Comparison of Intraosseous Temperature Rise in Different Surgical Guide Systems: An In Vitro Study

被引:0
作者
Uckun, Gozde Gokce [1 ]
Saygili, Sina [2 ]
Sulun, Tonguc [2 ]
Cankaya, Abdulkadir Burak [3 ]
机构
[1] Sakarya Univ, Fac Dent, Dept Oral & Maxillofacial Surg, TR-34452 Sakarya, Turkiye
[2] Istanbul Univ, Fac Dent, Dept Prosthodont, Istanbul, Turkiye
[3] Istanbul Univ, Fac Dent, Dept Oral & Maxillofacial Surg, Istanbul, Turkiye
关键词
Dental implant; Surgical guide; Bone necrosis; Guide design; Thermal damage; IMPLANT SITE PREPARATION; HEAT-GENERATION; IRRIGATION CHANNEL; DRILL GUIDE; BONE; TEMPLATE; SURGERY;
D O I
10.1177/23202068241284084
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: This study proposes to investigate the influence of various surgical guide designs on the generation temperature in the cortical and cancellous regions of the osteotomy site. The working hypothesis was that open guides are more efficacious in controlling excessive heat generation in cortical and cancellous areas.Materials and Methods: Implant osteotomy was performed on specimens simulating D3 bone density using surgical guides produced with three different designs: an open guide, a guide with an external cooling channel, and a closed guide. Temperature increases occurring in the cortical layer from a depth of 2 mm and in the cancellous layer from a depth of 10 mm were measured with type K thermocouples.Results: Temperature averages recorded from a depth of 2 mm during osteotomy show statistically significant differences between groups (p = .003). The temperature rise in the group using a closed surgical guide was significantly higher than in the groups using an open surgical guide and a surgical guide with an external cooling channel on the cortical layer, while the temperature increase did not show any significant difference in both cortical and cancellous layers between the open guide and guide with external cooling channel. Temperature averages recorded from a depth of 10 mm do not show statistically significant differences between groups (p = .054).Conclusion: Using open surgical guides or surgical guides with external cooling channels among the guided surgical systems is a more reliable way to keep the thermal increase under control.
引用
收藏
页码:219 / 227
页数:9
相关论文
共 27 条
[1]   The impact of surgical guide design and bone quality on heat generation during pilot implant site preparation: an in vitro study [J].
Abuhajar, Eman ;
Salim, Nesreen A. ;
Sallam, Malik ;
Jarab, Fadi ;
Satterthwaite, Julian D. .
BMC ORAL HEALTH, 2023, 23 (01)
[2]   Guided Implant Placement Using an Internally Cooling Surgical Template: A Technical Note [J].
Alevizakos, Vasilios ;
Mitov, Gergo ;
von See, Constantin .
JOURNAL OF ORAL IMPLANTOLOGY, 2020, 46 (05) :533-536
[3]   Effect of Guiding Sleeve Design on Intraosseous Heat Generation During Implant Site Preparation (In Vitro Study) [J].
Ashry, Amal ;
Elattar, Mohamed Sherine ;
Elsamni, Osama Ahmed ;
Soliman, Ingy Saied .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (02) :147-154
[4]   Effect of the Combination of Low-Speed Drilling and Cooled Irrigation Fluid on Intraosseous Heat Generation During Guided Surgical Implant Site Preparation: An In Vitro Study [J].
Barrak, Ibrahim ;
Joo-Fancsaly, Arpad ;
Varga, Endre ;
Boa, Kristof ;
Piffko, Jozsef .
IMPLANT DENTISTRY, 2017, 26 (04) :541-546
[5]   External cooling efficiently controls intraosseous temperature rise caused by drilling in a drilling guide system: an in vitro study [J].
Boa, Kristof ;
Varga, Endre, Jr. ;
Pinter, Gabor ;
Csonka, Akos ;
Gargyan, Istvan ;
Varga, Endre .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2015, 53 (10) :963-967
[6]   Osseointegration in relation to drilling speed in the preparation of dental implants sites: A systematic review [J].
Celles, Cicero Andrade Sigiliao ;
Ferreira, Izabela ;
Valente, Mariana da Lima da Costa ;
dos Reis, Andrea Candido .
JOURNAL OF PROSTHETIC DENTISTRY, 2025, 133 (02) :394-401
[7]   Current state of the art of computer-guided implant surgery [J].
D'haese, Jan ;
Ackhurst, Johan ;
Wismeijer, Daniel ;
De Bruyn, Hugo ;
Tahmaseb, Ali .
PERIODONTOLOGY 2000, 2017, 73 (01) :121-133
[8]   Guided Implant Surgery: What Is the Influence of This New Technique on Bone Cell Viability? [J].
dos Santos, Pamela Leticia ;
Queiroz, Thallita Pereira ;
Margonar, Rogerio ;
Gomes de Souza Carvalho, Abrahao Cavalcante ;
Okamoto, Roberta ;
de Souza Faloni, Ana Paula ;
Garcia Junior, Idelmo Rangel .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2013, 71 (03) :505-512
[9]   Influence of Drilling Technique on the Radiographic, Thermographic, and Geomorphometric Effects of Dental Implant Drills and Osteotomy Site Preparations [J].
Fraguas de San Jose, Lara ;
Ruggeri, Filippo Maria ;
Rucco, Roberta ;
Zubizarreta-Macho, Alvaro ;
Alonso Perez-Barquero, Jorge ;
Riad Deglow, Elena ;
Hernandez Montero, Sofia .
JOURNAL OF CLINICAL MEDICINE, 2020, 9 (11)
[10]   Comparison of heat generation between guided and conventional implant surgery for single and sequential drilling protocols-An in vitro study [J].
Froesch, Leonie ;
Mukaddam, Khaled ;
Filippi, Andreas ;
Zitzmann, Nicola U. ;
Kuehl, Sebastian .
CLINICAL ORAL IMPLANTS RESEARCH, 2019, 30 (02) :121-130