Clinical Validation of Carotid-Femoral Pulse Wave Velocity Measurement Using a Multi-Beam Laser Vibrometer: The CARDIS Study

被引:0
|
作者
Badhwar, Smriti [1 ]
Marais, Louise [1 ]
Khettab, Hakim [2 ]
Poli, Federica [1 ]
Li, Yanlu [4 ,5 ]
Segers, Patrick [6 ]
Aasmul, Soren [7 ]
de Melis, Mirko [7 ]
Baets, Roel [4 ,5 ]
Greenwald, Steve [8 ]
Bruno, Rosa Maria [1 ,2 ,3 ]
Boutouyrie, Pierre [1 ,2 ,3 ]
机构
[1] Paris Cardiovasc Res Ctr PARCC, Inst Natl Sante & Rech Med INSERM, Paris, France
[2] Hop Europeen Georges Pompidou HEGP, AP HP, Paris, France
[3] Univ Paris Cite, Fac Med, Paris, France
[4] Ghent Univ imec, Photon Res Grp, Ghent, Belgium
[5] Univ Ghent, Ctr Nano & Biophoton, Ghent, Belgium
[6] Univ Ghent, IBiTech BioMMedA, Ghent, Belgium
[7] Medtron Bakken Res Ctr, Maastricht, Netherlands
[8] Queen Mary Univ London, Blizard Inst, Barts & London Sch Med & Dent, London, England
基金
欧盟地平线“2020”;
关键词
cardiovascular diseases; carotid-femoral pulse wave velocity; optics and photonics; risk factors; vascular stiffness; CARDIOVASCULAR RISK-FACTORS; ARTERIAL STIFFNESS; AORTIC STIFFNESS; DOPPLER VIBROMETER; REPRODUCIBILITY; MECHANISMS;
D O I
10.1161/HYPERTENSIONAHA.124.22729
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
BACKGROUND:Carotid-femoral pulse wave velocity (cfPWV) is the gold standard for noninvasive arterial stiffness assessment, an independent predictor of cardiovascular disease, and a potential parameter to guide therapy. However, cfPWV is not routinely measured in clinical practice due to the unavailability of a low-cost, operator-friendly, and independent device. The current study validated a novel laser Doppler vibrometry (LDV)-based measurement of cfPWV against the reference technique. METHODS:In 100 (50 men) hypertensive patients, cfPWV was measured using applanation tonometry (Sphygmocor) and the novel LDV device. This device has 2 handpieces with 6 laser beams each that simultaneously measure vibrations from the skin surface at carotid and femoral sites. Pulse wave velocity is calculated using ECG for the identification of cardiac cycles. An ECG-independent method was also devised. Cardiovascular risk score was calculated for patients between 40 and 75 years old using the WHO risk scoring chart. RESULTS:LDV-based cfPWV correlated significantly with tonometry (r=0.86, P<0.0001 ECG-dependent [cfPWVLDV_ECG] and r=0.80, P<0.001 ECG-independent [cfPWVLDV_w/oECG] methods). Bland-Altman analysis showed nonsignificant bias (0.65 m/s) and acceptable SD (1.27 m/s) between methods. Intraobserver coefficient of variance for LDV was 4.7% (95% CI, 3.0%-5.5%), and interobserver coefficient of variance was 5.87%. CfPWV correlated significantly with CVD risk (r=0.64, P<0.001; r=0.41, P=0.003; and r=0.37, P=0.006 for tonometry, LDV-with, and LDV-without ECG, respectively). CONCLUSIONS:The study demonstrates clinical validity of the LDV device. The LDV provides a simple, noninvasive, operator-independent method to measure cfPWV for assessing arterial stiffness, comparable to the standard existing techniques.
引用
收藏
页码:1986 / 1995
页数:10
相关论文
共 50 条
  • [41] Determinants of Brachial-Ankle Pulse Wave Velocity and Carotid-Femoral Pulse Wave Velocity in Healthy Koreans
    Jang, Shin Yi
    Ju, Eun Young
    Huh, Eun Hee
    Kim, Jung Hyun
    Kim, Duk-Kyung
    JOURNAL OF KOREAN MEDICAL SCIENCE, 2014, 29 (06) : 798 - 804
  • [42] Development and Validation of a Path Length Calculation for Carotid-Femoral Pulse Wave Velocity Measurement A TASCFORCE, SUMMIT, and Caerphilly Collaborative Venture
    Weir-McCall, Jonathan R.
    Brown, Liam
    Summersgill, Jennifer
    Talarczyk, Piotr
    Bonnici-Mallia, Michael
    Chin, Sook C.
    Khan, Faisel
    Struthers, Allan D.
    Sullivan, Frank
    Colhoun, Helen M.
    Shore, Angela C.
    Aizawa, Kunihiko
    Groop, Leif
    Nilsson, Jan
    Cockcroft, John R.
    McEniery, Carmel M.
    Wilkinson, Ian B.
    Ben-Shlomo, Yoav
    Houston, J. Graeme
    HYPERTENSION, 2018, 71 (05) : 937 - +
  • [43] Validation of a cuff-based device for measuring carotid-femoral pulse wave velocity in children and adolescents
    Tommy Y. Cai
    Alice Meroni
    Hasthi Dissanayake
    Melinda Phang
    Alberto Avolio
    David S. Celermajer
    Mark Butlin
    Michael R. Skilton
    Ahmad Qasem
    Journal of Human Hypertension, 2020, 34 : 311 - 318
  • [44] Validation of a cuff-based device for measuring carotid-femoral pulse wave velocity in children and adolescents
    Cai, Tommy Y.
    Meroni, Alice
    Dissanayake, Hasthi
    Phang, Melinda
    Avolio, Alberto
    Celermajer, David S.
    Butlin, Mark
    Skilton, Michael R.
    Qasem, Ahmad
    JOURNAL OF HUMAN HYPERTENSION, 2020, 34 (04) : 311 - 318
  • [45] AUTOMATED BRACHIAL-ANKLE VERSUS CAROTID-FEMORAL PULSE WAVE VELOCITY: COMPARISON AND VALIDATION VERSUS CAROTID DAMAGE
    Kollias, A.
    Kyriakoulis, K.
    Gravvani, A.
    Anagnostopoulos, I.
    Stergiou, G. S.
    JOURNAL OF HYPERTENSION, 2019, 37 : E312 - E312
  • [46] Improving the accuracy and robustness of carotid-femoral pulse wave velocity measurement using a simplified tube-load model
    Lisheng Xu
    Shuran Zhou
    Lu Wang
    Yang Yao
    Liling Hao
    Lin Qi
    Yudong Yao
    Hongguang Han
    Ramakrishna Mukkamala
    Stephen E. Greenwald
    Scientific Reports, 12
  • [47] Carotid-femoral pulse wave velocity assessment using novel cuff-based techniques: comparison with tonometric measurement
    Butlin, Mark
    Qasem, Ahmad
    Battista, Francesca
    Bozec, Erwan
    McEniery, Carmel M.
    Millet-Amaury, Eugenie
    Pucci, Giacomo
    Wilkinson, Ian B.
    Schillaci, Giuseppe
    Boutouyrie, Pierre
    Avolio, Alberto P.
    JOURNAL OF HYPERTENSION, 2013, 31 (11) : 2237 - 2243
  • [48] Improving the accuracy and robustness of carotid-femoral pulse wave velocity measurement using a simplified tube-load model
    Xu, Lisheng
    Zhou, Shuran
    Wang, Lu
    Yao, Yang
    Hao, Liling
    Qi, Lin
    Yao, Yudong
    Han, Hongguang
    Mukkamala, Ramakrishna
    Greenwald, Stephen E.
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [49] Estimation of carotid-femoral pulse wave velocity from finger photoplethysmography signal
    Gentilin, Alessandro
    Tarperi, Cantor
    Cevese, Antonio
    Mattioli, Anna Vittoria
    Schena, Federico
    PHYSIOLOGICAL MEASUREMENT, 2022, 43 (07)
  • [50] Measurement of pulse wave velocity in children: comparison of volumetric and tonometric sensors, brachial-femoral and carotid-femoral pathways
    Keehn, Louise
    Milne, Laura
    McNeill, Karen
    Chowienczyk, Phil
    Sinha, Manish D.
    JOURNAL OF HYPERTENSION, 2014, 32 (07) : 1464 - 1469