In vivo and in vitro relationship between ionized magnesium and ionized calcium

被引:0
|
作者
Groenestege, Wouter M. Tiel [1 ,2 ]
Stokwielder, Ron H. [1 ,2 ]
Soels, Leosa R. [1 ,2 ]
Sikma, Maaike A. [2 ,3 ,4 ]
Hutten, Tim J. A. [1 ,2 ]
机构
[1] Univ Med Ctr Utrecht, Cent Diagnost Lab, Lab Expt Cardiol, Heidelberglaan 100,POB 85500, NL-3508 GA Utrecht, Netherlands
[2] Univ Utrecht, Utrecht, Netherlands
[3] Univ Med Ctr Utrecht, Intens Care, Utrecht, Netherlands
[4] Univ Med Ctr Utrecht, Dutch Poisons Informat Ctr, Utrecht, Netherlands
关键词
Ionized magnesium; Ionized calcium; Calcium; pH; Albumin; Interference; Ion selective electrode; NOVA MAGNESIUM; PH; AVL;
D O I
10.1016/j.clinbiochem.2024.110815
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: The objective of this study was to determine the in vivo correlation of ionized magnesium (iMg) with ionized calcium (iCa), total calcium, albumin and pH. In addition, the analytical interference of iCa on iMg measurement on the Stat Profile Prime Plus (Nova Biomedical) and vice versa was defined. Methods: In vivo correlation of iCa, iMg and pH was studied in 238 paired blood gas samples of 109 different patients admitted to the intensive care unit. Albumin and total magnesium (tMg) were measured in heparinized plasma samples. Measurement of iMg was performed with the ion selective magnesium electrode (ISE) of the Stat Profile Prime Plus (Nova Biomedical) and iCa and pH were measured with a Rapid Point 500 blood gas analyzer (Siemens). Albumin, total calcium and total magnesium were analyzed with a Siemens Atellica CH. Analytical interference of iCa with iMg and vice versa was investigated using unbuffered saline solutions. Results: In the studied patient population, no significant correlations were observed between iMg and iCa, albumin, and pH. An inverse relationship was observed between iCa and Mg-ISE. For every 0.1 mmol/L change in iCa concentration, the iMg concentration deviated by 0.01 mmol/L at an iMg concentration of 0.5 mmol/L and by 0.013 mmol/L at an iMg concentration of 1.0 mmol/L. The measurement of iCa was not affected by iMg. Conclusions: In vivo, no correlation was observed between iMg with iCa, albumin and pH. Interference of iCa on iMg measurement was noted, with a maximum deviation of +/- 0.02 mmol/L iMg across the reference range of iCa (1.15-1.32 mmol/L). Additionally, the iCa measurement was not affected by the iMg concentration.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] IFCC guideline for sampling, measuring and reporting ionized magnesium in plasma
    Ben Rayana, Mohammed C.
    Burnett, Robert W.
    Covington, Arthur K.
    D'Orazio, Paul
    Fogh-Andersen, Niels
    Jacobs, Ellis
    Kulpmann, Wolf R.
    Kuwa, Katsuhiko
    Larsson, Lasse
    Lewenstam, Andrzej
    Maas, Anton H. J.
    Mager, Gerhard
    Naskalski, Jerzy W.
    Okorodudu, Anthony O.
    Ritter, Christoph
    St John, Andrew
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2008, 46 (01) : 21 - 26
  • [2] The Influence of Albumin and pH on Total and Ionized Calcium and Magnesium
    Dimeski, Goce
    Treacy, Oliver
    POINT OF CARE, 2018, 17 (04): : 123 - 126
  • [3] Effect of Bicarbonate on Neonatal Serum Ionized Magnesium In Vivo
    Glatstein, Miguel
    Mimouni, Francis B.
    Dollberg, Shaul
    Mandel, Dror
    AMERICAN JOURNAL OF THERAPEUTICS, 2011, 18 (06) : 463 - 465
  • [4] Decreased ionized magnesium and an increased ionized calcium-magnesium ratio in elderly hypertensives
    Kisters, Klaus
    Kisters, Lukas
    Micke, Oliver
    Muecke, Ralph
    Porta, Sepp
    Noack, Thomas
    Groeber, Uwe
    TRACE ELEMENTS AND ELECTROLYTES, 2022, 39 (03) : 95 - 98
  • [5] Serum ionized magnesium and calcium in women after menopause: inverse relation of estrogen with ionized magnesium
    Muneyyirci-Delale, O
    Nacharaju, VL
    Dalloul, M
    Altura, BM
    Altura, BT
    FERTILITY AND STERILITY, 1999, 71 (05) : 869 - 872
  • [6] Ionized calcium
    Baird, Geoffrey S.
    CLINICA CHIMICA ACTA, 2011, 412 (9-10) : 696 - 701
  • [7] SPECIFIC HEPARIN PREPARATIONS INTERFERE WITH THE SIMULTANEOUS MEASUREMENT OF IONIZED MAGNESIUM AND IONIZED CALCIUM
    LYON, ME
    BREMNER, D
    LAHA, T
    MALIK, S
    HENDERSON, PJ
    KENNY, MA
    CLINICAL BIOCHEMISTRY, 1995, 28 (01) : 79 - 84
  • [8] Ionized calcium measurements are influenced by albumin - should ionized calcium be corrected?
    Larsen, Trine R.
    Galthen-Sorensen, Mathias
    Antonsen, Steen
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2014, 74 (06) : 515 - 523
  • [9] Guidelines for sampling, measuring and reporting ionized magnesium in undiluted serum, plasma or blood
    Ben Rayana, MC
    Burnett, RW
    Covington, AK
    D'Orazio, P
    Fogh-Andersen, N
    Jacobs, E
    Külpmann, WR
    Kuwa, K
    Larsson, L
    Lewenstam, A
    Maas, AHJ
    Mager, G
    Naskalski, JHJ
    Okorodudu, AO
    Ritter, C
    St John, A
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2005, 43 (05) : 564 - 569
  • [10] Effect of Magnesium Sulfate Concentration on Serum Ionized Magnesium In Vitro
    Salamon, Mia
    Mimouni, Francis B.
    Dollberg, Shaul
    Mandel, Dror
    AMERICAN JOURNAL OF PERINATOLOGY, 2010, 27 (07) : 525 - 528