Internally-cooled atmospheric water harvesting enabling improved productivity

被引:0
|
作者
Feng, Yaohui [1 ]
Ge, Lurong [1 ]
Li, Qian [1 ]
Wang, Ruzhu [1 ]
Ge, Tianshu [1 ]
机构
[1] Shanghai Jiao Tong Univ, Inst Refrigerat & Cryogen, Engn Res Ctr Solar Power & Refrigerat, MOE, Shanghai 200240, Peoples R China
关键词
Water harvesting; Sorbent coating; Heat and mass transfer; Internal cooling; AIR;
D O I
10.1016/j.watres.2024.122293
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Sorption-based atmospheric water harvesting holds promise for alleviating water scarcity, but current prototypes have not shown significant increases in practical yields despite efforts in the enlarged engineering scale. This is due to weakened heat and mass transfer with a packed sorbent bed. In this work, the desiccant-coated adsorbers were employed to fabricate the water harvesting device that incorporates internal fluid for cooling and heating during sorption and desorption. Featured with an internal cooling effect, practical water productivity could be improved by 1.75-9.96 times with a low desorption temperature (45-62 degrees C). The continuous water harvesting system could produce 0.77-3.98 Lwater/kgsorbent/day with a thermal energy consumption of 7.7-30.4 MJ/kg in wide climates from 20 % to 80 % RH, providing a reference for device design in the engineering view. The demonstration revealed that using natural cooling in the sorption stage has great benefits in improving water harvesting performance, which can be integrated into the building sectors or a wider range of scenarios.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Experimental analysis of an internally-cooled liquid desiccant dehumidifier
    Zhang, Tao
    Liu, Xiaohua
    Jiang, Jingjing
    Chang, Xiaoming
    Jiang, Yi
    BUILDING AND ENVIRONMENT, 2013, 63 : 1 - 10
  • [2] Modeling and experimental analysis of an internally-cooled vapor chamber
    Wu, Guodong
    Luo, Yuhao
    Bai, Pengfei
    Wang, Huawei
    Cai, Ruipeng
    Tang, Yifan
    Chen, Xingliang
    Zhou, Guofu
    ENERGY CONVERSION AND MANAGEMENT, 2021, 235
  • [3] CONSTRUCTING, FABRICATING, AND FORMING INTERNALLY-COOLED CABLED SUPERCONDUCTORS
    OLMSTEAD, MM
    HOENIG, MO
    IEEE TRANSACTIONS ON MAGNETICS, 1981, 17 (01) : 922 - 924
  • [4] THERMAL ANALYSIS OF AN INTERNALLY-COOLED METAL-CUTTING TOOL
    JEFFRIES, NP
    ZERKLE, RD
    INTERNATIONAL JOURNAL OF MACHINE TOOL DESIGN AND RESEARCH, 1970, 10 (03): : 381 - &
  • [5] Performance numerical analysis on an internally-cooled liquid desiccant dehumidifier
    Chan, X. M.
    Liu, X. H.
    Jiang, Y.
    BUILDING SIMULATION 2007, VOLS 1-3, PROCEEDINGS, 2007, : 607 - 613
  • [6] Wetting behavior of a liquid film on an internally-cooled desiccant contactor
    Giannetti, Niccolo
    Yamaguchi, Seiichi
    Saito, Kiyoshi
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2016, 101 : 958 - 969
  • [7] Study on an internally-cooled liquid desiccant dehumidifier with CFD model
    Luo, Yimo
    Chen, Yi
    Yang, Hongxing
    Wang, Yuanhao
    APPLIED ENERGY, 2017, 194 : 399 - 409
  • [8] Experimental performance comparison of adiabatic and internally-cooled membrane dehumidifiers
    Annadurai, Gurubalan
    Tiwari, Shaligram
    Maiya, M. P.
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2018, 13 (03) : 240 - 249
  • [9] Experimental analysis of a novel internally-cooled dehumidifier with self-cooled liquid desiccant
    Lun, Wei
    Li, Kuining
    Liu, Bin
    Zhang, Hongji
    Yang, Yuxiao
    Yang, Cheng
    BUILDING AND ENVIRONMENT, 2018, 141 : 117 - 126
  • [10] Regression Models for Performance Prediction of Internally-Cooled Liquid Desiccant Dehumidifiers
    Pakari, Ali
    Ghani, Saud
    ENERGIES, 2022, 15 (05)