共 103 条
The acute effects of motor cortex transcranial direct current stimulation on athletic performance in healthy adults: A systematic review and meta-analysis
被引:1
作者:
Winker, Matteo
[1
,2
,3
]
Hoffmann, Sven
[4
]
Laborde, Sylvain
[5
]
Javelle, Florian
[6
]
机构:
[1] Univ Cologne, Cologne, Germany
[2] TU Dortmund Univ, Inst Sport & Sport Sci Performance & Hlth Sports M, Dortmund, Germany
[3] Univ Hagen, Inst Psychol, Psychol Methods & Evaluat, Hagen, Germany
[4] German Sport Univ Cologne, Inst Cardiovasc Res & Sports Med, Dept Mol & Cellular Sports Med, Cologne, Germany
[5] German Sport Univ Cologne, Inst Psychol, Dept Performance Psychol, Cologne, Germany
[6] German Sport Univ Cologne, Inst Cardiovasc Res & Sports Med, Dept Mol & Cellular Sports Med, NeuroPsychoImmunol Res Unit, Sportpark Mungersdorf 6, D-50933 Cologne, Germany
关键词:
anodal stimulation;
athletic performance;
brain stimulation;
cathodal stimulation;
tDCS;
transcranical direct current stimulation;
CEREBRAL-CORTEX;
ANODAL-TDCS;
STRENGTH;
TASK;
EXCITABILITY;
TIME;
PERCEPTION;
ENDURANCE;
FAILURE;
STROKE;
D O I:
10.1111/ejn.16488
中图分类号:
Q189 [神经科学];
学科分类号:
071006 ;
摘要:
This systematic review and meta-analysis assesses independently the acute effects of anodal and cathodal motor cortex transcranial direct current stimulation (tDCS) on athletic performance in healthy adults. Besides, it evaluates the unique and conjoint effects of potential moderators (i.e., stimulation parameters, exercise type, subjects' training status and risk of bias). Online database search was performed from inception until March 18th 2024 (PROSPERO: CRD42023355461). Forty-three controlled trials were included in the systematic review, 40 in the anodal tDCS meta-analysis (68 effects), and 9 (11 effects) in the cathodal tDCS meta-analysis. Performance enhancement between pre- and post-stimulation was the main outcome measure considered. The anodal tDCS effects on physical performance were small to moderate (g = .29, 95%CI [.18, .40], PI = -.64 to 1.23, I2 = 64.0%). Exercise type, training status and use of commercial tDCS were significant moderators of the results. The cathodal tDCS effects were null (g = .04, 95%CI [-.05, .12], PI = -.14 to .23, I2 = 0%), with a small to moderate heterogeneity entirely due to sampling error, thus impairing further moderator analysis. These findings hold significant implications for the field of brain stimulation and physical performance, as they not only demonstrate a small to moderate effect of acute tDCS but also identify specific categories of individuals, devices and activities that are more susceptible to improvements. By addressing the multidimensional factors influencing the mechanisms of tDCS, we also provide suggestions for future research. Results indicate a small favouring effect of anodal tDCS on athletic performance with large heterogeneity. Exercise type, training status and use of commercial tDCS significantly moderate anodal tDCS effects. Cathodal tDCS shows null effects, with small to moderate heterogeneity entirely due to sampling error.
引用
收藏
页码:5086 / 5110
页数:25
相关论文