Long-term adherence to a wearable for continuous behavioural activity measuring in the SafeHeart implantable cardioverter defibrillator population

被引:3
作者
Frodi, Diana My [1 ]
Kolk, Maarten Z. H. [2 ]
Langford, Joss [3 ,4 ]
Knops, Reinoud [2 ]
Tan, Hanno L. [2 ,5 ]
Andersen, Tariq Osman [6 ]
Jacobsen, Peter Karl [1 ]
Risum, Niels [1 ]
Svendsen, Jesper Hastrup [1 ,7 ]
Tjong, Fleur V. Y. [2 ]
Diederichsen, Soren Zoega [1 ]
机构
[1] Copenhagen Univ Hosp, Dept Cardiol, Rigshosp, Inge Lehmanns Vej 7, DK-2100 Copenhagen, Denmark
[2] Univ Amsterdam, Dept Clin & Expt Cardiol, Amsterdam UMC, Meibergdreef 9, NL-1105 AZ Amsterdam, Netherlands
[3] Activinsights Ltd, 6 Nene Rd,Bicton Ind Pk, Kimbolton PE28 0LF, Cambridgeshire, England
[4] Univ Exeter, Coll Life & Environm Sci, St Lukes Campus,Heavitree Rd, Exeter EX1 2LU, Devon, England
[5] Netherlands Heart Inst, Moreelsepk 1, NL-3511 EP Utrecht, Netherlands
[6] Univ Copenhagen, Dept Comp Sci, Univ Pk 1, DK-2100 Copenhagen, Denmark
[7] Univ Copenhagen, Fac Hlth & Med Sci, Dept Clin Med, Blegdamsvej 3B, DK-2100 Copenhagen, Denmark
来源
EUROPEAN HEART JOURNAL - DIGITAL HEALTH | 2024年 / 5卷 / 05期
关键词
Wearable; Implantable cardioverter defibrillator; Adherence; Prediction; Activity tracker; Long term; ATRIAL-FIBRILLATION; PHYSICAL-ACTIVITY; PREVENTION; SMARTWATCH; OUTCOMES; DEVICES;
D O I
10.1093/ehjdh/ztae055
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Wearable health technologies are increasingly popular. Yet, wearable monitoring only works when devices are worn as intended, and adherence reporting lacks standardization. In this study, we aimed to explore the long-term adherence to a wrist-worn activity tracker in the prospective SafeHeart study and identify patient characteristics associated with adherence.Methods and results This study enrolled 303 participants, instructed to wear a wrist-worn accelerometer day and night for 6 months. Long-term adherence was defined as valid days (>= 22 h of wear time) divided by expected days, and daily adherence as mean hours of wear time per 24 h period. Optimal, moderate, and low long-term and daily adherence groups were defined as long-term adherence above or below 95 and 75% and daily adherence above or below 90 and 75%. Regression models were used to identify patient characteristics associated with long-term adherence. In total, 296 participants [median age 64 years; interquartile range (IQR) 57-72; 19% female] were found eligible, yielding 44 003 days for analysis. The median long-term adherence was 88.2% (IQR 74.6-96.5%). A total of 83 (28%), 127 (42.9%), and 86 (29.1%) participants had optimal, moderate, and low long-term adherence, and 163 (55.1%), 87 (29.4%), and 46 (15.5%) had optimal, moderate, and low daily adherence, respectively. Age and smoking habits differed significantly between adherence levels, and increasing changeover intervals improved the degree of long-term adherence.Conclusion Long-term adherence to a wearable activity tracker was 88.2% over a 6-month period. Older age and longer changeover interval were positively associated with long-term adherence. This serves as a benchmark for future studies that rely on wearable devices.Trial registration number The National Trial Registration number: NL9218 (https://onderzoekmetmensen.nl/). This study explored whether patients with an increased risk of cardiac arrest were willing and able to use an advanced wristband accelerometer for continuous day-to-day collection of physical activity and behavior data to potentially predict worsening health. Graphical Abstract
引用
收藏
页码:622 / 632
页数:11
相关论文
共 36 条
[1]   Do Wearable Activity Trackers Increase Physical Activity Among Cardiac Rehabilitation Participants? A SYSTEMATIC REVIEW AND META-ANALYSIS [J].
Ashur, Carmel ;
Cascino, Thomas M. ;
Lewis, Christopher ;
Townsend, Whitney ;
Sen, Ananda ;
Pekmezi, Dorothy ;
Richardson, Caroline R. ;
Jackson, Elizabeth A. .
JOURNAL OF CARDIOPULMONARY REHABILITATION AND PREVENTION, 2021, 41 (04) :249-256
[2]  
Campbell C., 2024, GENEAclassify: Segmentation and classification of accelerometer data Internet
[3]   Reporting adherence, validity and physical activity measures of wearable activity trackers in medical research: A systematic review [J].
Chan, Alexandre ;
Chan, Daniella ;
Lee, Hui ;
Ng, Chiu Chin ;
Yeo, Angie Hui Ling .
INTERNATIONAL JOURNAL OF MEDICAL INFORMATICS, 2022, 160
[4]   Factors Affecting the Quality of Person-Generated Wearable Device Data and Associated Challenges: Rapid Systematic Review [J].
Cho, Sylvia ;
Ensari, Ipek ;
Weng, Chunhua ;
Kahn, Michael G. ;
Natarajan, Karthik .
JMIR MHEALTH AND UHEALTH, 2021, 9 (03)
[5]   Use of Wearable Activity Trackers to Improve Physical Activity Behavior in Patients With Rheumatic and Musculoskeletal Diseases: A Systematic Review and Meta-Analysis [J].
Davergne, Thomas ;
Pallot, Adrien ;
Dechartres, Agnes ;
Fautrel, Bruno ;
Gossec, Laure .
ARTHRITIS CARE & RESEARCH, 2019, 71 (06) :758-767
[6]   Use of Wearable Devices in Individuals With or at Risk for Cardiovascular Disease in the US, 2019 to 2020 [J].
Dhingra, Lovedeep S. ;
Aminorroaya, Arya ;
Oikonomou, Evangelos K. ;
Nargesi, Arash Aghajani ;
Wilson, Francis Perry ;
Krumholz, Harlan M. ;
Khera, Rohan .
JAMA NETWORK OPEN, 2023, 6 (06)
[7]   Fitbit Usage in Patients With Breast Cancer Undergoing Chemotherapy [J].
Dreher, Nickolas ;
Hadeler, Edward Kenji ;
Hartman, Sheri J. ;
Wong, Emily C. ;
Acerbi, Irene ;
Rugo, Hope S. ;
Majure, Melanie Catherine ;
Chien, Amy Jo ;
Esserman, Laura J. ;
Melisko, Michelle E. .
CLINICAL BREAST CANCER, 2019, 19 (06) :443-U207
[8]  
Elm E., 2007, BMJ-BRIT MED J, V335, P806, DOI [10.1136/bmj.39335.541782.AD, DOI 10.1016/J.JCLINEPI.2007.11.008, DOI 10.1136/BMJ.39335.541782.AD]
[9]   Age and Outcomes of Primary Prevention Implantable Cardioverter-Defibrillators in Patients With Nonischemic Systolic Heart Failure [J].
Elming, Marie Bayer ;
Nielsen, Jens C. ;
Haarbo, Jens ;
Videbaek, Lars ;
Korup, Eva ;
Signorovitch, James ;
Olesen, Line Lisbeth ;
Hildebrandt, Per ;
Steffensen, Flemming H. ;
Bruun, Niels E. ;
Eiskjaer, Hans ;
Brandes, Axel ;
Thogersen, Anna M. ;
Gustafsson, Finn ;
Egstrup, Kenneth ;
Videbaek, Regitze ;
Hassager, Christian ;
Svendsen, Jesper Hastrup ;
Hofsten, Dan E. ;
Torp-Pedersen, Christian ;
Pehrson, Steen ;
Kober, Lars ;
Thune, Jens Jakob .
CIRCULATION, 2017, 136 (19) :1772-1780
[10]   Rationale and design of the SafeHeart study: Development and testing of a mHealth tool for the prediction of arrhythmic events and implantable cardioverter-defibrillator therapy [J].
Frodi, Diana M. ;
Kolk, Maarten Z. H. ;
Langford, Joss ;
Andersen, Tariq O. ;
Knops, Reinoud E. ;
Tan, Hanno L. ;
Svendsen, Jesper H. ;
Tjong, Fleur V. Y. ;
Diederichsen, Soeren Z. .
CARDIOVASCULAR DIGITAL HEALTH JOURNAL, 2021, 2 (06) :S11-S20