共 37 条
Novel thermoplastic microvalves based on an elastomeric cyclic olefin copolymer
被引:1
作者:
Childers, Katie
[1
,2
]
Freed, Ian M.
[2
,3
]
Hupert, Mateusz L.
[4
]
Shaw, Benjamin
[2
,5
]
Larsen, Noah
[2
,6
]
Herring, Paul
[7
]
Norton, Jeanne H.
[7
]
Shiri, Farhad
[2
,3
]
Vun, Judy
[8
]
August, Keith J.
[8
]
Witek, Malgorzata A.
[2
,3
]
Soper, Steven A.
[1
,2
,3
,9
,10
]
机构:
[1] Univ Kansas, Bioengn Program, Lawrence, KS 66045 USA
[2] Univ Kansas, Ctr Biomodular Multiscale Syst Precis Med, Lawrence, KS 66045 USA
[3] Univ Kansas, Dept Chem, Lawrence, KS 66045 USA
[4] BioFluidica Inc, San Diego, CA 92121 USA
[5] Univ Kansas, Dept Chem Engn, Lawrence, KS 66045 USA
[6] Univ Kansas, Dept Engn Phys, Lawrence, KS 66045 USA
[7] Pittsburg State Univ, Dept Plast Engn Technol, Pittsburg, KS 66762 USA
[8] Childrens Mercy Hosp, Dept Pediat, Kansas City, MO 64108 USA
[9] Univ Kansas, Dept Mech Engn, Lawrence, KS 66045 USA
[10] Univ Kansas, Med Ctr, KU Canc Ctr, Kansas City, KS 66160 USA
关键词:
MINIMAL RESIDUAL DISEASE;
LARGE-SCALE INTEGRATION;
MICROFLUIDIC VALVES;
SURFACE CHARACTERIZATION;
PLASMA;
POLYETHYLENE;
PHOTODEGRADATION;
CELLS;
PUMPS;
MICROSTRUCTURES;
D O I:
10.1039/d4lc00501e
中图分类号:
Q5 [生物化学];
学科分类号:
071010 ;
081704 ;
摘要:
Microfluidic systems combine multiple processing steps and components to perform complex assays in an autonomous fashion. To enable the integration of several bio-analytical processing steps into a single system, valving is used as a component that directs fluids and controls introduction of sample and reagents. While elastomer polydimethylsiloxane has been the material of choice for valving, it does not scale well to accommodate disposable integrated systems where inexpensive and fast production is needed. As an alternative to polydimethylsiloxane, we introduce a membrane made of thermoplastic elastomeric cyclic olefin copolymer (eCOC), that displays unique attributes for the fabrication of reliable valving. The eCOC membrane can be extruded or injection molded to allow for high scale production of inexpensive valves. Normally hydrophobic, eCOC can be activated with UV/ozone to produce a stable hydrophilic monolayer. Valves are assembled following in situ UV/ozone activation of eCOC membrane and thermoplastic valve seat and bonded by lamination at room temperature. eCOC formed strong bonding with polycarbonate (PC) and polyethylene terephthalate glycol (PETG) able to hold high fluidic pressures of 75 kPa and 350 kPa, respectively. We characterized the eCOC valves with mechanical and pneumatic actuation and found the valves could be reproducibly actuated >50 times without failure. Finally, an integrated system with eCOC valves was employed to detect minimal residual disease (MRD) from a blood sample of a pediatric acute lymphoblastic leukemia (ALL) patient. The two module integrated system evaluated MRD by affinity-selecting CD19(+) cells and enumerating leukemia cells via immunophenotyping with ALL-specific markers.
引用
收藏
页码:4422 / 4439
页数:18
相关论文
共 37 条