Agreement between the Heidelberg Retina Tomograph (HRT) Stereometric Parameters Estimated Using HRT-I and HRT-II

被引:3
作者
Balasubramanian, Madhusudhanan [1 ]
Bowd, Christopher [1 ]
Weinreb, Robert N. [1 ]
Zangwill, Linda M. [1 ]
机构
[1] Univ Calif San Diego, Dept Ophthalmol, Hamilton Glaucoma Ctr, La Jolla, CA 92093 USA
关键词
glaucoma; optic disk topography; stereometric parameters; HRT-I; HRT-II; agreement; parabolic error correction; SCANNING LASER OPHTHALMOSCOPE; OPEN-ANGLE GLAUCOMA; RIM AREA; OCULAR HYPERTENSION; VARIABILITY; REPEATABILITY;
D O I
10.1097/OPX.0b013e3181fc3467
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To assess agreement between Heidelberg Retina Tomograph (HRT)-I and HRT-II stereometric parameters and to determine whether parabolic error correction (PEC) to the topographies improves agreement. Methods. University of California San Diego Diagnostic Innovations in Glaucoma Study participants with two HRT-II examinations (n = 380) or one HRT-I and one HRT-II examinations (n = 344) acquired on the same day were included. From the group of 380 eyes, 200 eyes were randomly selected to estimate the repeatability coefficients of HRT-II rim area and volume, cup area and volume, and mean retinal nerve fiber layer (RNFL) thickness parameters (HRT-II control group), and the remaining 180 eyes were used to assess agreement between two HRT-II examinations (HRT-II study group). Agreement between stereometric parameters of HRT-I and HRT-II examinations (HRT-I vs. HRT-II study group) were assessed with (1) no PEC, (2) HRT PEC, and (3) a modified PEC. Bland-Altman plots were used to assess agreement using estimates of bias and clinical limits of agreement (CLA) based on repeatability coefficients. Results. In the HRT-II study group, agreement between stereometric parameters was good, with no statistically significant biases. For all parameters, differences were within the CLA in 94% of participants. In the HRT-I vs. HRT-II study group, there was a small statistically significant bias between the stereometric parameters, but all differences were within CLA for >= 95% of participants. In both study groups, PEC did not improve agreement. Conclusions. Agreement between HRT-I and HRT-II stereometric parameters was good, and PEC did not improve agreement. These results suggest that HRT-I and HRT-II examinations can be used interchangeably to detect changes in stereometric parameters over time. (Optom Vis Sci 2011; 88: 140-149)
引用
收藏
页码:140 / 149
页数:10
相关论文
共 23 条
  • [1] Altman DG, 2002, CLIN CHEM, V48, P801
  • [2] Agreement between Heidelberg Retina Tomograph-I and -II in detecting glaucomatous changes using topographic change analysis
    Balasubramanian, M.
    Bowd, C.
    Weinreb, R. N.
    Zangwill, L. M.
    [J]. EYE, 2011, 25 (01) : 31 - 42
  • [3] Measurement error
    Bland, JM
    Altman, DG
    [J]. BRITISH MEDICAL JOURNAL, 1996, 312 (7047) : 1654 - 1654
  • [4] Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
  • [5] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [6] EKSBORG S, 1981, CLIN CHEM, V27, P1311
  • [7] Inter- and intraobserver variation in the analysis of optic disc images: comparison of the Heidelberg retina tomograph and computer assisted planimetry
    Garway-Heath, DF
    Poinoosawmy, D
    Wollstein, G
    Viswanathan, A
    Kamal, D
    Fontana, L
    Hitchings, RA
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 1999, 83 (06) : 664 - 669
  • [8] *HEID ENG GMBH, 2005, HEID RET TOM OP MAN
  • [9] Method comparison in the clinical laboratory
    Jensen, Asger Lundorff
    Kjelgaard-Hansen, Mads
    [J]. VETERINARY CLINICAL PATHOLOGY, 2006, 35 (03) : 276 - 286
  • [10] A comparison of optic disc topographic parameters in patients with primary open angle glaucoma, normal tension glaucoma, and ocular hypertension
    Kiriyama, N
    Ando, A
    Fukui, C
    Nambu, H
    Nishikawa, M
    Terauchi, H
    Kuwahara, A
    Matsumura, M
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2003, 241 (07) : 541 - 545