Simultaneous smartphone-based colorimetric determination of melamine and sodium hypochlorite in milk samples using a simple microfluidic kit

被引:1
作者
Solgi, Mahtab [1 ]
Afkhami, Abbas [1 ,2 ]
Madrakian, Tayyebeh [1 ]
Khalili, Sina [1 ]
Sarvestani, Mohammad Reza Jalali [1 ]
机构
[1] Bu Ali Sina Univ, Fac Chem & Petr Sci, Dept Analyt Chem, Hamadan 6517838695, Iran
[2] D 8 Int Univ, Hamadan, Iran
关键词
Microfluidic; Colorimetry; Smartphone; Melamine; Sodium hypochlorite; Simultaneous determination; ACID; TOXICITY;
D O I
10.1007/s11694-024-02877-0
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
This research introduced a microfluidic kit for rapid and economic detection of melamine (MLM) and sodium hypochlorite (NaOCl) in milk samples. The kit allows for simultaneous identification of MLM and NaOCl by reacting with cyanuric acid-modified Au nanoparticles (Au@Ca) and N, N-diethyl-p-phenylenediamine, respectively. The resulting color changes are used as the analytical signal for detection. All of the effective operational parameters were optimized by a one-factor-at-a-time approach. Under the optimum conditions (pH 6.5, path length = 50 mm, flow rate = 0.1 ml/min) a linear relationship between the concentrations of MLM and NaOCl and the blue component of the analyzed RGB pixels of the images captured with a smartphone camera was observed. The linear ranges for MLM and NaOCl were obtained in the concentration ranges of 0.1-1 and 0.1-4.5 mu M, respectively, with 0.040 mu M and 0.078 mu M detection limits, consecutively. The results indicate that the proposed microfluidic kit provides strong selectivity and high reproducibility for detecting MLM and NaOCl in milk samples. To validate the performance of the method, the microfluidic kit was employed for analyzing five different milk samples, yielding recovery values between 94.0% and 105.0% and relative standard deviation values lower than 4.12% indicating the proposed system has admissible accuracy for both analytes. Besides, the results were compared to those obtained using high-performance liquid chromatography, as a standard reference method, and a good agreement between the two approaches was found.
引用
收藏
页码:9271 / 9279
页数:9
相关论文
共 35 条
[1]   Microfluidic analytical systems for food analysis [J].
Atalay, Yegermal T. ;
Vermeir, Steven ;
Witters, Daan ;
Vergauwe, Nicolas ;
Verbruggen, Bert ;
Verboven, Pieter ;
Nicolai, Bart M. ;
Lammertyn, Jeroen .
TRENDS IN FOOD SCIENCE & TECHNOLOGY, 2011, 22 (07) :386-404
[2]   Smartphone-based colorimetric detection system for portable health tracking [J].
Balbach, Samira ;
Jiang, Nan ;
Moreddu, Rosalia ;
Dong, Xingchen ;
Kurz, Wolfgang ;
Wang, Congyan ;
Dong, Jie ;
Yin, Yixia ;
Butt, Haider ;
Brischwein, Martin ;
Hayden, Oliver ;
Jakobi, Martin ;
Tasoglu, Savas ;
Koch, Alexander W. ;
Yetisen, Ali K. .
ANALYTICAL METHODS, 2021, 13 (38) :4361-4369
[3]   A paired emitter-detector diode-based photometer for the determination of sodium hypochlorite adulteration in milk [J].
Bastan, Narges ;
Ahmadi, Mazaher ;
Madrakian, Tayyebeh ;
Afkhami, Abbas ;
Khalili, Sina ;
Majidi, Mohsen ;
Moradi, Mohammadreza .
SCIENTIFIC REPORTS, 2023, 13 (01)
[4]   Recent Advances in Microfluidic Technology for Bioanalysis and Diagnostics [J].
Berlanda, Simon F. ;
Breitfeld, Maximilian ;
Dietsche, Claudius L. ;
Dittrich, Petra S. .
ANALYTICAL CHEMISTRY, 2021, 93 (01) :311-331
[5]   PhotoMetrix and colorimetric image analysis using smartphones [J].
Bock, Fernanda Carla ;
Helfer, Gilson Augusto ;
Ben da Costa, Adilson ;
Dessuy, Morgana Bazzan ;
Ferrao, Marco Flores .
JOURNAL OF CHEMOMETRICS, 2020, 34 (12)
[6]   Improved analytical performance of smartphone-based colorimetric analysis by using a power-free imaging box [J].
Chen, Gang ;
Fang, Can ;
Chai, Hui Hui ;
Zhou, Ying ;
Li, Wan Yun ;
Yu, Ling .
SENSORS AND ACTUATORS B-CHEMICAL, 2019, 281 :253-261
[7]   Determination of glucose and uric acid with bienzyme colorimetry on microfluidic paper-based analysis devices [J].
Chen, Xi ;
Chen, Jin ;
Wang, Fubin ;
Xiang, Xia ;
Luo, Ming ;
Ji, Xinghu ;
He, Zhike .
BIOSENSORS & BIOELECTRONICS, 2012, 35 (01) :363-368
[8]   Toxicity of Melamine: The Public Health Concern [J].
Chu, C. Y. ;
Wang, C. C. .
JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART C-ENVIRONMENTAL CARCINOGENESIS & ECOTOXICOLOGY REVIEWS, 2013, 31 (04) :342-386
[9]   Cell phone based colorimetric analysis for point-of-care settings [J].
Coleman, Benjamin ;
Coarsey, Chad ;
Asghar, Waseem .
ANALYST, 2019, 144 (06) :1935-1947
[10]   Paper-based microfluidic devices: Fabrication, detection, and significant applications in various fields [J].
Das, Shibam ;
Gagandeep ;
Bhatia, Rohit .
REVIEWS IN ANALYTICAL CHEMISTRY, 2022, 41 (01) :112-136