A transcrestal sinus floor elevation strategy based on a haptic robot system: An in vitro study

被引:2
作者
Yu, Shimin [1 ,2 ]
Wang, Yulan [1 ,2 ]
Wang, Yunxiao [1 ,2 ]
Miron, Richard J. [3 ]
Yan, Qi [1 ,2 ,5 ]
Zhang, Yufeng [1 ,2 ,4 ,5 ]
机构
[1] Wuhan Univ, Sch & Hosp Stomatol, Minist Educ, State Key Lab Oral & Maxillofacial Reconstruct & R, Wuhan, Peoples R China
[2] Wuhan Univ, Med Res Inst, Sch Med, Wuhan, Peoples R China
[3] Univ Bern, Dept Periodontol, Bern, Switzerland
[4] Oral Biomat & Applicat Technol Engn Res Ctr Hubei, Wuhan, Peoples R China
[5] Wuhan Univ, Sch & Hosp Stomatol, Dept Oral Implantol, 237 Luoyu Rd, Wuhan 430079, Peoples R China
基金
中央高校基本科研业务费专项资金资助;
关键词
cone-beam computed tomography; force feedback; membrane perforation; robot-assisted surgery; transcrestal sinus floor elevation; MAXILLARY SINUS; SCHNEIDERIAN MEMBRANE; AUGMENTATION;
D O I
10.1111/cid.13384
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To reveal the force profiles recorded by haptic autonomous robotic force feedback during the transcrestal sinus floor elevation (TSFE) process, providing a reference for the surgery strategy during TSFE. Materials and methods: A total of 42 maxillary sinus models with different angles of the sinus floor (30 degrees, 40 degrees, 50 degrees, 60 degrees, 70 degrees, 80 degrees, and 90 degrees, compared to vertical plane) were 3D printed. Implant site preparation was performed using a robotic system, and the total force (Ft) and axial force along the drill (Fz) during the surgery were recorded by the haptic robotic arm. The actual initial breakthrough point (drill contacting sinus floor) and complete breakthrough point (drill penetrating the sinus floor) were defined visually (the actual IBP and the actual CBP). The theoretical initial breakthrough point (the theoretical IBP) and the theoretical complete breakthrough point (the theoretical CBP) defined by the robot-guided system and the CBCT were determined by realtime force feedback and imaging distance measurement, respectively. The distance from the bottom of the resin model to the actual IBP and the actual CBP was defined as Di and Dt, respectively. Results: The difference in Fz began to increase significantly at 70 degrees, while the difference in Ft became significant at 60 degrees. When the angle was greater than 70 degrees, there was no significant difference in the discrepancy between the actual and theoretical perforation points. Compared to judging the breakthrough point by CBCT, real-time force feedback TSFE under robotic surgery achieved more accurate initial breakthrough point detection. Conclusions: The smaller the angle, the larger the breakthrough force for the drill. The real-time force feedback of haptic robotic system during TSFE could provide reliable reference for dentists. More clinical studies are needed to further validate the application of robotic surgery assisted TSFE.
引用
收藏
页码:1270 / 1278
页数:9
相关论文
共 28 条
  • [1] Does intraoperative perforation of Schneiderian membrane during sinus lift surgery causes an increased the risk of implants failure?: A systematic review and meta regression analysis
    Al-Moraissi, Essam
    Elsharkawy, Ahmed
    Abotaleb, Bassam
    Alkebsi, Khaled
    Al-Motwakel, Hamza
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2018, 20 (05) : 882 - 889
  • [2] Clinical Performance of Dental Implants Following Sinus Floor Augmentation: A Systematic Review and Meta-Analysis of Clinical Trials with at Least 3 Years of Follow-up
    Antonoglou, Georgios N.
    Stavropoulos, Andreas
    Samara, Maria D.
    Ioannidis, Alexis
    Benic, Goran I.
    Papageorgiou, Spyridon N.
    Sandor, George K.
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (03) : E45 - E65
  • [3] Endoscopic evaluation of the bone-added osteotome sinus floor elevation procedure
    Berengo, M
    Sivolella, S
    Majzoub, Z
    Cordioli, G
    [J]. INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2004, 33 (02) : 189 - 194
  • [4] Accuracy of haptic robotic guidance of dental implant surgery for completely edentulous arches
    Bolding, Scotty L.
    Reebye, Uday N.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (04) : 639 - 647
  • [5] Comparison the accuracy of a novel implant robot surgery and dynamic navigation system in dental implant surgery: an in vitro pilot study
    Chen, Jianping
    Bai, Xiaolei
    Ding, Yude
    Shen, Liheng
    Sun, Xin
    Cao, Ruijue
    Yang, Fan
    Wang, Linhong
    [J]. BMC ORAL HEALTH, 2023, 23 (01)
  • [6] Deep learning-based fully automatic segmentation of the maxillary sinus on cone-beam computed tomographic images
    Choi, Hanseung
    Jeon, Kug Jin
    Kim, Young Hyun
    Ha, Eun-Gyu
    Lee, Chena
    Han, Sang-Sun
    [J]. SCIENTIFIC REPORTS, 2022, 12 (01)
  • [7] Cosci F, 2000, Implant Dent, V9, P363, DOI 10.1097/00008505-200009040-00014
  • [8] A new technique for the transcrestal sinus floor elevation and alveolar ridge augmentation with press-fit bone cylinders: A technical note
    Draenert, G. F.
    Eisenmenger, W.
    [J]. JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2007, 35 (4-5) : 201 - 206
  • [9] Effectiveness and complications of transcrestal sinus floor elevation using the cushioned grind-out technique: A retrospective cohort study with up to 7 years of follow-up
    Gao, Jiayu
    Yin, Wumeng
    Liu, Yeyu
    Zhao, Xiangqi
    Qu, Yili
    Man, Yi
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 2023, 50 (09) : 1202 - 1216
  • [10] The Incidence of Maxillary Sinus Membrane Perforation During Endoscopically Assessed Crestal Sinus Floor Elevation: A Pilot Study
    Garbacea, Antoanela
    Lozada, Jaime L.
    Church, Christopher A.
    Al-Ardah, Aladdin J.
    Seiberling, Kristin A.
    Naylor, W. Patrick
    Chen, Jung-Wei
    [J]. JOURNAL OF ORAL IMPLANTOLOGY, 2012, 38 (04) : 345 - 360