Quantifying Distal Deltoid Disruption With Linear versus Curvilinear Plating of Proximal Humerus Fractures: A Cadaveric Study

被引:0
|
作者
Galal, Youssef [1 ]
Vohra, Arjun [1 ]
Saunders, Patrick [1 ]
Paul, Ben [1 ,2 ]
Hui, Clayton [1 ]
Yao, Stephen [1 ]
Lederman, Evan [1 ]
Mckee, Michael [1 ]
Shah, Anup [1 ]
机构
[1] Univ Arizona, Banner Univ Med Grp, Coll Med, Phoenix, AZ USA
[2] Creighton Univ Hlth Sci Phoenix, Phoenix, AZ USA
关键词
open reduction; internal fixation; plate fixation; proximal humerus; deltoid; OPEN REDUCTION; INTERNAL-FIXATION; SHOULDER ARTHROPLASTY; LOCKED PLATE; CLASSIFICATION; EPIDEMIOLOGY; PART;
D O I
10.1097/BOT.0000000000002871
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BACKGROUND: Plate fixation of proximal humeral fractures is usually associated with some degree of distal deltoid dissection. The purpose of this study was to quantify deltoid release with standard linear versus curvilinear plates used in the repair of proximal humeral fractures. METHODS: Seven nonpaired, fresh-frozen, clavicle-to-fingertip cadaveric shoulders met the inclusion criteria for this study. Four different proximal humerus implants were tested. One of these plates was curvilinear (89 mm), and the other 3 plates were linear (85, 98, 109 mm in length). Plates were compared based on the amount of deltoid insertion released for proper plate positioning. An analysis of variance with post hoc Tukey tests was conducted to compare mean deltoid disruption across the 3 shortest plate types from each manufacturer. A linear regression analysis was conducted to analyze the effect of plate length on mean deltoid release. RESULTS: The mean deltoid insertion length was 39.6 +/- 8.6 mm (n = 7). The curvilinear plate (89 mm) required the least amount of average deltoid release at 4.1 +/- 4.5 mm, or 12.1% of the deltoid insertion. Independent analysis of variance, including the 3 shortest plates from each manufacturer, found a significant effect of which plate was used on the amount of deltoid disruption that resulted (F(2, 18) = 18.0, P < 0.001, omega = 0.6). A linear regression including all 4 plates demonstrated a statistically significant direct relationship between the plate length and the mean deltoid released (y = 0.6x - 43.8, r(2) = 4). CONCLUSION: This study demonstrates that proximal humerus plate length has a direct relationship with the amount of deltoid released during plating. Although deltoid disruption is length dependent, plate shape (curvilinear vs. linear) could also be contributory. When comparing a curvilinear and a linear plate of similar lengths, the curvilinear plate resulted in less mean deltoid release.
引用
收藏
页码:566 / 570
页数:5
相关论文
共 37 条
  • [1] How to Use Fluoroscopic Imaging to Prevent Intraarticular Screw Perforation During Locked Plating of Proximal Humerus Fractures: A Cadaveric Study
    Lowe, Jason B.
    Monazzam, Shafagh
    Walton, Blaine
    Nelson, Elisha
    Wolinsky, Philip R.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2015, 29 (10) : e401 - e407
  • [2] Parallel Versus Orthogonal Plating for Distal Humerus Fractures
    Vennettilli, Marco
    Athwal, George S.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2012, 37A (04): : 819 - 820
  • [3] Treatment of Metaphyseal Defects in Plated Proximal Humerus Fractures with a New Augmentation Technique-A Biomechanical Cadaveric Study
    Zhelev, Daniel
    Hristov, Stoyan
    Zderic, Ivan
    Ivanov, Stoyan
    Visscher, Luke
    Baltov, Asen
    Ribagin, Simeon
    Stoffel, Karl
    Kralinger, Franz
    Winkler, Joerg
    Richards, R. Geoff
    Varga, Peter
    Gueorguiev, Boyko
    MEDICINA-LITHUANIA, 2023, 59 (09):
  • [4] Influence of age, gender, and radiographic features on the deltoid splitting approach for surgical osteosynthesis in displaced proximal humerus fractures: a comparison study
    Chen, Alvin Chao-Yu
    Chiu, Chih-Hao
    Hsu, Kuo-Yau
    Chan, Yi-Sheng
    BMC MUSCULOSKELETAL DISORDERS, 2017, 18
  • [5] Second generation locked plating of proximal humerus fractures-A prospective multicentre observational study
    Roederer, Goetz
    Erhardt, Johannes
    Kuster, Markus
    Vegt, Paul
    Bahrs, Christian
    Kinzl, Lothar
    Gebhard, Florian
    INTERNATIONAL ORTHOPAEDICS, 2011, 35 (03) : 425 - 432
  • [6] Intra-articular Distal Humerus Fractures: Parallel Versus Orthogonal Plating
    Haglin, Jack M.
    Kugelman, David N.
    Lott, Ariana
    Belayneh, Rebekah
    Konda, Sanjit R.
    Egol, Kenneth A.
    HSS JOURNAL, 2022, 18 (02) : 256 - 263
  • [7] Fatty degeneration of the deltoid muscle associated with displaced proximal humerus fractures A computed tomography study in 100 consecutive patients
    Panzica, M.
    Brandes, J.
    Schmiddem, U.
    Karch, A.
    Hawi, N.
    Krettek, C.
    Meller, R.
    TECHNOLOGY AND HEALTH CARE, 2017, 25 (05) : 959 - 967
  • [8] Displaced proximal humerus fractures treated with ORIF via the deltoid interfascicular approach vs the deltopectoral approach A prospective case-control study
    Liu, Bin
    Wang, Xinguang
    Wang, Chao
    Jiao, Zhenqing
    Chen, Wei
    MEDICINE, 2022, 101 (23) : E29075
  • [9] Biomechanical Analysis of Combined Medial Calcar and Lateral Locked Plating Versus Isolated Lateral Locked Plating of Proximal Humerus Fractures
    Kotler, Joshua A.
    Zuppke, Julia N.
    Abraham, Vivek M.
    Sanville, Jennifer A.
    Nabet, Austin C.
    Carofino, Bradley
    Gardner, Michael J.
    Smith, Christopher S.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2023, 37 (09) : E355 - E360
  • [10] Complex Proximal Humerus Fractures Treated With Locked Plating Utilizing an Extended Deltoid Split Approach With a Shoulder Strap Incision
    Gavaskar, Ashok S.
    Chowdary, Naveen
    Abraham, Samson
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2013, 27 (02) : 73 - 76