Electroanalytical sensing of antidiabetic drug linagliptin by using square-wave voltammetry on the boron-doped diamond electrode

被引:2
|
作者
Barzani, Hemn A. H. [1 ]
Ali, Hoshyar Saadi [2 ]
Yardim, Yavuz [3 ]
机构
[1] Lebanese French Univ, Coll Hlth Sci, Dept Med Lab Sci, Erbil, Iraq
[2] Knowledge Univ, Coll Sci, Dept Med Lab Sci, Kirkuk 44001, Erbil, Iraq
[3] Van Yuzuncu Yil Univ, Fac Pharm, Dept Analyt Chem, TR-65080 Van, Turkiye
来源
MONATSHEFTE FUR CHEMIE | 2024年 / 155卷 / 10期
关键词
Linagliptin; Electrochemical sensing; Square-wave voltammetry; Boron-doped diamond electrode; Drug formulations; ELECTROCHEMICAL DETERMINATION; DOSAGE FORM; PHARMACEUTICALS; SURFACTANT; HPLC;
D O I
10.1007/s00706-024-03229-w
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This research paper presents an electroanalytical investigation utilizing voltammetry to quantify the antidiabetic drug linagliptin with an unmodified boron-doped diamond electrode. Using cyclic voltammetry, linagliptin exhibited a single, distinct, irreversible oxidation peak at around + 1.03 V (vs. Ag/AgCl) in a 0.1 mol dm-3 phosphate buffer solution at pH 7.4. The square-wave voltammetry technique achieved acceptable linearity at approximately + 0.94 V in PBS (pH 7.4). The methodology demonstrated linearity within the concentration range of 1.0 and 50.0 mu g cm-3 (equivalent to 2.1 x 10-6-1.1 x 10-4 mol dm-3) and yielded a limit of detection of 0.28 mu g cm-3 (equivalent to 5.9 x 10-7 mol dm-3). The investigation of the proposed method's applicability was ultimately conducted through the sensing of linagliptin in drug formulations. The established methodologies can serve as viable alternatives to other analytical techniques due to their cost-effectiveness, user-friendliness, efficiency, and ability to yield reliable and repeatable results.
引用
收藏
页码:927 / 935
页数:9
相关论文
共 50 条
  • [21] Square-wave voltammetric determination of propranolol and atenolol in pharmaceuticals using a boron-doped diamond electrode
    Sartori, Elen Romao
    Medeiros, Roberta Antigo
    Rocha-Filho, Romeu C.
    Fatibello-Filho, Orlando
    TALANTA, 2010, 81 (4-5) : 1418 - 1424
  • [22] Sensing ivacaftor accomplished using the square-wave voltammetric technique with the assistance of a cationic surfactant on a boron-doped diamond electrode
    Barzani, Hemn A. H.
    Ali, Hoshyar Saadi
    Yunusoglu, Oruc
    Yardim, Yavuz
    DIAMOND AND RELATED MATERIALS, 2024, 144
  • [23] Highly Selective Electrochemical Determination of Phlorizin Using Square Wave Voltammetry at a Boron-Doped Diamond Electrode
    Eda Mehmeti
    Dalibor M. Stanković
    Astrid Ortner
    Janez Zavašnik
    Kurt Kalcher
    Food Analytical Methods, 2017, 10 : 3747 - 3752
  • [24] Quantification of ferulic acid using square-wave voltammetric method at an unmodified boron-doped diamond electrode
    Pınar Talay Pınar
    Hemn A. H. Barzani
    Hoshyar Saadi Ali
    Yavuz Yardım
    Monatshefte für Chemie - Chemical Monthly, 2023, 154 : 1225 - 1233
  • [25] Electroanalytical determination of estriol hormone using a boron-doped diamond electrode
    Santos, Keliana D.
    Braga, Otoniel C.
    Vieira, Iolanda C.
    Spinelli, Almir
    TALANTA, 2010, 80 (05) : 1999 - 2006
  • [26] Improved procedure for square-wave voltammetric sensing of fenhexamid residues on blueberries peel surface at the anodically pretreated boron-doped diamond electrode
    Brycht, Mariola
    Skrzypek, Slawomira
    Mirceski, Valentin
    ANALYTICA CHIMICA ACTA, 2023, 1249
  • [27] Square wave voltammetry on boron-doped diamond electrodes for analytical determinations
    Codognoto, L
    Machado, SAS
    Avaca, LA
    DIAMOND AND RELATED MATERIALS, 2002, 11 (09) : 1670 - 1675
  • [28] Square-wave voltammetric determination of bezafibrate in pharmaceutical formulations using a cathodically pretreated boron-doped diamond electrode
    Ardila, Jorge Armando
    Sartori, Elen Romao
    Rocha-Filho, Romeu C.
    Fatibello-Filho, Orlando
    TALANTA, 2013, 103 : 201 - 206
  • [29] Electrochemical determination of pterostilbene at a cathodically pretreated boron-doped diamond electrode using square-wave adsorptive anodic stripping voltammetry in cationic surfactant media
    Yigit, Aydin
    Yardim, Yavuz
    Zorer, Ozlem Selcuk
    Senturk, Zuhre
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 231 : 688 - 695
  • [30] Square-wave voltammetric determination of rosuvastatin calcium in pharmaceutical and biological fluid samples using a cathodically pretreated boron-doped diamond electrode
    Silva, Tiago A.
    Pereira, Gabriel F.
    Fatibello-Filho, Orlando
    Eguiluz, Katlin I. B.
    Salazar-Banda, Giancarlo R.
    DIAMOND AND RELATED MATERIALS, 2015, 58 : 103 - 109