Watchman vs. Amulet for Left Atrial Appendage Closure: Current Evidence and Future Perspectives

被引:0
作者
Frazzetto, Marco [1 ]
Sanfilippo, Claudio [1 ]
Costa, Giuliano [1 ]
Contrafatto, Claudia [1 ]
Giacalone, Chiara [1 ]
Scandura, Salvatore [1 ]
Castania, Giuseppe [1 ]
De Santis, Jessica [1 ]
Sanfilippo, Maria [1 ]
Di Salvo, Maria Elena [1 ]
Tamburino, Corrado [1 ]
Barbanti, Marco [2 ,3 ]
Grasso, Carmelo [1 ]
机构
[1] AOU Policlin G Rodolico San Marco, Div Cardiol, I-95123 Catania, Italy
[2] Univ Enna Kore, Fac Med & Surg, I-94100 Enna, Italy
[3] Osped Umberto I, Div Cardiol, ASP 4 Enna, I-94100 Enna, Italy
关键词
atrial fibrillation; left atrial appendage closure; Watchman; Amulet; ANTIPLATELET THERAPY; INTRACARDIAC ECHOCARDIOGRAPHY; STROKE PROPHYLAXIS; LAA CLOSURE; FIBRILLATION; DEVICE; OCCLUSION; EFFICACY; OUTCOMES; SAFETY;
D O I
10.3390/jcm13164651
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Left atrial appendage closure (LAAC) is a crucial intervention for stroke prevention in patients with non-valvular atrial fibrillation who are unsuitable for long-term anticoagulation. Amulet and Watchman are the most implanted devices worldwide for performing LAAC, and the aim of this review is to provide a comprehensive comparison focusing on their efficacy, safety, and short- and long-term outcomes. The Watchman device, the first to gain FDA approval, has been extensively studied and demonstrates significant reductions in stroke and systemic embolism rates. The Amulet device, a newer alternative, promises enhanced design features for more efficient appendage sealing. Current data highlight that both devices offer similar efficacy and safety for LAAC. While the two devices differ in terms of intraprocedural complication rates, they offer similar short- to long-term outcomes in terms of peri-device leaks, device-related thrombosis, and mortality. Both devices are indicated for patients who are unable to tolerate OAC, given their similar risk and safety profiles. Newer clinical studies are directed at establishing the efficacy of both devices as the primary method for stroke prevention in AF as an alternative to OAC.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] Left Atrial Appendage Closure Therapy Overview and Future Perspective
    Nasr, George H.
    Rushworth, Parker M.
    Donaldson, David M.
    CARDIOLOGY CLINICS, 2024, 42 (03) : 389 - 401
  • [42] Overcoming barriers for left atrial appendage thrombus: a systematic review of left atrial appendage closure
    Zhang, Zixi
    Zhou, Jiabao
    Lin, Qiuzhen
    Wang, Cancan
    Huang, Yunying
    Dai, Yongguo
    Zuo, Wanyun
    Liu, Na
    Xiao, Yichao
    Liu, Qiming
    BMC CARDIOVASCULAR DISORDERS, 2024, 24 (01)
  • [43] EWOLUTION of WATCHMAN Left Atrial Appendage Closure to Patients With Contraindication to Oral Anticoagulation
    Turagam, Mohit K.
    Reddy, Vivek Y.
    Dukkipati, Srinivas R.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2019, 12 (04)
  • [44] Review on Future Targets and Current Trends in Transcatheter Left Atrial Appendage Closure
    Nicholas S. Amoroso
    Current Cardiovascular Risk Reports, 2019, 13
  • [45] Predictors of thrombus formation after percutaneous left atrial appendage closure using the WATCHMAN device
    Kaneko, Hidehiro
    Neuss, Michael
    Weissenborn, Jens
    Butter, Christian
    HEART AND VESSELS, 2017, 32 (09) : 1137 - 1143
  • [46] Double device left atrial appendage closure with the WATCHMAN™
    Liu, Zheng
    Yu, Jiangtao
    Fang, Pi-hua
    He, Jia
    Wang, Jian-de
    Wang, Hao
    Tang, Min
    Zhang, Jing-tao
    Lv, Bin
    Shu, Zhang
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 187 : 281 - 282
  • [47] Antithrombotic Therapy after Percutaneous Left Atrial Appendage Closure: Evidence, Challenges and Future Directions
    Galea, Roberto
    Raeber, Lorenz
    REVIEWS IN CARDIOVASCULAR MEDICINE, 2023, 24 (12)
  • [48] Design and Rationale of the Swiss-Apero Randomized Clinical Trial: Comparison of Amplatzer Amulet vs Watchman Device in Patients Undergoing Left Atrial Appendage Closure
    Roberto Galea
    Federico De Marco
    Adel Aminian
    Nicolas Meneveau
    Frederic Anselme
    Christoph Gräni
    Adrian T. Huber
    Emmanuel Teiger
    Xavier Iriart
    Marco Angelillis
    Nicolas Brugger
    Alessandro Spirito
    Noé Corpataux
    Anna Franzone
    Pascal Vranckx
    Urs Fischer
    Giovanni Pedrazzini
    Francesco Bedogni
    Stephan Windecker
    Lorenz Räber
    Marco Valgimigli
    Journal of Cardiovascular Translational Research, 2021, 14 : 930 - 940
  • [49] Frailty in patients undergoing percutaneous left atrial appendage closure
    Wang, Allen
    Ferro, Enrico G.
    Song, Yang
    Xu, Jiaman
    Sun, Tianyu
    Yeh, Robert W.
    Strom, Jordan B.
    Kramer, Daniel B.
    HEART RHYTHM, 2022, 19 (05) : 814 - 821
  • [50] Short-term safety and efficacy of left atrial appendage closure with the WATCHMAN device in patients with small left atrial appendage ostia
    Venkataraman, Ganesh
    Strickberger, S. Adam
    Doshi, Shephal
    Ellis, Christopher R.
    Lakkireddy, Dhanunjaya
    Whalen, S. Patrick
    Cuoco, Frank
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2018, 29 (01) : 17 - 21