Color Stability of Various Orthodontic Clear Aligner Systems after Submersion in Different Staining Beverages

被引:1
|
作者
Olteanu, Nicolae Daniel [1 ]
Taraboanta, Ionut [1 ]
Panaite, Tinela [1 ]
Balcos, Carina [1 ]
Rosu, Sorana Nicoleta [1 ]
Vieriu, Raluca Maria [1 ]
Dinu, Stefania [2 ]
Zetu, Irina Nicoleta [1 ]
机构
[1] Univ Med & Pharm Iasi, Fac Dent Med Grigore T Popa, Dept Oral & Maxillofacial Surg, Str Univ 16, Iasi 700115, Romania
[2] Victor Babe Univ Med & Pharm Timisoara, Fac Dent Med, Dept Pedodont, 9 Revolutiei Bv, Timisoara 300041, Romania
关键词
clear aligner; polyethylene terephthalate glycol; thermoplastic elastomer; color stability; staining beverages; MECHANICAL-PROPERTIES; THERMOPLASTIC MATERIALS; WATER SORPTION; COMPOSITES; ROUGHNESS;
D O I
10.3390/ma17164009
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
This study aimed to compare the color changes in two different orthodontic clear aligner systems after submersion in various beverages for 14 days. The tested aligner systems were Taglus Premium made of polyethylene terephthalate glycol (the TAG group) and CA (R) Prodin+ made of a transparent copolyester and a thermoplastic elastomer (the PRO group). A total of 56 samples were firstly divided into two groups according to the tested system-TAG and PRO. Each group was subsequently divided in four subgroups according to immersion solution: A-artificial saliva, B-cola, C-coffee, D-red wine. Color measurements were performed on Days 1, 7 and 14 using a portable colorimeter and the CIE L*a*b* system. The obtained results showed significant color changes in both materials when exposed to coffee and red wine (p > 0.05). Samples in the PRO group showed a greater susceptibility to discoloration (higher Delta E values) when compared to the TAG group after submersion in cola (p = 0.025), coffee (p = 0.005) and red wine (p = 0.041) solutions. Statistical analysis revealed that all of the color parameters Delta L*, Delta a*, Delta b* and Delta E of both tested materials were affected by submersion in coffee solution for 14 days. In conclusion, the CA (R) Pro+ aligner system is more prone to staining compared to the Taglus material after submersion for 14 days in cola, coffee and red wine solutions. Submersion for 14 days in coffee solution alters all of the color parameters (Delta L, Delta a, Delta b and Delta E) of both tested aligner materials.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Color Stability of Orthodontic Ceramic Brackets and Adhesives in Potentially Staining Beverages-In Vitro Study
    Simunovic, Luka
    Blagec, Tadeja
    Vrankic, Andrea
    Mestrovic, Senka
    DENTISTRY JOURNAL, 2022, 10 (07)
  • [2] The Mechanical Properties of Orthodontic Aligners of Clear Aligner After Intraoral Use in Different Time Periods
    Siotou, Kalliopi
    Chountalas, Theofanis
    Katsavrias, Athanasios
    Siotos, Charalampos
    Mpalias, Konstantinos
    Semitekolos, Dionysios
    Charitidis, Constantinos
    Tsolakis, Apostolos I.
    ORTHODONTICS & CRANIOFACIAL RESEARCH, 2025, 28 (02) : 253 - 260
  • [3] Color Stability, Chemico-Physical and Optical Features of the Most Common PETG and PU Based Orthodontic Aligners for Clear Aligner Therapy
    Daniele, Valeria
    Macera, Ludovico
    Taglieri, Giuliana
    Spera, Loredana
    Marzo, Giuseppe
    Quinzi, Vincenzo
    POLYMERS, 2022, 14 (01)
  • [4] Effect of Staining Beverages on Color Stability of Composite: A Spectrophotometric Study
    Thakkar, Radhika
    Maini, Anuj P.
    Mogla, Sahil
    Qadri, Syed Shah Hussain
    Varma, Praveen K.
    Dubey, Alok
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2024, 16 : S389 - S392
  • [5] Color stability of hybrid ceramics exposed to beverages in different combinations
    Yerliyurt, Kaan
    Sarikaya, Isil
    BMC ORAL HEALTH, 2022, 22 (01)
  • [6] The color stability of artificial white spot lesions treated with resin infiltration after exposure to staining beverages
    Limvisitsakul, Apinya
    Komalsingsakul, Anisha
    Thamsrithip, Pongsakorn
    Thammasupapong, Yod
    Chaisomsukrudee, Supada
    Aramlerttrakul, Sorawit
    Senawongse, Pisol
    BMC ORAL HEALTH, 2024, 24 (01):
  • [7] Influence of composite type and light irradiance on color stability after immersion in different beverages
    Da Silva, Victoria Alberton
    Da Silva, Simone Alberton
    Pecho, Oscar E.
    Bacchi, Atais
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2018, 30 (05) : 390 - 396
  • [8] Addition of antibacterial agent effect on color stability of composites after immersion of different beverages
    Tuncdemir, Makbule T.
    Gulbahce, Nilgun
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2019, 31 (05) : 508 - 513
  • [9] Color stability and fluorescence of different orthodontic esthetic archwires
    da Silva, Dayanne Lopes
    Mattos, Claudia Trindade
    Almeida de Araujo, Marcus Vinicius
    de Oliveira Ruellas, Antonio Carlos
    ANGLE ORTHODONTIST, 2013, 83 (01) : 127 - 132
  • [10] Effect of different beverages on color stability and surface properties of composite resin materials
    Ozyurt, Esra
    Kurt, Aysegul
    COLOR RESEARCH AND APPLICATION, 2021, 46 (06) : 1382 - 1391