Evaluation of a whole blood point-of-care coagulation analyzer in dogs

被引:0
|
作者
Conroy, Elizabeth M. [1 ,2 ]
Lyons, Bridget M. [2 ]
Koenig, Amie [1 ]
机构
[1] Univ Georgia, Dept Emergency & Crit Care, Athens, GA USA
[2] Univ Missouri, Dept Emergency & Crit Care, Columbia, MO USA
关键词
bleeding; canine; coagulation; hemostasis; point of care; trauma; PARTIAL THROMBOPLASTIN TIME; PROTHROMBIN TIME; PLATELET COUNT; ANEMIA; APTT;
D O I
10.1111/vec.13416
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective: To compare the accuracy of a point-of-care coagulation analyzer (POCCA) with a reference laboratory coagulation analyzer (LabCA) and to evaluate for confounding factors that could alter the performance of the POCCA. Design: Prospective, observational study. Setting: Two university veterinary teaching hospitals. Animals: Forty-three client-owned dogs undergoing coagulation testing between April 2020 and June 2021. Methods: Samples were obtained from dogs undergoing coagulation testing as part of a diagnostic workup. Prothrombin time (PT) and activated partial thromboplastin time (aPTT) were measured on the POCCA and on the LabCA. PCV, platelet count, total plasma protein, hyperbilirubinemia, hemolysis, lipemia, and autoagglutination were recorded. Results: Moderate correlation was seen for PT and strong correlation was seen for aPTT between the POCCA and the LabCA (PT: 0.59, P < 0.0001; aPTT: 0.71, P < 0.0001). The POCCA results were consistent with normal or hypocoagulable samples for 30 of 38 PT and 33 of 37 aPTT results, as identified by the LabCA. Samples with PCV of 30%-55% were moderately correlated (PT: 0.63, P = 0.0004; aPTT: 0.63, P = 0.0003), but those outside that range were more likely to register an error message on the POCCA or provide disparate results. When hemolysis was present, there was a weak correlation between the POCCA and the LabCA for PT (rho: 0.38 [95% confidence interval: 0.19-0.76], P = 0.18) and a strong correlation for aPTT (rho: 0.86 [95% confidence interval: 0.62-0.95], P < 0.0001). Samples with hyperbilirubinemia were strongly correlated for PT (0.97, P = 0.002) but not for aPTT. Lipemia and autoagglutination were not observed. Conclusion: There was an acceptable correlation in patients with PCV within the manufacturer's recommended reference range; however, measurements on samples with PCV outside the reference range were inconsistent with the LabCA. Caution should be used when using the POCCA in patients with coagulopathy and anemia or other potential confounders.
引用
收藏
页码:446 / 454
页数:9
相关论文
共 50 条
  • [1] Use of Citrated Whole Blood for Point-of-Care Viscoelastic Coagulation Testing in Dogs
    York, Whitney
    Smith, M. Ryan
    Liu, Chin-Chi
    FRONTIERS IN VETERINARY SCIENCE, 2022, 9
  • [2] Evaluation of a point-of-care coagulation analyzer (Abaxis VSPro) for identification of coagulopathies in dogs
    Dixon-Jimenez, Amy C.
    Brainard, Benjamin M.
    Cathcart, Curtis J.
    Koenig, Amie
    JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2013, 23 (04) : 402 - 407
  • [3] Evaluation of a point-of-care coagulation analyzer on patients undergoing cardiopulmonary bypass surgery
    Chavez, JJ
    Weatherall, JS
    Strevels, SM
    Liu, FQ
    Snider, CC
    Carroll, RC
    JOURNAL OF CLINICAL ANESTHESIA, 2004, 16 (01) : 7 - 10
  • [4] PREHOSPITAL COAGULATION MONITORING OF RESUSCITATION WITH POINT-OF-CARE DEVICES
    Schott, Ulf
    SHOCK, 2014, 41 : 26 - 29
  • [5] Evaluation of the Element point-of-care blood gas analyzer for use in horses
    Krueger, Clarisa R.
    Hackett, Eileen S.
    Hess, Ann M.
    Mama, Khursheed R.
    JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2020, 30 (03) : 279 - 285
  • [6] Microfluidic device and system for point-of-care blood coagulation measurement based on electrical impedance sensing
    Ramaswamy, Bharath
    Yeh, Yin-Ting Tim
    Zheng, Si-Yang
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 180 : 21 - 27
  • [7] Evaluation of a point-of-care anticoagulant rodenticide test for dogs
    Istvan, Stephanie A.
    Marks, Steven L.
    Murphy, Lisa A.
    Dorman, David C.
    JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2014, 24 (02) : 168 - 173
  • [8] Evaluation of the GEM®PCL Plus point-of-care device for neonatal coagulation assessment: An observational study on cord blood
    De Luca, Roberta
    Fontana, Pierre
    Poncet, Antoine
    De Moerloose, Philippe
    Pfister, Riccardo E.
    THROMBOSIS RESEARCH, 2014, 134 (02) : 474 - 478
  • [9] Clinical investigation of a point-of-care blood ammonia analyzer
    Goggs, Robert
    Serrano, Sergio
    Szladovits, Balazs
    Keir, Iain
    Ong, Ryan
    Hughes, Dez
    VETERINARY CLINICAL PATHOLOGY, 2008, 37 (02) : 198 - 206
  • [10] Evaluation of the i-STAT point-of-care capillary whole blood prothrombin time and international normalized ratio: Comparison to the Tcoag MDAII coagulation analyzer in the central laboratory
    Pena, J. A.
    Lewandrowski, K. B.
    Lewandrowski, E. L.
    Gregory, K.
    Baron, J. M.
    Van Cott, E. M.
    CLINICA CHIMICA ACTA, 2012, 413 (11-12) : 955 - 959