Enhanced Diagnostic Accuracy of Pulmonary Embolism: Integrating Low-Dose CT with V/Q SPECT
被引:0
|
作者:
Lasloom, Munassar Dakkam
论文数: 0引用数: 0
h-index: 0
机构:
King Khalid Hosp, Nucl Med Dept, POB 1120, Riyadh, Saudi ArabiaKing Khalid Hosp, Nucl Med Dept, POB 1120, Riyadh, Saudi Arabia
Lasloom, Munassar Dakkam
[1
]
Abuzaid, Mohamed
论文数: 0引用数: 0
h-index: 0
机构:
Univ Sharjah, Coll Hlth Sci, Med Diagnost Imaging Dept, Sharjah 27272, U Arab EmiratesKing Khalid Hosp, Nucl Med Dept, POB 1120, Riyadh, Saudi Arabia
Abuzaid, Mohamed
[2
]
机构:
[1] King Khalid Hosp, Nucl Med Dept, POB 1120, Riyadh, Saudi Arabia
[2] Univ Sharjah, Coll Hlth Sci, Med Diagnost Imaging Dept, Sharjah 27272, U Arab Emirates
Objective: This study aimed to retrospectively assess the benefits of combining low-dose computed tomography (LDCT) with ventilation/perfusion single-photon emission computed tomography (V/Q SPECT) for the diagnosis of pulmonary embolism (PE). Methods: A retrospective analysis was performed on 92 patients with suspected PE who underwent V/Q SPECT with ldCT (V/Q SPECT CT) between January 2020 and December 2022 at King Khalid Hospital Najran. Data were collected using the hospital's picture archiving and communication system. Scans were categorized on the basis of perfusion defects, matched or mismatched ventilation, and CT findings. The specificity of V/Q SPECT CT was compared with that of Q SPECT CT. Results: This study included 92 patients (54 females and 38 males; median age, 53 years). The results demonstrated that V/Q SPECT CT had higher specificity (93%) than V/Q SPECT alone (88%). If CT had been used as a ventilation substitute, 21% of patients would have been reported to be positive for PE (8% false-positive), yielding a specificity of 60% for Q SPECT CT. These findings align with the existing literature, although discrepancies in specificity values were noted due to the different study designs and sample sizes. Conclusion: This study highlights the enhanced specificity of V/Q SPECT CT compared to V/Q SPECT and Q SPECT CT alone. Including low-dose CT improves diagnostic accuracy by reducing false positives and providing detailed anatomical information. V/Q SPECT CT offers superior specificity in diagnosing PE compared with V/Q SPECT alone, supporting its use in clinical practice.
机构:
CHU Nancy, Nucl Med Serv, Hop Brabois, F-54511 Vandoeuvre Les Nancy, FranceCHU Nancy, Nucl Med Serv, Hop Brabois, F-54511 Vandoeuvre Les Nancy, France
Mathias, E.
Didot, N.
论文数: 0引用数: 0
h-index: 0
机构:
CHU Nancy, Nucl Med Serv, Hop Brabois, F-54511 Vandoeuvre Les Nancy, FranceCHU Nancy, Nucl Med Serv, Hop Brabois, F-54511 Vandoeuvre Les Nancy, France
Didot, N.
Karcher, G.
论文数: 0引用数: 0
h-index: 0
机构:
CHU Nancy, Nucl Med Serv, Hop Brabois, F-54511 Vandoeuvre Les Nancy, FranceCHU Nancy, Nucl Med Serv, Hop Brabois, F-54511 Vandoeuvre Les Nancy, France
Karcher, G.
Marie, P. -Y.
论文数: 0引用数: 0
h-index: 0
机构:
CHU Nancy, Nucl Med Serv, Hop Brabois, F-54511 Vandoeuvre Les Nancy, FranceCHU Nancy, Nucl Med Serv, Hop Brabois, F-54511 Vandoeuvre Les Nancy, France
机构:
Capital Med Univ, Beijing Friendship Hosp, Dept Nucl Med, Beijing 100050, Peoples R ChinaCapital Med Univ, Beijing Friendship Hosp, Dept Nucl Med, Beijing 100050, Peoples R China
Kan, Ying
Yuan, Leilei
论文数: 0引用数: 0
h-index: 0
机构:
Capital Med Univ, Beijing Friendship Hosp, Dept Nucl Med, Beijing 100050, Peoples R ChinaCapital Med Univ, Beijing Friendship Hosp, Dept Nucl Med, Beijing 100050, Peoples R China
Yuan, Leilei
Meeks, Jacqui K.
论文数: 0引用数: 0
h-index: 0
机构:
Childrens Hosp Philadelphia, Dept Radiol, Philadelphia, PA 19104 USACapital Med Univ, Beijing Friendship Hosp, Dept Nucl Med, Beijing 100050, Peoples R China
Meeks, Jacqui K.
Li, Chunlin
论文数: 0引用数: 0
h-index: 0
机构:
Capital Med Univ, Beijing Friendship Hosp, Dept Nucl Med, Beijing 100050, Peoples R ChinaCapital Med Univ, Beijing Friendship Hosp, Dept Nucl Med, Beijing 100050, Peoples R China
Li, Chunlin
Liu, Wencao
论文数: 0引用数: 0
h-index: 0
机构:
Shanxi Prov Hosp, Emergency Dept, Taiyuan, Shanxi, Peoples R ChinaCapital Med Univ, Beijing Friendship Hosp, Dept Nucl Med, Beijing 100050, Peoples R China
Liu, Wencao
Yang, Jigang
论文数: 0引用数: 0
h-index: 0
机构:
Capital Med Univ, Beijing Friendship Hosp, Dept Nucl Med, Beijing 100050, Peoples R ChinaCapital Med Univ, Beijing Friendship Hosp, Dept Nucl Med, Beijing 100050, Peoples R China
机构:
CHA Univ, CHA Bundang Med Ctr, Dept Nucl Med, Pochon, South KoreaCHA Univ, CHA Bundang Med Ctr, Dept Nucl Med, Pochon, South Korea
Bang, Ji-In
Lee, Won Woo
论文数: 0引用数: 0
h-index: 0
机构:
Seoul Natl Univ, Bundang Hosp, Coll Med, Dept Nucl Med, 82 Gumi Ro,173 Beon Gil, Seongnam 13620, South Korea
Seoul Natl Univ, Inst Radiat Med, Med Res Ctr, Seoul, South Korea
Seoul Natl Univ, Grad Sch Convergence Sci & Technol, Dept Hlth Sci & Technol, Suwon, South KoreaCHA Univ, CHA Bundang Med Ctr, Dept Nucl Med, Pochon, South Korea
Lee, Won Woo
Cho, Sang-Geon
论文数: 0引用数: 0
h-index: 0
机构:
Chonnam Natl Univ, Chonnam Natl Univ Hosp, Med Sch, Dept Nucl Med, Gwangju, South KoreaCHA Univ, CHA Bundang Med Ctr, Dept Nucl Med, Pochon, South Korea
Cho, Sang-Geon
Choi, Miyoung
论文数: 0引用数: 0
h-index: 0
机构:
Natl Evidence Based Healthcare Collaborating Agcy, Div Healthcare Technol Assessment Res, Seoul, South KoreaCHA Univ, CHA Bundang Med Ctr, Dept Nucl Med, Pochon, South Korea
Choi, Miyoung
Song, Yoo Sung
论文数: 0引用数: 0
h-index: 0
机构:
Seoul Natl Univ, Bundang Hosp, Coll Med, Dept Nucl Med, 82 Gumi Ro,173 Beon Gil, Seongnam 13620, South KoreaCHA Univ, CHA Bundang Med Ctr, Dept Nucl Med, Pochon, South Korea