Utilizing multiclassifier radiomics analysis of ultrasound to predict high axillary lymph node tumour burden in node-positive breast cancer patients: a multicentre study

被引:1
|
作者
Wu, Jiangfeng [1 ]
Ge, Lifang [1 ]
Guo, Yinghong [1 ]
Xu, Dong [2 ]
Wang, Zhengping [1 ]
机构
[1] Wenzhou Med Univ, Affiliated Dongyang Hosp, Dongyang Peoples Hosp, Dept Ultrasound, 60 Wuning West Rd, Dongyang 322100, Zhejiang, Peoples R China
[2] Chinese Acad Sci, Zhejiang Canc Hosp, Inst Basic Med & Canc, Dept Ultrasound,Canc Hosp,Univ Chinese Acad Sci, Hangzhou, Peoples R China
关键词
Axillary lymph node; tumour burden; ultrasound; radiomics; breast cancer; INTERNATIONAL EXPERT CONSENSUS; PRIMARY THERAPY; BIOPSY; MANAGEMENT; SELECTION; SURGERY; SYSTEM;
D O I
10.1080/07853890.2024.2395061
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundThe tumor burden within the axillary lymph nodes (ALNs) constitutes a pivotal factor in breast cancer, serving as the primary determinant for treatment decisions and exhibiting a close correlation with prognosis.ObjectiveThis study aimed to investigate the potential of ultrasound-based radiomics and clinical characteristics in non-invasively distinguishing between low tumor burden (1-2 positive nodes) and high tumor burden (more than 2 positive nodes) in patients with node-positive breast cancer.MethodsA total of 215 patients with node-positive breast cancer, who underwent preoperative ultrasound examinations, were enrolled in this study. Among these patients, 144 cases were allocated to the training set, 37 cases to the validation set, and 34 cases to the testing set. Postoperative histopathology was used to determine the status of ALN tumor burden. The region of interest for breast cancer was delineated on the ultrasound image. Nine models were developed to predict high ALN tumor burden, employing a combination of three feature screening methods and three machine learning classifiers. Ultimately, the optimal model was selected and tested on both the validation and testing sets. In addition, clinical characteristics were screened to develop a clinical model. Furthermore, Shapley additive explanations (SHAP) values were utilized to provide explanations for the machine learning model.ResultsDuring the validation and testing sets, the models demonstrated area under the curve (AUC) values ranging from 0.577 to 0.733 and 0.583 to 0.719, and accuracies ranging from 64.9% to 75.7% and 64.7% to 70.6%, respectively. Ultimately, the Boruta_XGB model, comprising five radiomics features, was selected as the final model. The AUC values of this model for distinguishing low from high tumor burden were 0.828, 0.715, and 0.719 in the training, validation, and testing sets, respectively, demonstrating its superiority over the clinical model.ConclusionsThe developed radiomics models exhibited a significant level of predictive performance. The Boruta_XGB radiomics model outperformed other radiomics models in this study.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Different outcome in node-positive breast cancer patients found by axillary ultrasound or sentinel node procedure
    Nicole C. Verheuvel
    Adri C. Voogd
    Vivianne C. G. Tjan-Heijnen
    S. Siesling
    Rudi M. H. Roumen
    Breast Cancer Research and Treatment, 2017, 165 : 555 - 563
  • [22] Outcomes of sentinel lymph node-positive breast cancer patients after mastectomy with or without axillary lymph node dissection
    Matsumoto, A.
    Umemoto, Y.
    Yoshikawa, M.
    Jinno, H.
    EUROPEAN JOURNAL OF CANCER, 2018, 92 : S71 - S72
  • [23] Different outcome in node-positive breast cancer patients found by axillary ultrasound or sentinel node procedure
    Verheuvel, Nicole C.
    Voogd, Adri C.
    Tjan-Heijnen, Vivianne C. G.
    Siesling, S.
    Roumen, Rudi M. H.
    BREAST CANCER RESEARCH AND TREATMENT, 2017, 165 (03) : 555 - 563
  • [24] Comparison of Sentinel Lymph Node Biopsy Alone and Completion Axillary Lymph Node Dissection for Node-Positive Breast Cancer
    Bilimoria, Karl Y.
    Bentrem, David J.
    Hansen, Nora M.
    Bethke, Kevin P.
    Rademaker, Alfred W.
    Ko, Clifford Y.
    Winchester, David P.
    Winchester, David J.
    JOURNAL OF CLINICAL ONCOLOGY, 2009, 27 (18) : 2946 - 2953
  • [25] MRI-Based Radiomics Nomogram: Prediction of Axillary Non-Sentinel Lymph Node Metastasis in Patients With Sentinel Lymph Node-Positive Breast Cancer
    Qiu, Ya
    Zhang, Xiang
    Wu, Zhiyuan
    Wu, Shiji
    Yang, Zehong
    Wang, Dongye
    Le, Hongbo
    Mao, Jiaji
    Dai, Guochao
    Tian, Xuwei
    Zhou, Renbing
    Huang, Jiayi
    Hu, Lanxin
    Shen, Jun
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [26] Accuracy of ultrasonographic changes during neoadjuvant chemotherapy to predict axillary lymph node response in clinical node-positive breast cancer patients
    Li, Zhuoxuan
    Tong, Yiwei
    Chen, Xiaosong
    Shen, Kunwei
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [27] Machine learning-driven ultrasound radiomics for assessing axillary lymph node burden in breast cancer
    Wang, Si-Rui
    Tian, Feng
    Zhu, Tong
    Cao, Chun-Li
    Wang, Jin-Li
    Li, Wen-Xiao
    Li, Jun
    Hou, Ji-Xue
    FRONTIERS IN ENDOCRINOLOGY, 2025, 16
  • [28] Nomograms predict survival of patients with lymph node-positive, luminal a breast cancer
    Yilun Li
    Li Ma
    BMC Cancer, 21
  • [29] Nomograms predict survival of patients with lymph node-positive, luminal a breast cancer
    Li, Yilun
    Ma, Li
    BMC CANCER, 2021, 21 (01)
  • [30] Extranodular extension in sentinel lymph node-positive breast cancer might predict further initiation of completion axillary lymph node dissection
    Altundag, Kadri
    BREAST CANCER RESEARCH AND TREATMENT, 2019, 173 (02) : 485 - 485