Operation Scheme analysis of a multipurpose small modular reactor under cogeneration condition based on a once-through steam generator dynamic model

被引:3
作者
Bai, Xi [1 ]
Wei, Yizhen [1 ]
Zhang, Ru [1 ]
Ma, Yongjian [1 ]
Sun, Peiwei [1 ]
Wei, Xinyu [1 ]
机构
[1] Xi An Jiao Tong Univ, 28 Xianning West Rd, Xian 710049, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Small modular reactor cogeneration; Once-through steam generator; Operation schemes; Control strategies; Cogeneration application; HYBRID ENERGY SYSTEM; HEAT-TRANSFER; ELECTRICITY; SIMULATION;
D O I
10.1016/j.applthermaleng.2024.124264
中图分类号
O414.1 [热力学];
学科分类号
摘要
Highly flexible load requirements and cogeneration economy need to challenge the operation of a multipurpose small modular reactor cogeneration plant with once-through steam generators. Therefore, the present study develops a once-through steam generator dynamic model to analyze the multipurpose small modular reactor operation scheme under cogeneration conditions at different power levels. The once-through steam generator dynamic model is derived based on conversation equations using the moving boundary method. It is verified with RELAP5 results and open literature and the maximum relative error is 3.21 %. Three operation schemes are proposed for multipurpose small modular reactor cogeneration operation: Scheme 1 with constant steam pressure and average coolant temperature, Scheme 2 with constant steam temperature and pressure, and Scheme 3 with constant steam temperature and pure sliding steam pressure. Steady-state and dynamic characteristics with three operation schemes are simulated and investigated at three power levels: 100 %, 70 % and 30 %. The steady-state results show that Scheme 1 is more favorable for the primary loop, while Scheme 2 is beneficial to the secondary loop, and Scheme 3 can improve the thermal efficiency at low power level. The transient findings indicate that disturbances from the reactor side have a significant impact on the once-through steam generator and the minimum settling time is 3.3 s. Consequently, steam temperature control of once-through steam generator is achieved by regulating the control rods for Schemes 2 and 3, while steam pressure is suggested to be controlled by the feedwater valve for Scheme 1. For cogeneration conditions at 70 % power level, Scheme 2 can achieve the highest steam flow of turbine, the highest steam flow of steam extraction and the smallest steam specific volume, which are 87.88 kg<middle dot>s(-1), 28.96 kg<middle dot>s(-1), and 0.0503 m(3)<middle dot>kg(-1), respectively. Scheme 2 is recommended for high power levels under cogeneration operation. In contrast, Scheme 1 is more suitable for the condensing unit operation for low power levels.
引用
收藏
页数:25
相关论文
共 40 条
  • [1] Performance analysis of a supercritical water-cooled nuclear reactor integrated with a combined cycle, a Cu-Cl thermochemical cycle and a hydrogen compression system
    Al-Zareer, Maan
    Dincer, Ibrahim
    Rosen, Marc A.
    [J]. APPLIED ENERGY, 2017, 195 : 646 - 658
  • [2] [Anonymous], 2017, IAEA NUCL ENERGY SER
  • [3] CORRELATION FOR BOILING HEAT TRANSFER TO SATURATED FLUIDS IN CONVECTIVE FLOW
    CHEN, JC
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY PROCESS DESIGN AND DEVELOPMENT, 1966, 5 (03): : 322 - &
  • [4] Nuclear hydrogen projects to support clean energy transition: Updates on international initiatives and IAEA activities
    Constantin, Alina
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2024, 54 : 768 - 779
  • [5] System-level modeling, analysis and coordinated control design for the pressurized water reactor nuclear power system
    Cui, Chengcheng
    Zhang, Junli
    Shen, Jiong
    [J]. ENERGY, 2023, 283
  • [6] Analysis of post-LOCA long-term core safety characteristics for the Small Modular Reactor ACP100
    Deng, Jian
    Dang, Gaojian
    Ding, Shuhua
    Qiu, Zhifang
    [J]. ANNALS OF NUCLEAR ENERGY, 2020, 142
  • [7] Dynamical modeling and coordinated control design of a multimodular nuclear power-hydrogen cogeneration plant
    Dong, Zhe
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2022, 272
  • [8] Flexible control of nuclear cogeneration plants for balancing intermittent renewables
    Dong, Zhe
    Li, Bowen
    Li, Junyi
    Guo, Zhiwu
    Huang, Xiaojin
    Zhang, Yajun
    Zhang, Zuoyi
    [J]. ENERGY, 2021, 221
  • [9] sCO2 power cycle/reverse osmosis distillation system for water-electricity cogeneration in nuclear powered ships and submarines
    Gumus, Emrah
    [J]. DESALINATION, 2024, 572
  • [10] NOMOGRAPH OF DITTUS-BOELTER EQUATION FOR HEATING AND COOLING LIQUIDS
    HEISS, JF
    COULL, J
    [J]. INDUSTRIAL AND ENGINEERING CHEMISTRY, 1951, 43 (05): : 1226 - 1229