In vitro comparison of guide planes for removable partial dentures prepared with CAD-CAM-assisted templates, guiding rod templates, and freehand

被引:0
|
作者
Cheng, Ni [1 ,2 ,3 ]
Yu, Hai [1 ,2 ,3 ]
Shan, Wenxi [1 ,2 ,3 ]
Wu, Jiang [1 ,2 ,4 ]
机构
[1] Fourth Mil Med Univ, Sch Stomatol, State Key Lab Oral & Maxillofacial Reconstruct & R, Xian, Peoples R China
[2] Fourth Mil Med Univ, Sch Stomatol, Natl Clin Res Ctr Oral Dis, Xian, Peoples R China
[3] Fourth Mil Med Univ, Sch Stomatol, Shaanxi Key Lab Stomatol, Dept Prosthodont, Xian, Peoples R China
[4] Fourth Mil Med Univ, Sch Stomatol, Dept Dent Mat, Shaanxi Key Lab Stomatol, Xian, Peoples R China
关键词
Removable partial denture; Guide plane; CAD-CAM; Template; 3D trueness; RETENTION;
D O I
10.1016/j.jdent.2024.105322
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: This study aimed to evaluate the accuracy of computer-aided design and computer-aided manufacturing (CAD-CAM)-assisted templates (CCAT), guiding rod templates (GRT), and freehand (FH) preparation of guide planes. Methods: Forty-five identical maxillary resin casts were divided into three groups, in which the guide planes of the two abutment teeth were prepared using a CCAT (n=15), GRT (n=15), and FH (n=15). The CCAT and GRT were digitally designed on a digital cast of virtually prepared guide planes and fabricated using three-dimensional printing (3DP) technology. To assess the 3D trueness, the prepared guide planes were digitally scanned and compared to the virtually designed guide planes. The angle deviation was measured to assess the trueness of the direction of the guide plane preparation. Shapiro-Wilk and Levene's tests were used to check the normality and equivalence of the variance of the data. The data were compared by using the Kruskal-Wallis H test (alpha=0.05). Results: The CCAT group exhibited significantly better 3D trueness (78.5 +/- 19.8 mu m) than the GRT group (211.3 +/- 42.4 mu m, p<0.05) and the FH group (198.9 +/- 44.3 mu m, p<0.05). Additionally, the CCAT group (1.31 +/- 0.50 degrees) showed significantly smaller direction trueness compared to the GRT (4.65 +/- 0.72 degrees, p<0.05) and FH (5.64 +/- 0.70 degrees, p<0.05) groups. Conclusions: The novel CAD-CAM-assisted template significantly improved the quality of the guide planes compared with the GRT and FH procedures. This enhancement suggests that removable partial dentures can be predictably inserted immediately after guide plane preparation.
引用
收藏
页数:7
相关论文
共 2 条
  • [1] Preparing guiding planes for removable partial dentures: an in vitro comparison between assisted CAD-CAM template procedure and freehand preparation
    Bai, Hefei
    Ye, Hongqiang
    Chen, Hu
    Wang, Yong
    Zhou, Yongsheng
    Sun, Yuchun
    JOURNAL OF DENTISTRY, 2022, 123
  • [2] Comparison of four CAD-CAM guides for preparing guiding planes of removable partial dentures
    Bai, Hefei
    Ye, Hongqiang
    Chen, Hu
    Wang, Yong
    Zhou, Yongsheng
    Sun, Yuchun
    COMPUTERS IN BIOLOGY AND MEDICINE, 2022, 146