98.9-102.8%), intra-day (2.1-3.8%), and inter-day precision (2.9-4.0%). The acrylamide was found in all samples; the concentrations were lower than benchmark levels set by the European Union. In the baby food sample, the AA concentrations were below the limit of quantification (10 mu g/kg), and the benchmark level set by the European Union is 40 mu g/kg.
引用
收藏
页码:1540 / 1549
页数:10
相关论文
共 50 条
  • [31] Development and validation of a HILIC-MS/MS method for quantification of decitabine in human plasma by using lithium adduct detection
    Hua, Wenyi
    Ierardi, Thomas
    Lesslie, Michael
    Hoffman, Brian T.
    Mulvana, Daniel
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 969 : 117 - 122
  • [32] Sample Preparation Strategies for the Effective Quantitation of Hydrophilic Metabolites in Serum by Multi-Targeted HILIC-MS/MS
    Tsakelidou, Elisavet
    Virgiliou, Christina
    Valianou, Lemonia
    Gika, Helen G.
    Raikos, Nikolaos
    Theodoridis, Georgios
    METABOLITES, 2017, 7 (02):
  • [33] Capillary HILIC-MS: A New Tool for Sensitive Top-Down Proteomics
    Gargano, Andrea F. G.
    Roca, Liana S.
    Fellers, Ryan T.
    Bocxe, Max
    Dominguez-Vega, Elena
    Somsen, Govert W.
    ANALYTICAL CHEMISTRY, 2018, 90 (11) : 6601 - 6609
  • [34] A rapid and easy method based on hydrophilic interaction chromatography coupled with tandem mass spectrometry (HILIC-MS/MS/MS) to quantify iodinated X-ray contrast in wastewaters
    Sordet, Martin
    Bulete, Audrey
    Vulliet, Emmanuelle
    TALANTA, 2018, 190 : 480 - 486
  • [35] HILIC-MS/MS method development for targeted quantitation of metabolites: Practical considerations from a clinical diagnostic perspective
    Rappold, Brian A.
    Grant, Russell P.
    JOURNAL OF SEPARATION SCIENCE, 2011, 34 (24) : 3527 - 3537
  • [36] Development and evaluation of a HILIC-MS method for the determination of amino acid and non-amino acid impurities in histidine
    Xu, Qun
    Tadjimukhamedov, Fatkhulla K.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2022, 219
  • [37] A HILIC-MS/MS assay for the quantification of metformin and sitagliptin in human plasma and urine: A tool for studying drug transporter perturbation
    Scherf-Clavel, Oliver
    Kinzig, Martina
    Stoffel, Marc S.
    Fuhr, Uwe
    Soergel, Fritz
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 175
  • [38] Rapid sample preparation method for LC-MS/MS or GC-MS analysis of acrylamide in various food matrices
    Mastovska, Katerina
    Lehotay, Steven J.
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2006, 54 (19) : 7001 - 7008
  • [39] A simple, versatile, and automated pulse-diffusion-focusing strategy for sensitive milliliter-level-injection HILIC-MS/MS analysis of hydrophilic toxins
    Long, Fei
    Zhang, Mei
    Yuan, Jiahao
    Du, Juan
    Ma, Ande
    Pan, Jialiang
    JOURNAL OF HAZARDOUS MATERIALS, 2020, 392 (392)
  • [40] Development and method validation for determination of acrylamide in food by modified QuEChERS and UHPLC-MS/MS analysis
    Cossu, Maurizio
    Sanna, Andrea
    Ledda, Giuseppe
    Chessa, Giannina
    Mangano, Giuseppe
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2024, 135