Quantification of Neutron-Induced Single-Event Upsets in a Static Random-Access Memory by Clinical High-Energy Photon Beam

被引:0
作者
Gabrisch, Lukas [1 ,2 ]
Cecchetto, Matteo [3 ]
Delfs, Bjoern [1 ,2 ]
Looe, Hui Khee [1 ,2 ]
Budroweit, Jan [4 ]
Alia, Ruben Garcia [3 ]
Poppe, Bjoern [1 ,2 ]
Wyrwoll, Vanessa [1 ,2 ]
机构
[1] Carl von Ossietzky Univ Oldenburg, Univ Clin Med Radiat Phys, Med Campus Pius Hosp, D-26129 Oldenburg, Germany
[2] Pius Hosp Oldenburg, D-26121 Oldenburg, Germany
[3] CERN, CH-1211 Geneva, Switzerland
[4] German Aerosp Ctr DLR, D-28359 Bremen, Germany
关键词
Neutrons; Photonics; Linear particle accelerator; Random access memory; Single event upsets; Detectors; Radiation effects; FLUKA; Monte Carlo (MC) simulation; neutrons; single-event effects (SEEs); ACCELERATOR; FLUENCE; SPECTRA; SIEMENS;
D O I
10.1109/TNS.2024.3427773
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The possibility of using calibrated static random-access memory (SRAM) memory for the quantification of neutron fluence in a radiotherapy facility for cancer treatment utilizing a high-energy 15-MV photon beam (Bremsstrahlung) from an electron linear accelerator has been exploited in this work. This has been performed by varying the field size of the photon beam and the positioning of the SRAM memory at three different positions in relation to the isocenter of the beam. The measurements demonstrated that neutrons originating from interactions between the high-energy photons and accelerator parts with high-Z materials are able to induce single-event upsets (SEUs) in the SRAM memory, where the measured SEUs depend on the measurement location. Monte Carlo (MC) simulations have been performed to retrieve the neutron fluence under each investigated measurement condition. Using the simulated neutron fluence differential in energy and the interactions cross sections determined previously, the expected SEUs were computed. The comparison between measured and simulated SEUs normalized to the linear accelerators (linac) output shows acceptable agreement within the experimental uncertainties. As exposure to secondary neutrons poses a risk to all patients, especially the ones with pacemakers or other electronical aids, the feasibility of establishing the neutron fluence through SEU quantification in an SRAM device provides new opportunities to estimate the associated risk in a clinical environment. Further work can be performed to investigate the correlation between the high-Z linac components and the neutron fluence during patient irradiation to better comprehend the variation between different linac types and manufacturers.
引用
收藏
页码:1503 / 1510
页数:8
相关论文
共 22 条
  • [1] Direct Ionization Impact on Accelerator Mixed-Field Soft-Error Rate
    Alia, Ruben Garcia
    Tali, Maris
    Brugger, Markus
    Cecchetto, Matteo
    Cerutti, Francesco
    Cononetti, Andrea
    Danzeca, Salvatore
    Esposito, Luigi
    Fernandez-Martinez, Pablo
    Gilardoni, Simone
    Infantino, Angelo
    Kastriotou, Maria
    Kerboub, Nourdine
    Lerner, Giuseppe
    Wyrwoll, Vanessa
    Ferlet-Cavrois, Veronique
    Boatella, Cesar
    Javanainen, Arto
    Kettunen, Heikki
    Morilla, Yolanda
    Martin-Holgado, Pedro
    Gaillard, Remi
    Wrobel, Frederic
    Cazzaniga, Carlo
    Alexandrescu, Dan
    Glorieux, Maximilien
    Puchner, Helmut
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2020, 67 (01) : 345 - 352
  • [2] [Anonymous], 2009, FLAIR: A Powerful but User Friendly Graphical Inter-face for FLUKA
  • [3] [Anonymous], 2008, document6800-2
  • [4] Overview of the FLUKA code
    Battistoni, Giuseppe
    Boehlen, Till
    Cerutti, Francesco
    Chin, Pik Wai
    Esposito, Luigi Salvatore
    Fasso, Alberto
    Ferrari, Alfredo
    Lechner, Anton
    Empl, Anton
    Mairani, Andrea
    Mereghetti, Alessio
    Ortega, Pablo Garcia
    Ranft, Johannes
    Roesler, Stefan
    Sala, Paola R.
    Vlachoudis, Vasilis
    Smirnov, George
    [J]. ANNALS OF NUCLEAR ENERGY, 2015, 82 : 10 - 18
  • [5] Spectral distribution of particle fluence in small field detectors and its implication on small field dosimetry
    Benmakhlouf, Hamza
    Andreo, Pedro
    [J]. MEDICAL PHYSICS, 2017, 44 (02) : 713 - 724
  • [6] The FLUKA Code: Developments and Challenges for High Energy and Medical Applications
    Boehlen, T. T.
    Cerutti, F.
    Chin, M. P. W.
    Fosso, A.
    Ferrari, A.
    Ortega, P. G.
    Mairani, A.
    Sala, P. R.
    Smirnov, G.
    Vlachoudisl, V.
    [J]. NUCLEAR DATA SHEETS, 2014, 120 : 211 - 214
  • [7] The influence of field size and off-axis distance on photoneutron spectra of the 18 MV Siemens Oncor linear accelerator beam
    Brkic, Hrvoje
    Ivkovic, Ana
    Kasabasic, Mladen
    Sovilj, Marina Poje
    Jurkovic, Slaven
    Stimac, Damir
    Rubin, Otmar
    Faj, Dario
    [J]. RADIATION MEASUREMENTS, 2016, 93 : 28 - 34
  • [8] Cecchetto M., 2021, Ph.D. dissertation
  • [9] Electronics Irradiation With Neutrons at the NEAR Station of the nTOF Spallation Source at CERN
    Cecchetto, Matteo
    Barbero, Mario Sacristan
    Lerner, Giuseppe
    Alia, Ruben Garcia
    Aguiar, Ygor
    Senajova, Dominika
    Infantes, Francisco Garcia
    Rodriguez, Jose Antonio Pavon
    Gilarte, Marta Sabate
    Vlachoudis, Vasilis
    Bernardes, Ana-Paula
    Calviani, Marco
    Danzeca, Salvatore
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2023, 70 (08) : 1587 - 1595
  • [10] 0.1-10 MeV Neutron Soft Error Rate in Accelerator and Atmospheric Environments
    Cecchetto, Matteo
    Alia, Ruben Garcia
    Wrobel, Frederic
    Coronetti, Andrea
    Bilko, Kacper
    Lucsanyi, David
    Fiore, Salvatore
    Bazzano, Giulia
    Pirovano, Elisa
    Nolte, Ralf
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2021, 68 (05) : 873 - 883