Developing a reference method for indirect measurement of pasture evapotranspiration at sub-meter spatial resolution

被引:0
|
作者
Alam, Muhammad Shahinur [1 ,3 ]
Lamb, David William [2 ,3 ]
Rahman, Muhammad Moshiur [4 ]
Randall, Marcus [5 ]
机构
[1] Univ Tasmania, Tasmanian Inst Agr, Newnham, Tas 7248, Australia
[2] Food Agil Cooperat Res Ctr, Sydney, NSW 2000, Australia
[3] Univ New England, Precis Agr Res Grp, Armidale, NSW 2351, Australia
[4] Univ New England, Appl Agr Remote Sensing Ctr, Armidale, NSW 2351, Australia
[5] Bond Univ, Bond Business Sch, Gold Coast, Qld 4229, Australia
来源
SMART AGRICULTURAL TECHNOLOGY | 2024年 / 9卷
关键词
Evapotranspiration chamber; Pasture evapotranspiration; Direct Measurement; CLOSED-CHAMBER; PORTABLE CHAMBER; GAS-EXCHANGE; EVAPORATION; DOME;
D O I
10.1016/j.atech.2024.100567
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
To establish an indirect method for estimating and partitioning pasture evapotranspiration, it is vital to develop a direct reference method that aligns with the required temporal and spatial resolution. An evapotranspiration chamber offers an effective solution as it is easy to deploy and operates at an appropriate measurement scale. In this study, we prepared and tested a closed hemispherical chamber for on-site measurements of evaporation and/or transpiration. Advanced data monitoring and logging techniques were integrated to enhance the precision and reliability of direct in-field evapotranspiration measurements. During laboratory testing, vapor accumulation within the chamber was monitored to identify the best representative segment of the vapor accumulation curve. Results indicated that the instrument stabilizes its readings within 5 to 10 s post-deployment in laboratory settings. The subsequent 15 s produce stable readings that best represent actual vapor accumulation. The optimal fan speed, producing an air speed of 5.36 ms(-1) at the vicinity of the fan within the chamber, paired with a wire mesh above the vapor-producing surface, yielded the best results. The study established a calibration factor (C) of 1.02 based on the actual water loss and vapor accumulation readings from the sensors at this fan speed. Advanced data analytics were applied to derive the calibration factor and to calculate the values of evapotranspiration from the changing microclimate within the chamber. Direction towards complete automation and the limitations of the chamber in field measurement are provided. The chamber was also tested under field conditions, and the paper examines its practical application and necessary adjustments for field measurements.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Distributed Brillouin sensing with sub-meter spatial resolution: modeling and processing
    Beugnot, Jean-Charles
    Tur, Moshe
    Mafang, Stella Foaleng
    Thevenaz, Luc
    OPTICS EXPRESS, 2011, 19 (08): : 7381 - 7397
  • [2] Adjacency effect correction of optical satellite image with sub-meter spatial resolution
    Wang Tao
    Nan, Zhou
    Yi Wei-Ning
    Hong Jin
    Liu Xiao
    Li Xin
    Zhang Quan
    Liu Shi-Yu
    Li Zhao-Zhou
    Li Kai-Tao
    Cui Wen-Yu
    ACTA PHYSICA SINICA, 2021, 70 (13)
  • [3] DEVELOPMENT OF X-BAND AIRBORNE POLARIMETRIC AND INTERFEROMETRIC SAR WITH SUB-METER SPATIAL RESOLUTION
    Nadai, Akitsugu
    Uratsuka, S.
    Umehara, T.
    Matsuoka, T.
    Kobayashi, T.
    Satake, M.
    2009 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, VOLS 1-5, 2009, : 1164 - 1167
  • [4] AN API FOR SPACEBORNE SUB-METER RESOLUTION PRODUCTS FOR EARTH SCIENCE
    Neigh, Christopher S. R.
    Carroll, Mark L.
    Montesano, Paul M.
    Slayback, Daniel A.
    Wooten, Margaret R.
    Lyapustin, Alexei I.
    Shean, David E.
    Alexandrov, Oleg
    Macander, Matthew J.
    Tucker, Compton J.
    2019 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS 2019), 2019, : 5397 - 5400
  • [5] Distributed Fiber-Optic Dynamic-Strain Sensor With Sub-Meter Spatial Resolution and Single-Shot Measurement
    Wang, Yifan
    Liu, Qingwen
    Chen, Dian
    Li, He
    He, Zuyuan
    IEEE PHOTONICS JOURNAL, 2019, 11 (06):
  • [6] Distributed Brillouin sensing with sub-meter spatial resolution based on four-section pulse
    Yang, Zhisheng
    Hong, Xiaobin
    Wu, Jian
    Guo, Hongxiang
    Lin, Jingtong
    2013 OPTICAL FIBER COMMUNICATION CONFERENCE AND EXPOSITION AND THE NATIONAL FIBER OPTIC ENGINEERS CONFERENCE (OFC/NFOEC), 2013,
  • [7] 100 km BOTDA temperature sensor with sub-meter resolution
    Angulo-Vinuesa, Xabier
    Martin-Lopez, Sonia
    Corredera, Pedro
    Gonzalez-Herraez, Miguel
    22ND INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS, PTS 1-3, 2012, 8421
  • [8] Deriving High Spatial-Resolution Coastal Topography From Sub-meter Satellite Stereo Imagery
    Almeida, Luis Pedro
    Almar, Rafael
    Bergsma, Erwin W. J.
    Berthier, Etienne
    Baptista, Paulo
    Garel, Erwan
    Dada, Olusegun A.
    Alves, Bruna
    REMOTE SENSING, 2019, 11 (05)
  • [9] Differential chirped-pulse pair for sub-meter spatial resolution Brillouin distributed fiber sensing
    Le Floch, Sebastien
    Yang, Zhisheng
    Sauser, Florian
    Soto, Marcelo A.
    Thevenaz, Luc
    24TH INTERNATIONAL CONFERENCE ON OPTICAL FIBRE SENSORS, 2015, 9634
  • [10] Advanced Brillouin-based Distributed Optical Fibre Sensors With Sub-Meter Scale Spatial Resolution
    Thevenaz, Luc
    Foaleng, Stella M.
    Song, Kwang-Yong
    Chin, Sanghoon
    Primerov, Nikolay
    Beugnot, Jean-Charles
    Tur, Moshe
    2010 36TH EUROPEAN CONFERENCE AND EXHIBITION ON OPTICAL COMMUNICATION (ECOC), VOLS 1 AND 2, 2010,