Effect of a 3-second Off-label Exposure on the Depth of Cure of Eight Resin-based Composites

被引:1
作者
Ribeiro, M. T. H. [1 ]
Maucoski, C. [2 ]
Price, R. B. [3 ]
Soares, C. J. [4 ]
机构
[1] Univ Fed Uberlandia, Dent Sch, Dept Operat Dent & Dent Mat, Uberlandia, MG, Brazil
[2] Fed Univ Ponta Grossa, Dent Sch, Dept Operat Dent & Dent Mat, Ponta Grossa, PR, Brazil
[3] Dalhousie Univ, Dept Dent Clin Sci, Halifax, NS, Canada
[4] Univ Fed Uberlandia, Biomech Res Ctr, Dept Operat Dent & Dent Mat, Uberlandia, MG, Brazil
关键词
BULK-FILL; CURING PROFILE; LIGHT; POLYMERIZATION; RESTORATIONS; INTEGRITY; SHRINKAGE; TIME;
D O I
10.2341/23-155-L
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: This study evaluated the depth of cure (DoC) of eight resin-based composites (RBCs) photocured using one multipeak light-curing unit (LCU) on the standard output setting for the manufacturer's RBC recommended exposure time and at a higher irradiance for 3 seconds. Methods: Three conventional RBCs: Tetric EvoCeram (Evo), Tetric N-Ceram (Cer), Tetric Prime (Pri); and five bulk-fill: Tetric N-Ceram Bulk Fill (CerBF), Opus Bulk Fill APS (OpusBF), Opus Bulk Fill Flow APS (OpusF), Tetric PowerFill (PFill) and Tetric PowerFlow (PFlow) were examined. Only PFill and PFlow are formulated to be in 3 seconds. The RBCs were packed into a metal mold and photocured using a Bluephase PowerCure LCU for the RBC manufacturer's recommended exposure time on the standard mode and using the 3-second high irradiance mode. After photocuring, the specimens were immersed in a solvent for 1 hour. The length of the remaining RBC was measured and divided by 2. Data were analyzed using two-way analysis of variance (ANOVA) followed by the Tukey post hoc multiple comparison test (alpha=0.05). alpha =0.05). Results: There was no significant difference in the DoC values for PFill and PFlow when photocured using the 3-second high irradiance protocol compared to the lower irradiance standard mode protocol. All other RBCs had significantly lower DoC values (p<0.001) p< 0.001) when photocured off-label using the 3-second high irradiance mode. Conclusion: Of the eight RBCs tested, only PFill and PFlow achieved the same DoC when the high irradiance 3-second curing method was used compared to when their longer lower irradiance protocol was used.
引用
收藏
页码:421 / 431
页数:11
相关论文
共 53 条
  • [1] Effect of Mold Type and Diameter on the Depth of Cure of Three Resin-Based Composites
    AlShaafi, M. M.
    AlQussier, A.
    AlQahtani, M. Q.
    Price, R. B.
    [J]. OPERATIVE DENTISTRY, 2018, 43 (05) : 520 - 529
  • [2] AlShaafi MM, 2017, SAUDI DENT J, V29, P48, DOI 10.1016/j.sdentj.2017.01.002
  • [3] Effect of a broad-spectrum LED curing light on the Knoop microhardness of four posterior resin based composites at 2, 4 and 6-mm depths
    ALShaafi, Maan M.
    Haenel, Thomas
    Sullivan, Braden
    Labrie, Daniel
    Alqahtani, Mohammed Q.
    Price, Richard B.
    [J]. JOURNAL OF DENTISTRY, 2016, 45 : 14 - 18
  • [4] AMID, 2021, Monet Laser Curing Light
  • [5] The 1 second revolution
  • [6] Effect of Using Manufacturer-recommended Exposure Times to Photo-activate Bulk-fill and Conventional Resin-based Composites
    Barcelos, L. M.
    Braga, S. S. L.
    Pereira, R. A. S.
    Price, R. B.
    Soares, C. J.
    [J]. OPERATIVE DENTISTRY, 2023, 48 (03) : 304 - 316
  • [7] Bicalho A A, 2014, Oper Dent, V39, pE83, DOI 10.2341/12-442-L
  • [8] Effect of the Sample Preparation and Light-curing Unit on the Microhardness and Degree of Conversion of Bulk-fill Resin-based Composite Restorations
    Braga, S. S. L.
    Schettini, A. C. T.
    Carvalho, E. L. O.
    Shimokawa, C. A. K.
    Price, R. B.
    Soares, C. J.
    [J]. OPERATIVE DENTISTRY, 2022, 47 (02) : 163 - 172
  • [9] British Dental Association, 2024, Dental amalgam
  • [10] Light transmittance and micro-mechanical properties of bulk fill vs. conventional resin based composites
    Bucuta, Stefan
    Ilie, Nicoleta
    [J]. CLINICAL ORAL INVESTIGATIONS, 2014, 18 (08) : 1991 - 2000