Experimental investigation of humidified air condensation in different rows of serpantine heat exchanger - Cooling water flow rate effect

被引:0
作者
Poskas, Robertas [1 ]
Sirvydas, Arunas [1 ]
Salem, Mohab [1 ]
Poskas, Povilas [1 ]
Jouhara, Hussam [2 ]
机构
[1] Lithuanian Energy Inst, Nucl Engn Lab, Breslaujos 3, LT-44403 Kaunas, Lithuania
[2] Brunel Univ London, Coll Engn Design & Phys Sci, Heat Pipe & Thermal Management Res Grp, Uxbridge UB8 3PH, England
关键词
Condensation; Humidified air; Crossflow; Cooling ratio; Local heat transfer; LAMINAR FILMWISE CONDENSATION; VAPOR;
D O I
10.1016/j.tsep.2024.102814
中图分类号
O414.1 [热力学];
学科分类号
摘要
Condensing economizers are used in the industry as they enable the acquisition of additional heat during vapor condensation. In condensing heat exchangers, water is the usual cooling agent due to its high specific heat capacity and thus efficient heat removal. Therefore, experiments of hot humid air condensation in a serpentine economizer being cooled by water were performed to reveal the effect the cooling water flow rate has on humidified air condensation in separate rows of the serpentine type economizer (with vertical tubes). The results have shown that the cooling ratio (mass flow ratio between the coolant and the humid air) had a minor effect on the distribution of the humidified air temperature along test section for inlet Reynolds number of 3000-10000. The effects on the condensation flux distribution in different rows were much stronger. The most optimal cooling ratio was determined to be 3. The results have shown that the biggest condensation efficiency is up to 35 %. It was revealed that in some cases the convection was prevailing in the first rows of the economizer and this resulted in a decreased efficiency/performance of the exchanger. The obtained results from the practical point of view will provide an extended basis for the optimisation of the design of economizers for waste heat recovery in the cases of different cooling water flow rates. It could also be applied to validate computational models developed for condensation heat transfer and condensate flux numerical modelling along economizer.
引用
收藏
页数:15
相关论文
共 31 条
[1]  
Ahmed A., 2022, Int. J. Innov. Sci. Technol., V3, DOI [10.33411/ijist/2021030506, DOI 10.33411/IJIST/2021030506]
[2]  
[Anonymous], 2013, China Electricity Council
[3]  
Barford N.C., 1985, EXPT MEASUREMENTS PR
[4]   USING AIR FOR INCREASING THE DEPTH OF THE FLUE GAS HEAT RECOVERY [J].
Bespalov, Victor ;
Beljaev, Leonid ;
Melnikov, Denis .
SMART GRIDS 2015, 2015, 37
[5]   Heat and mass transfer characteristics of simulated high moisture flue gases [J].
Che, DF ;
Da, YD ;
Zhuang, ZN .
HEAT AND MASS TRANSFER, 2005, 41 (03) :250-256
[6]  
Egilegor B., 2020, International Journal of Thermofluids, P1, DOI [10.1016/j.ijft.2019.100002, DOI 10.1016/J.IJFT.2019.100002]
[7]  
Fierro JJ., 2020, International Journal of Thermofluids, V7-8, P100040, DOI [DOI 10.1016/J.IJFT.2020.100040, 10.1016/J. IJFT.2020.100040]
[8]   HEAT-TRANSFER AND FLOW RESISTANCE IN CONDENSATION OF LOW-PRESSURE STEAM FLOWING THROUGH TUBE BANKS [J].
FUJII, T ;
UEHARA, H ;
HIRATA, K ;
ODA, K .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1972, 15 (02) :247-&
[9]   HEAT-TRANSFER AND FLOW RESISTANCE IN CONDENSATION OF LOW-PRESSURE STEAM FLOWING THROUGH TUBE BANKS [J].
FUJII, T ;
UEHARA, H ;
HIRATA, K ;
ODA, K .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1972, 15 (02) :247-&
[10]   HEAT-TRANSFER AND FLOW RESISTANCE IN CONDENSATION OF LOW-PRESSURE STEAM FLOWING THROUGH TUBE BANKS [J].
FUJII, T ;
UEHARA, H ;
HIRATA, K ;
ODA, K .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1972, 15 (02) :247-&