P-based referencing for correcting tissue artifacts in laser ablation-inductively coupled plasma-mass spectrometry imaging of cancer samples

被引:0
作者
Kronenberg, Katharina [1 ]
Hoffmann, Emily [2 ]
Hiddessen, Lena [1 ]
Maus, Bastian [2 ]
Gerwing, Mirjam [2 ]
Faber, Cornelius [2 ]
Sperling, Michael [1 ,3 ]
Wildgruber, Moritz [2 ,4 ]
Karst, Uwe [1 ]
机构
[1] Univ Munster, Inst Inorgan & Analyt Chem, Corrensstr 48, D-48149 Munster, Germany
[2] Univ Munster, Clin Radiol, D-48149 Munster, Germany
[3] European Virtual Inst Speciat Anal EVISA, D-48149 Munster, Germany
[4] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Radiol, D-81377 Munich, Germany
关键词
LA-ICP-MS; referencing; breast cancer; Gadofosveset; elemental bioimaging; MRI; LA-ICP-MS; CUTTING ARTIFACTS; CONTRAST AGENT;
D O I
10.1093/mtomcs/mfae034
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A referencing strategy based on the element P is presented to compensate for cryosectioning tissue artifacts in laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) data. The study examines how the gadolinium-based contrast agent Gadofosveset is distributed in murine cancer tissue, and illustrates how referenced images can compensate for tissue artifacts like folds, overlaps, and density variations. Compared to non-referenced images that provide information on the absolute distribution of the analyte, referenced images allow for the representation of the analyte distribution relative to the amount of material introduced into the instrument, which in this case is correlated to the P signal. Tissue artifacts were corrected in referenced images for both Gadofosveset and endogenous elements, such as Fe and Zn. Additionally, the referencing approach provides valuable information on the Gd uptake relative to the tissue density in necrotic compared to vital tumor areas, which is not obtained from in vivo magnetic resonance imaging (MRI) data. However, validation of in vivo MRI and ex vivo LA-ICP-MS methods was possible by establishing a mean ratio of necrotic to vital tumor areas in the T1-weighted image post Gadofosveset injection and the non-referenced LA-ICP-MS image of Gd. In summary, P-based correction of LA-ICP-MS imaging data allows for a more accurate spatial representation of certain elements, including endogenous and exogenous elements such as injected contrast agents. Graphical Abstract With the example of murine breast cancer tissue, a referencing strategy based on the element P is presented to correct for tissue artifacts in LA-ICP-MS imaging data.
引用
收藏
页数:8
相关论文
共 21 条
[1]   Cutting artefacts and cutting process in vitreous sections for cryo-electron microscopy [J].
Al-Amoudi, A ;
Studer, D ;
Dubochet, J .
JOURNAL OF STRUCTURAL BIOLOGY, 2005, 150 (01) :109-121
[2]  
ASLAKSON CJ, 1992, CANCER RES, V52, P1399
[3]   Factors affecting internal standard selection for quantitative elemental bio-imaging of soft tissues by LA-ICP-MS [J].
Austin, Christine ;
Fryer, Fred ;
Lear, Jessica ;
Bishop, David ;
Hare, Dominic ;
Rawling, Tristan ;
Kirkup, Les ;
McDonagh, Andrew ;
Doble, Philip .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2011, 26 (07) :1494-1501
[4]   Intravascular contrast agent T1 shortening:: fast T1 relaxometry in a carotid volunteer study [J].
Bock, Michael ;
Schulz, Jessica ;
Ueltzhoeffer, Stefan ;
Giesel, Frederik ;
Voth, Matthias ;
Essig, Marco .
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2008, 21 (05) :363-368
[5]   Laser ablation of soft tissue using a cryogenically cooled ablation cell [J].
Feldmann, J ;
Kindness, A ;
Ek, P .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (08) :813-818
[6]   An internal standardisation strategy for quantitative immunoassay tissue imaging using laser ablation inductively coupled plasma mass spectrometry [J].
Frick, Daniel A. ;
Giesen, Charlotte ;
Hemmerle, Teresa ;
Bodenmiller, Bernd ;
Guenther, Detlef .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2015, 30 (01) :254-259
[7]   Fundamental studies on the ablation behaviour of carbon in LA-ICP-MS with respect to the suitability as internal standard [J].
Frick, Daniel A. ;
Guenther, Detlef .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2012, 27 (08) :1294-1303
[8]   Weighted Linear Regression Improves Accuracy of Quantitative Elemental Bioimaging by Means of LA-ICP-MS [J].
Funke, Sabrina K., I ;
Sperling, Michael ;
Karst, Uwe .
ANALYTICAL CHEMISTRY, 2021, 93 (47) :15720-15727
[9]   Multiparametric MRI enables for differentiation of different degrees of malignancy in two murine models of breast cancer [J].
Gerwing, Mirjam ;
Hoffmann, Emily ;
Kronenberg, Katharina ;
Hansen, Uwe ;
Masthoff, Max ;
Helfen, Anne ;
Geyer, Christiane ;
Wachsmuth, Lydia ;
Hoeltke, Carsten ;
Maus, Bastian ;
Hoerr, Verena ;
Kraehling, Tobias ;
Hiddessen, Lena ;
Heindel, Walter ;
Karst, Uwe ;
Kimm, Melanie A. ;
Schinner, Regina ;
Eisenblaetter, Michel ;
Faber, Cornelius ;
Wildgruber, Moritz .
FRONTIERS IN ONCOLOGY, 2022, 12
[10]   Skip the beat: minimizing aliasing error in LA-ICP-MS measurements [J].
Hattendorf, Bodo ;
Hartfelder, Urs ;
Gunther, Detlef .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (03) :591-602