Miniplate and K-Wire Fixation for Type Vb Jersey Finger: A Case Series of Nine Patients

被引:0
作者
Li, Bin [1 ]
Yang, Yong [1 ]
Li, Feng [1 ]
Huang, Xingjian [1 ]
Cao, Mengqi [1 ]
Yin, Yaobin [1 ]
机构
[1] Beijing Jishuitan Hosp, Dept Hand Surg, 31 Xinjiekou East St, Beijing, Peoples R China
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 2024年 / 49卷 / 08期
关键词
Jersey fi nger; K-wire fi xation; plate fi xation; PROFUNDUS TENDON; FLEXOR TENDONS; DISTAL PHALANX; AVULSION; INJURIES; RUPTURES;
D O I
10.1016/j.jhsa.2022.10.009
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose The aim of this study was to present the results of plate and K-wire fixation for type Vb jersey finger. Methods We used a miniplate system combined with a K-wire to treat nine cases of acute type Vb jersey finger injury. The fracture healing time, functional outcomes, and complications were assessed. Results The follow-up time ranged from 13 to 44 months. All fractures healed within 7 weeks. The mean active range of motion was 70.6 degrees degrees (60 degrees degrees to 80 degrees) degrees ) for the distal interphalangeal joint and 105 degrees degrees (100 degrees degrees to 110 degrees) degrees ) for the proximal interphalangeal joint. All affected fi ngers were able to move actively with no pain, and there was no nail deformity. Two patients with the longest radiographic follow-up showed a congruent joint surface with no degenerative change at 44 months. Conclusions Miniplate and K-wire fi xation offers adequate fi xation strength for the early initiation of active exercises so that a good functional result can be achieved.
引用
收藏
页码:799e1 / 799e6
页数:6
相关论文
共 18 条