Characterizing Mechanical Changes in the Biceps Brachii Muscle in Mild Facioscapulohumeral Muscular Dystrophy Using Shear Wave Elastography

被引:0
作者
Kleiser, Benedict [1 ,2 ,3 ]
Zimmer, Manuela [4 ]
Ates, Filiz [4 ]
Marquetand, Justus [1 ,2 ,3 ,5 ]
机构
[1] Univ Tubingen, Hertie Inst Clin Brain Res, Dept Epileptol, Hoppe Seyler Str 3, D-72076 Tubingen, Germany
[2] Univ Tubingen, Hertie Inst Clin Brain Res, Dept Neural Dynam & Magnetoencephalog, Otfried Muller Str 25, D-72076 Tubingen, Germany
[3] Univ Tubingen, MEG Ctr, Otfried Muller Str 47, D-72076 Tubingen, Germany
[4] Univ Stuttgart, Inst Struct Mech & Dynam Aerosp Engn, Pfaffenwaldring 27, D-70569 Stuttgart, Germany
[5] Univ Stuttgart, Inst Modelling & Simulat Biomech Syst, Pfaffenwaldring 5a, D-70569 Stuttgart, Germany
关键词
SWE; FSHD; ultrasound elastography; sEMG; skeletal muscle mechanics; ELASTIC-MODULUS; MOTOR CORTEX; STIFFNESS; FORCE; LENGTH; ULTRASOUND; SPINDLE; INDEX; AGE;
D O I
10.3390/diagnostics14171985
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
There is no general consensus on evaluating disease progression in facioscapulohumeral muscular dystrophy (FSHD). Recently, shear wave elastography (SWE) has been proposed as a noninvasive diagnostic tool to assess muscle stiffness in vivo. Therefore, this study aimed to characterize biceps brachii (BB) muscle mechanics in mild-FSHD patients using SWE. Eight patients with mild FSHD, the BB were assessed using SWE, surface electromyography (sEMG), elbow moment measurements during rest, maximum voluntary contraction (MVC), and isometric ramp contractions at 25%, 50%, and 75% MVC across five elbow positions (60 degrees, 90 degrees, 120 degrees, 150 degrees, and 180 degrees flexion). The mean absolute percentage deviation (MAPD) was analyzed as a measure of force control during ramp contractions. The shear elastic modulus of the BB in FSHD patients increased from flexed to extended elbow positions (e.g., p < 0.001 at 25% MVC) and with increasing contraction intensity (e.g., p < 0.001 at 60 degrees). MAPD was highly variable, indicating significant deviation from target values during ramp contractions. SWE in mild FSHD is influenced by contraction level and joint angle, similar to findings of previous studies in healthy subjects. Moreover, altered force control could relate to the subjective muscle weakness reported by patients with dystrophies.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Mechanical properties of ankle joint and gastrocnemius muscle in spastic children with unilateral cerebral palsy measured with shear wave elastography
    Boulard, Clement
    Gautheron, Vincent
    Lapole, Thomas
    JOURNAL OF BIOMECHANICS, 2021, 124
  • [22] Ultrasound of the Biceps Muscle in Idiopathic Parkinson's Disease with Deep Brain Stimulation: Rigidity Can Be Quantified by Shear Wave Elastography
    Oppold, Julia
    Breu, Maria-Sophie
    Gharabaghi, Alireza
    Grimm, Alexander
    Del Grosso, Nicholas A. A.
    Hormozi, Mohammad
    Kleiser, Benedict
    Klocke, Philipp
    Kronlage, Cornelius
    Weiss, Daniel
    Marquetand, Justus
    DIAGNOSTICS, 2023, 13 (02)
  • [23] Change in Shear Elastic Modulus of Thigh Muscle by Changing Muscle Length Using Ultrasound Shear Wave Elastography in Beagle Dogs
    Shimizu, Miki
    Ito, Yu
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2019, 32 (06) : 454 - 459
  • [24] Muscle and Tendon Stiffness of the Lower Limb of Professional Adolescent Soccer Athletes Measured Using Shear Wave Elastography
    Roemer, Claudia
    Czupajllo, Julia
    Zessin, Enrico
    Fischer, Thomas
    Wolfarth, Bernd
    Lerchbaumer, Markus Herbert
    DIAGNOSTICS, 2022, 12 (10)
  • [25] Quantifying cervical and axioscapular muscle stiffness using shear wave elastography
    Xie, Yanfei
    Thomas, Lucy
    Hug, Francois
    Johnston, Venerina
    Coombes, Brooke K.
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2019, 48 : 94 - 102
  • [26] Quantifying Myocardial Contractility Changes Using Ultrasound-Based Shear Wave Elastography
    Vejdani-Jahromi, Maryam
    Freedman, Jenna
    Nagle, Matthew
    Kim, Young-Joong
    Trahey, Gregg E.
    Wolf, Patrick D.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2017, 30 (01) : 90 - 96
  • [27] Quantified Mechanical Properties of the Deltoid Muscle Using the Shear Wave Elastography: Potential Implications for Reverse Shoulder Arthroplasty
    Hatta, Taku
    Giambini, Hugo
    Sukegawa, Koji
    Yamanaka, Yoshiaki
    Sperling, John W.
    Steinmann, Scott P.
    Itoi, Eiji
    An, Kai-Nan
    PLOS ONE, 2016, 11 (05):
  • [28] Quantifying the passive stretching response of human tibialis anterior muscle using shear wave elastography
    Koo, Terry K.
    Guo, Jing-Yi
    Cohen, Jeffrey H.
    Parker, Kevin J.
    CLINICAL BIOMECHANICS, 2014, 29 (01) : 33 - 39
  • [29] Application of the novel estimation method by shear wave elastography using vibrator to human skeletal muscle
    Tsuchida, Wakako
    Yamakoshi, Yoshiki
    Matsuo, Shingo
    Asakawa, Mayu
    Sugahara, Keita
    Fukaya, Taizan
    Yamanaka, Eiji
    Asai, Yuji
    Nitta, Naotaka
    Ooie, Toshihiko
    Suzuki, Shigeyuki
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [30] VISCOELASTICITY ASSESSMENT FOR IN VIVO QUANTIFICATION OF MUSCLE CONTUSION INJURY IN RATS USING SHEAR WAVE ELASTOGRAPHY
    Xin, Yuwei
    Liu, Feifei
    LI, Diancheng
    Zhu, Jiaan
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2022, 48 (10) : 2019 - 2028