Transformation of waste thermocol into activated carbon for electrochemical detection of ammonia in an aqueous solution

被引:7
作者
Dubey, Aman [1 ]
Ahmed, Aamir [1 ]
Singh, Anoop [2 ,3 ]
Sundramoorthy, Ashok K. [4 ]
Arya, Sandeep [1 ]
机构
[1] Univ Jammu, Dept Phys, Jammu 180006, Jammu And Kashm, India
[2] SR Univ, Sch Sci & Humanities, Dept Phys, Warangal 506371, Telangana, India
[3] Saveetha Med Coll & Hosp, Saveetha Inst Med & Tech Sci, Ctr Global Hlth Res, Chennai 602105, Tamil Nadu, India
[4] Saveetha Dent Coll & Hosp, Saveetha Inst Med & Tech Sci, Ctr Nanobiosensors, Chennai 600077, Tamil Nadu, India
关键词
Waste thermocol sheets; Electrochemical sensors; Activated carbon; Potentiometric methods; Aquatic biodiversity; IONIC LIQUID; OXIDATION; TEMPERATURE; FABRICATION; SENSOR; OXIDE; ACID; FILM;
D O I
10.1016/j.diamond.2024.111596
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this study, waste thermocol sheets are used to synthesize activated carbon (AC) for the electrochemical detection of ammonia in an aqueous solution. The AC is characterized for its morphology, structure, and chemical composition via standard characterization techniques. AC shows promise for detecting ammonia in aqueous solutions due to its high adsorption capacity from large surface area and porosity. The electrochemical approach used to detect ammonia (NH3) in electrolyte solutions uses an AC electrode and is based mostly on the electro-oxidative conversion of ammonia species at the electrode's interface. AC electrodes fabricated on flexible conductive fabric (CF) are used for the electrochemical detection of ammonia at pH 6. The electrochemical sensing of ammonia in aqueous solutions involves its oxidation on the electrode's surface. Cyclic Voltammetry (CV) experiments were conducted over a pH range of 5 to 8, revealing optimal current responses at pH 6. Therefore, phosphate-buffered saline (PBS) at pH 6.0 was employed for all electrochemical analyses. Various concentrations of ammonia (10-100 ppm) were investigated within a voltage window of -0.3 V to 0.3 V, with current signals increasing proportionally with ammonia concentration. The limits of detection (LOD) and quantification (LOQ) were determined to be 28.55 ppm and 86.54 ppm, respectively. An incubation period of 3 min was observed for ammonia concentrations ranging from 0 to 40 ppm. Selectivity evaluations were conducted by assessing interference effects from ethanol (E), methanol (M), toluene (T), and uric acid (UA), revealing ammonia's distinctive peak, indicative of superior selectivity. Notably, the electrode exhibited remarkable stability, retaining approximately 95 % of the original signal over a 5-week duration. The reproducibility of the fabricated electrodes shows significant results. The repeatability was performed at room temperature in a buffer solution of pH 6 and at a 40-ppm concentration of ammonia and has shown almost similar results. Therefore, the fabricated AC sensing electrode has shown prominent stability, reproducibility, and repeatability. These sensing electrodes can be very beneficial for sensing applications.
引用
收藏
页数:11
相关论文
共 77 条
  • [51] Pushpanjali PA, 2020, ANAL BIOANAL ELECTRO, V12, P553
  • [52] Validated Electrochemical Method for Simultaneous Resolution of Tyrosine, Uric Acid, and Ascorbic Acid at Polymer Modified Nano-Composite Paste Electrode
    Raril, Chenthattil
    Manjunatha, Jamballi G.
    Ravishankar, Doddarasinakere K.
    Fattepur, Santosh
    Siddaraju, Gurumallappa
    Nanjundaswamy, Lingappa
    [J]. SURFACE ENGINEERING AND APPLIED ELECTROCHEMISTRY, 2020, 56 (04) : 415 - 426
  • [53] Low-cost voltammetric sensor based on an anionic surfactant modified carbon nanocomposite material for the rapid determination of curcumin in natural food supplement
    Raril, Chenthattil
    Manjunatha, Jamballi G.
    Tigari, Girish
    [J]. INSTRUMENTATION SCIENCE & TECHNOLOGY, 2020, 48 (05) : 561 - 582
  • [54] Reza M.S., 2020, Arab J. Basic and Appl. Sci., V27, P208, DOI [10.1080/25765299.2020.1766799, DOI 10.1080/25765299.2020.1766799]
  • [55] Activated Carbon as Superadsorbent and Sustainable Material for Diverse Applications
    Sharma, Gaurav
    Sharma, Shweta
    Kumar, Amit
    Lai, Chin Wei
    Naushad, Mu
    Shehnaz
    Iqbal, Jibran
    Stadler, Florian J.
    [J]. ADSORPTION SCIENCE & TECHNOLOGY, 2022, 2022
  • [56] Quantitative Colorimetric Detection of Dissolved Ammonia Using Polydiacetylene Sensors Enabled by Machine Learning Classifiers
    Siribunbandal, Papaorn
    Kim, Yong-Hoon
    Osotchan, Tanakorn
    Zhu, Zhigang
    Jaisutti, Rawat
    [J]. ACS OMEGA, 2022, 7 (22): : 18714 - 18721
  • [57] A comprehensive review on the synthesis, performance, modifications, and regeneration of activated carbon for the adsorptive removal of various water pollutants
    Srivastava, Ashish
    Gupta, Bramha
    Majumder, Abhradeep
    Gupta, Ashok Kumar
    Nimbhorkar, Shripad K.
    [J]. JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2021, 9 (05):
  • [58] Environmentally friendly method for determination of ammonia nitrogen in fertilisers and wastewaters based on flow injection-spectrophotometric detection using natural reagent from orchid flower
    Sukaram, Thanikan
    Sirisakwisut, Petcharat
    Sirirak, Jitnapa
    Nacapricha, Duangjai
    Chaneam, Sumonmarn
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2018, 98 (10) : 907 - 920
  • [59] Determination of Ammonium Ion Using a Reagentless Amperometric Biosensor Based on Immobilized Alanine Dehydrogenase
    Tan, Ling Ling
    Musa, Ahmad
    Lee, Yook Heng
    [J]. SENSORS, 2011, 11 (10) : 9344 - 9360
  • [60] Highly luminescent S-doped carbon dots for the selective detection of ammonia
    Travlou, Nikolina A.
    Secor, Jeff
    Bandosz, Teresa J.
    [J]. CARBON, 2017, 114 : 544 - 556