Assessment of air quality in the Philadelphia, Pennsylvania subway

被引:1
|
作者
Karim, Anjum Shahina [1 ]
Malone, Maeve [1 ]
Bruno, Alex [1 ]
Eggler, Aimee L. [2 ]
Posner, Michael A. [3 ]
Shakya, Kabindra M. [1 ]
机构
[1] Villanova Univ, Dept Geog & Environm, Villanova, PA 19085 USA
[2] Villanova Univ, Dept Chem, Villanova, PA USA
[3] Villanova Univ, Dept Math & Stat, Villanova, PA USA
关键词
Air Pollution; Exposure assessment; Indoor dust/house dust/dust; Inhalation Exposure; Particulate Matter; AIRBORNE PARTICULATE MATTER; BLACK CARBON; ULTRAFINE PARTICLES; EXPOSURE; POLLUTION; POLLUTANTS; PM2.5; DUST; CITY; MORTALITY;
D O I
10.1038/s41370-024-00711-9
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Background: Subways are popular and efficient modes of transportation in cities. However, people are exposed to high levels of particulate matter (PM) in subways. Subway air quality in the United States has been investigated in a few cities, but data is lacking on simultaneous measurement of several pollutants, especially ultrafine particles (UFP) and black carbon (BC), in combination with different size fractions of PM. Objectives: The goals of this study are to assess air quality in a belowground subway and compare it with outdoor ambient levels, to examine temporal variability of PM in the subway, and to analyze the correlation between PM and BC. Methods: Particulate matter of varying sizes (PM1, PM2.5, PM10), UFP, and BC were measured using DustTrak, nanoparticle detector, and micro aethalometer, respectively. Measurements were made at the belowground subway platform and the aboveground street level at 15th Street subway station in Philadelphia during summer 2022. Results: Belowground mean PM1, PM2.5, and PM10 were 112.2 +/- 61.3 mu g/m(3), 120 +/- 65.5 mu g/m(3), and 182.1 +/- 132 mu g/m(3), respectively, which were 5.4, 5.7, and 7.6 times higher than the respective aboveground street levels. The UFP lung deposited surface area (LDSA) (59.4 +/- 36.2 mu m(2)/cm(3)) and BC (9.5 +/- 5.4 mu g/m(3)) belowground were 1.7 times and 10.7 times higher than the aboveground. The pollutant concentration varied from day-to-day on both the locations. A higher positive correlation was found between the belowground BC and PM2.5 (r = 0.51, p < 0.05) compared to the aboveground (r = 0.16, p < 0.05). Impact: This study showed high levels of particulate matter exposure at a belowground subway station in Philadelphia. Particulate matter levels were about 5 to 8 times higher at belowground subway station than the corresponding aboveground street level. Higher levels were also observed for UFP lung deposited surface area (LDSA), while black carbon levels showed the highest concentration at the belowground level by a factor of ten compared to the aboveground level. The study shows the need for air quality management at belowground subways to reduce particulate matter exposure for the commuters.
引用
收藏
页码:196 / 204
页数:9
相关论文
共 50 条
  • [31] The Aeroflex: A Bicycle for Mobile Air Quality Measurements
    Elen, Bart
    Peters, Jan
    Van Poppel, Martine
    Bleux, Nico
    Theunis, Jan
    Reggente, Matteo
    Standaert, Arnout
    SENSORS, 2013, 13 (01) : 221 - 240
  • [32] Subway platform air quality: Assessing the influences of tunnel ventilation, train piston effect and station design
    Moreno, T.
    Perez, N.
    Reche, C.
    Martins, V.
    de Miguel, E.
    Capdevila, M.
    Centelles, S.
    Minguillon, M. C.
    Amato, F.
    Alastuey, A.
    Querol, X.
    Gibbons, W.
    ATMOSPHERIC ENVIRONMENT, 2014, 92 : 461 - 468
  • [33] Monitoring of Ambient Air Quality Patterns and Assessment of Air Pollutants' Correlation and Effects on Ambient Air Quality of Lahore, Pakistan
    Khan, Waqas Ahmed
    Sharif, Faiza
    Khokhar, Muhammad Fahim
    Shahzad, Laila
    Ehsan, Nusrat
    Jahanzaib, Muhammad
    Ferrero, Enrico
    Kovac-Andric, Elvira
    ATMOSPHERE, 2023, 14 (08)
  • [34] Challenges and opportunities of low-cost sensors in capturing the impacts of construction activities on neighborhood air quality
    Jaafar, Weaam
    Xu, Junshi
    Farrar, Emily
    Jeong, Cheol-Heon
    Ganji, Arman
    Evans, Greg
    Hatzopoulou, Marianne
    BUILDING AND ENVIRONMENT, 2024, 254
  • [35] Comprehensive assessment of the indoor air quality in a chlorinated Olympic-size swimming pool
    Felgueiras, Fatima
    Mourao, Zenaida
    Morais, Catarina
    Santos, Hugo
    Gabriel, Marta Fonseca
    Fernandes, Eduardo de Oliveira
    ENVIRONMENT INTERNATIONAL, 2020, 136
  • [36] Assessment of Air Quality in two Different Urban Localities
    Al-Harbi, M.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH, 2014, 8 (01) : 15 - 26
  • [37] Assessment of school building air quality in a desert climate
    Al-Hubail, Jamal
    Al-Temeemi, Abdul-Salam
    BUILDING AND ENVIRONMENT, 2015, 94 : 569 - 579
  • [38] Indoor air quality control for improving passenger health in subway platforms using an outdoor air quality dependent ventilation system
    Kim, MinJeong
    Braatz, Richard D.
    Kim, Jeong Tai
    Yoo, ChangKyoo
    BUILDING AND ENVIRONMENT, 2015, 92 : 407 - 417
  • [39] Air Quality and Cardiovascular Mortality: Analysis of Recent Data
    Welker, Carson
    Huang, Jeffrey
    Ramakrishna, Harish
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2024, 38 (11) : 2801 - 2804
  • [40] Visibility, air quality and daily mortality in Shanghai, China
    Huang, Wei
    Tan, Jianguo
    Kan, Haidong
    Zhao, Ni
    Song, Weimin
    Song, Guixiang
    Chen, Guohai
    Jiang, Lili
    Jiang, Cheng
    Chen, Renjie
    Chen, Bingheng
    SCIENCE OF THE TOTAL ENVIRONMENT, 2009, 407 (10) : 3295 - 3300