Performance analysis of a novel air filtration and sterilization PV-Trombe wall

被引:1
|
作者
Xie, Hao [1 ,2 ]
Jia, Hengmin [3 ]
Ji, Jie [1 ,2 ]
Qian, Yu [1 ,2 ]
Meng, Hongju [1 ,2 ]
Li, Jiyao [1 ,2 ]
Mu, Yan [3 ]
机构
[1] Univ Sci & Technol China, Dept Thermal Sci & Energy Engn, Hefei 230026, Anhui, Peoples R China
[2] Key Lab Solar Thermal Convers Anhui Prov, Hefei 230026, Anhui, Peoples R China
[3] Univ Sci & Technol China, Affiliated Hosp USTC 1, Dept Infect Control, Div Life Sci & Med, Hefei 230001, Peoples R China
基金
中国国家自然科学基金;
关键词
Solar energy; PV-Trombe wall; Bioaerosol; Thermal sterilization; Infection control; c specific heat capacity; J/(kg & sdot; K); Greeks; HEAT-TRANSFER; INACTIVATION; SYSTEM; FLOW; FILTER; BIOAEROSOLS; MODEL; ROOM;
D O I
10.1016/j.buildenv.2024.111953
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Bioaerosols have received widespread attention since the outbreak of Coronavirus Disease 2019 owing to their harmful effect on public health. To deal with indoor bioaerosols in an energy-saving method, an air filtration and sterilization PV-Trombe wall was proposed in this study. An experiment rig concerning thermal sterilization of aerosolized Klebsiella pneumoniae was set up to test its feasibility and effectiveness at different exposure temperature and residence time. With the experimental data, an inactivation model was derived based on the first kinetic model and Arrhenius equation. Besides, a mathematic model concerning heat and mass transfer was established for simulating the system performance at different conditions. The results reveal that: (1) The survival ratio of bioaerosols was 0.848, 0.689, 0.493 and 0.257 for the exposure temperature of 45 degrees C, 60 degrees C, 73 degrees C and 85 degrees C at the residence time of 6.5 s (2) the survival ratio predicted by the inactivation model corresponded well with the experimental results and the root mean square error was 0.041. (3) The electrical and thermal efficiencies were 0.134 and 0.218 while the indoor bacterial concentration was reduced by over 60 % with bacterial quantity of filter maintained at a low level. (4) The increase of air velocity could significantly improve the purification performance.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] CFD modeling and experimental validation of the thermal performance of a novel dynamic PCM Trombe wall: Comparison with the companion static wall with and without PCM
    Zhou, Shiqiang
    Razaqpur, A. Ghani
    APPLIED ENERGY, 2024, 353
  • [42] A novel passive solar vertical-finned-thermocatalytic-Trombe wall system for air purification and heating
    Wu, Shuang-Ying
    Yan, Rong-Rong
    Xiao, Lan
    JOURNAL OF CLEANER PRODUCTION, 2022, 374
  • [43] Study on a high-performance photocatalytic-Trombe wall system for space heating and air purification
    Yu, Bendong
    Hou, Jingxin
    He, Wei
    Liu, Shanshan
    Hu, Zhongting
    Ji, Jie
    Chen, Hongbing
    Xu, Gang
    APPLIED ENERGY, 2018, 226 : 365 - 380
  • [44] Air purification and thermal performance of photocatalytic-Trombe wall based on multiple physical fields coupling
    Wu, Shuang-Ying
    Xu, Li
    Xiao, Lan
    RENEWABLE ENERGY, 2020, 148 : 338 - 348
  • [45] Minimizing energy losses and enhancing performance of Trombe wall systems through partial evacuation of the air gap
    Ali, Mahmud Hussain
    Mawlood, Mahmood Khalid
    Jalal, Rawand Ehsan
    ENERGY AND BUILDINGS, 2024, 307
  • [46] Three-dimensional simulation on the thermal performance of a novel Trombe wall with venetian blind structure
    Hong, Xiaoqiang
    He, Wei
    Hu, Zhongting
    Wang, Chenchen
    Ji, Jie
    ENERGY AND BUILDINGS, 2015, 89 : 32 - 38
  • [47] Thermal performance analysis of a Trombe wall with the multi-row channel PCM wallboard
    Li, Yazi
    Lei, Yonggang
    Yan, Yao
    Song, Chongfang
    ENERGY, 2024, 313
  • [48] Performance analysis on a wood-color thermal catalytic Trombe wall in wood buildings
    Wu, Huabo
    Li, Niansi
    Zhang, Guoyu
    Zhang, Guoji
    Ji, Jie
    Yu, Bendong
    ENERGY AND BUILDINGS, 2024, 308
  • [49] Thermal performance and ventilation analysis of a zigzag Trombe wall: Full numerical and experimental investigations
    Zhang, Hong-Liang
    Li, Bin
    Shi, Dun-Ke
    Zhao, Fu-Yun
    ENERGY AND BUILDINGS, 2024, 306
  • [50] Numerical analysis on the cooling performance of a ventilated Trombe wall combined with venetian blinds in an office building
    Hu, Zhongting
    He, Wei
    Hong, Xiaoqiang
    Ji, Jie
    Shen, Zhihe
    ENERGY AND BUILDINGS, 2016, 126 : 14 - 27