Biomechanical effects of endplate sagittal coverage change on cervical disc replacement: a finite element analysis

被引:0
作者
Chen, Lihua [1 ]
Wang, Haiyan [2 ]
Xu, Guangming [3 ,4 ]
Liu, Hao [5 ]
机构
[1] Guangzhou Univ Chinese Med, Shenzhen Baoan Tradit Chinese Med Hosp, Dept Rehabil, Shenzhen, Peoples R China
[2] Shenzhen Baoan Chinese Med Hosp, Dept Famous Tradit Chinese Med Hall, Shenzhen, Guangdong, Peoples R China
[3] Shenzhen PingleOrthoped Hosp, Dept Orthopaed, Shenzhen, Guangdong, Peoples R China
[4] Shenzhen Pingshan Tradit Chinese Med Hosp, Shenzhen, Guangdong, Peoples R China
[5] Guangxi Univ Chinese Med, Ruikang Hosp, Dept Chinese Med Master Hall, Nanning, Guangxi, Peoples R China
来源
FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY | 2024年 / 12卷
关键词
cervical vertebra; cervical disc replacement; endplate; finite element; heterotopic ossification; HETEROTOPIC OSSIFICATION; CLINICAL-TRIAL; PROSTHESIS; DISKECTOMY; FUSION; ARTHROPLASTY; RATES; SPINE;
D O I
10.3389/fbioe.2024.1371548
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Background In recent years, the number of artificial cervical disc replacements has increased, and paravertebral ectopic ossification is a common complication. Although the exact mechanism is not clear, some studies suggest that it is related to the concentration of tissue stress caused by incomplete coverage of the trailing edge of the endplate. Therefore, this study performed a quantitative analysis to compare the biomechanical effects of different sagittal distances at the posterior edge of the endplate of the upper and lower prosthesis on the cervical spine and to explore the mechanical response of incomplete coverage of the posterior edge of the endplate on the paravertebral tissues.Methods A C2-C7 nonlinear finite element model of the cervical spine was established and validated. Based on the cervical spine model, cervical disc replacement surgery models were constructed with different distances of sagittal distance at the posterior edge of the upper prosthetic endplate (0, 1, 2, 3 mm, respectively) and sagittal distance at the posterior edge of the lower prosthetic endplate (1, 2, 3 mm, respectively). Each model was subjected to the same 1Nm torque and 73.6N driven compressive load. Range of motion (ROM), intervertebral disc pressure (IDP), facet joint force (FJF), and endplate stress were measured at the cervical surgical and other segments.Results Compared to the intact cervical spine model, the sagittal distance of the posterior edge of the prosthesis endplate at different distances increased the stress on the intervertebral disc and the capsular joint in the adjacent vertebral body segments to different degrees, especially in extension. In different directions of motion, the posterior margin sagittal distance of the posterior edge of the endplate of the lower prosthesis has a greater mechanical influence on the cervical spine compared to the posterior margin sagittal distance of the posterior edge of the endplate of the upper prosthesis. Compared with the intact model, the biomechanical parameters (ROM, FJF, endplate stress) of the C5-C6 segment increased the most when the sagittal distance of the posterior edge of the endplate of the upper prosthesis was 3 mm. Compared with the intact model, the maximum intervertebral disc stress of C4-C5 and C6-C7 was 0.57 MPa and 0.53 MPa, respectively, when the sagittal distance of the posterior edge of the upper prosthetic endplate was 3 mm.Conclusion After the sagittal distance of the posterior edge of the prosthetic endplate was completely covered, the mechanical influence of the entire cervical spine was low. The sagittal distance at the posterior edge of the endplate of different sizes changed the motion pattern and load distribution of the implanted segment to some extent. When the sagittal distance between the prosthesis and the upper endplate was greater than or equal to 3 mm, the mechanical indices of the implanted segment increased significantly, increasing the risk of local tissue injury, especially during extension motion. Compared to the sagittal distance at the posterior edge of the endplate of the lower prosthesis, increasing the sagittal distance at the posterior edge of the endplate of the upper prosthesis has a greater effect on the mechanics of the cervical spine.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Biomechanical Analysis of Two-level Cervical Disc Replacement With a Stand-alone U-shaped Disc Implant
    Li, Yang
    Fogel, Guy R.
    Liao, Zhenhua
    Tyagi, Rajnesh
    Zhang, Gaolong
    Liu, Weiqiang
    SPINE, 2017, 42 (20) : E1173 - E1181
  • [22] Biomechanical Analysis of Cervical Disc Replacement and Fusion Using Single Level, Two Level, and Hybrid Constructs
    Gandhi, Anup A.
    Kode, Swathi
    DeVries, Nicole A.
    Grosland, Nicole M.
    Smucker, Joseph D.
    Fredericks, Douglas C.
    SPINE, 2015, 40 (20) : 1578 - 1585
  • [23] Comparison of the safety of outpatient cervical disc replacement with inpatient cervical disc replacement A protocol for a meta-analysis
    Wang, Xiaofei
    Meng, Yang
    Liu, Hao
    Hong, Ying
    Wang, Beiyu
    MEDICINE, 2020, 99 (35)
  • [24] Effects of New Cage Profiles on the Improvement in Biomechanical Performance of Multilevel Anterior Cervical Corpectomy and Fusion: A Finite Element Analysis
    Liu, Ning
    Lu, Teng
    Wang, Yibin
    Sun, Zhongwei
    Li, Jialiang
    He, Xijing
    WORLD NEUROSURGERY, 2019, 129 : E87 - E96
  • [25] The appropriate hybrid surgical strategy in three-level cervical degenerative disc disease: a finite element analysis
    Xie, Y. M.
    Zheng, Y. C.
    Qiu, S. J.
    Gong, K. Q.
    Duan, Y.
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2019, 14 (01)
  • [26] Segment selection for fusion and artificial disc replacement in the hybrid surgical treatment of noncontiguous cervical spondylosis: a finite element analysis
    Sun, Xiangyao
    Huang, Jiang
    Zhang, Qingming
    Cao, Li
    Liu, Yuqi
    Song, Zelong
    Tang, Wei
    Sun, Siyuan
    Wang, Juyong
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12
  • [27] Biomechanical analysis of cervical range of motion and facet contact force after a novel artificial cervical disc replacement
    Zhao, Xin
    Yuan, Wei
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2019, 11 (05): : 3109 - 3115
  • [28] In vivo analysis of cervical kinematics after implantation of a minimally constrained cervical artificial disc replacement
    Koller, Heiko
    Meier, Oliver
    Zenner, Juliane
    Mayer, Michael
    Hitzl, Wolfgang
    EUROPEAN SPINE JOURNAL, 2013, 22 (04) : 747 - 758
  • [29] The Influence of Artificial Cervical Disc Prosthesis Height on the Cervical Biomechanics: A Finite Element Study
    Yuan, Wei
    Zhang, Haiping
    Zhou, Xiaoshu
    Wu, Weidong
    Zhu, Yue
    WORLD NEUROSURGERY, 2018, 113 : E490 - E498
  • [30] Biomechanical Analysis of Hip Replacement Stem Design: A Finite Element Analysis
    Azbari, Zahra Shamsipour
    Rad, Mohadese Rajaei
    Nahvinejad, Amirreza
    Gilakjani, Hasan Asadi
    Khorsandi, Mohammad
    2022 29TH NATIONAL AND 7TH INTERNATIONAL IRANIAN CONFERENCE ON BIOMEDICAL ENGINEERING, ICBME, 2022, : 305 - 309