Assessment of air quality in the Philadelphia, Pennsylvania subway

被引:1
|
作者
Karim, Anjum Shahina [1 ]
Malone, Maeve [1 ]
Bruno, Alex [1 ]
Eggler, Aimee L. [2 ]
Posner, Michael A. [3 ]
Shakya, Kabindra M. [1 ]
机构
[1] Villanova Univ, Dept Geog & Environm, Villanova, PA 19085 USA
[2] Villanova Univ, Dept Chem, Villanova, PA USA
[3] Villanova Univ, Dept Math & Stat, Villanova, PA USA
关键词
Air Pollution; Exposure assessment; Indoor dust/house dust/dust; Inhalation Exposure; Particulate Matter; AIRBORNE PARTICULATE MATTER; BLACK CARBON; ULTRAFINE PARTICLES; EXPOSURE; POLLUTION; POLLUTANTS; PM2.5; DUST; CITY; MORTALITY;
D O I
10.1038/s41370-024-00711-9
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Background: Subways are popular and efficient modes of transportation in cities. However, people are exposed to high levels of particulate matter (PM) in subways. Subway air quality in the United States has been investigated in a few cities, but data is lacking on simultaneous measurement of several pollutants, especially ultrafine particles (UFP) and black carbon (BC), in combination with different size fractions of PM. Objectives: The goals of this study are to assess air quality in a belowground subway and compare it with outdoor ambient levels, to examine temporal variability of PM in the subway, and to analyze the correlation between PM and BC. Methods: Particulate matter of varying sizes (PM1, PM2.5, PM10), UFP, and BC were measured using DustTrak, nanoparticle detector, and micro aethalometer, respectively. Measurements were made at the belowground subway platform and the aboveground street level at 15th Street subway station in Philadelphia during summer 2022. Results: Belowground mean PM1, PM2.5, and PM10 were 112.2 +/- 61.3 mu g/m(3), 120 +/- 65.5 mu g/m(3), and 182.1 +/- 132 mu g/m(3), respectively, which were 5.4, 5.7, and 7.6 times higher than the respective aboveground street levels. The UFP lung deposited surface area (LDSA) (59.4 +/- 36.2 mu m(2)/cm(3)) and BC (9.5 +/- 5.4 mu g/m(3)) belowground were 1.7 times and 10.7 times higher than the aboveground. The pollutant concentration varied from day-to-day on both the locations. A higher positive correlation was found between the belowground BC and PM2.5 (r = 0.51, p < 0.05) compared to the aboveground (r = 0.16, p < 0.05). Impact: This study showed high levels of particulate matter exposure at a belowground subway station in Philadelphia. Particulate matter levels were about 5 to 8 times higher at belowground subway station than the corresponding aboveground street level. Higher levels were also observed for UFP lung deposited surface area (LDSA), while black carbon levels showed the highest concentration at the belowground level by a factor of ten compared to the aboveground level. The study shows the need for air quality management at belowground subways to reduce particulate matter exposure for the commuters.
引用
收藏
页码:196 / 204
页数:9
相关论文
共 50 条
  • [11] Air Quality Assessment of Particulate Matter Near a Concrete Block Plant and Traffic in Bladensburg, Maryland
    Ezeugoh, Rosemary I.
    Puett, Robin
    Payne-Sturges, Devon
    Cruz-Cano, Raul
    Wilson, Sacoby M.
    ENVIRONMENTAL JUSTICE, 2020, 13 (03) : 75 - 85
  • [12] Evolution and comparative assessment of ambient air quality standards in China
    Zhao, Bingtao
    Su, Yaxin
    He, Shushen
    Zhong, Mei
    Cui, Guomin
    JOURNAL OF INTEGRATIVE ENVIRONMENTAL SCIENCES, 2016, 13 (2-4) : 85 - 102
  • [13] Installation of platform screen doors and their impact on indoor air quality: Seoul subway trains
    Son, Youn-Suk
    Jeon, Jae-Sik
    Lee, Hyung Joo
    Ryu, In-Cheol
    Kim, Jo-Chun
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2014, 64 (09) : 1054 - 1061
  • [14] PM10 AIR QUALITY ASSESSMENT IN AN INDUSTRIALIZED AREA OF THE MEDITERRANEAN BASIN. PROPOSAL FOR AN AIR QUALITY PLAN.
    Belen Vicente, Ana
    Sanfeliu, Teofilo
    Jordan, Manuel M.
    Pardo, Francisco
    FRESENIUS ENVIRONMENTAL BULLETIN, 2013, 22 (3A): : 870 - 878
  • [15] Sensor Validation for Monitoring Indoor Air Quality in a Subway Station
    Liu, Hongbin
    Kim, MinJeong
    Kang, OnYu
    Sankararao, B.
    Kim, JeongTai
    Kim, Jo-Chun
    Yoo, Chang Kyoo
    INDOOR AND BUILT ENVIRONMENT, 2012, 21 (01) : 205 - 221
  • [16] Factors controlling air quality in different European subway systems
    Martins, Vania
    Moreno, Teresa
    Mendes, Luis
    Eleftheriadis, Konstantinos
    Diapouli, Evangelia
    Alves, Celia A.
    Duarte, Marcio
    de Miguel, Eladio
    Capdevila, Marta
    Querol, Xavier
    Cruz Minguillon, Maria
    ENVIRONMENTAL RESEARCH, 2016, 146 : 35 - 46
  • [17] Air quality in Kuwait urban areas
    Matar, Hamad B.
    Al-Otaibi, Fahad A.
    Almutairi, Saad K.
    Alhubail, Jamal A.
    ENVIRONMENTAL QUALITY MANAGEMENT, 2024, 33 (03) : 555 - 566
  • [18] Does subway expansion improve air quality?
    Li, Shanjun
    Liu, Yanyan
    Purevjav, Avralt-Od
    Yang, Lin
    JOURNAL OF ENVIRONMENTAL ECONOMICS AND MANAGEMENT, 2019, 96 : 213 - 235
  • [19] Indoor air quality index for preoccupancy assessment
    Wagdi, Dalia
    Tarabieh, Khaled
    Abou Zeid, Mohamed Nagib
    AIR QUALITY ATMOSPHERE AND HEALTH, 2018, 11 (04) : 445 - 458
  • [20] Deterministic Decision Support System for the Assessment of Cities Based on Air Quality Indicators: Decision Support System Using DBA
    Garg, Rakesh
    Raheja, Supriya
    INTERNATIONAL JOURNAL OF DECISION SUPPORT SYSTEM TECHNOLOGY, 2022, 14 (01) : 1 - 2