Comparative Study of the Normalized-Error-Based Control and Traditional Current-Mode Control for a Sixth-Order Boost Converter

被引:0
|
作者
Mishra, Avinash [1 ]
Mandal, Sanjoy [1 ]
Tatini, Narendra Babu [2 ]
Gunnam, Leenendra Chowdary [3 ]
Chincholkar, Satyajit Hemant [4 ]
机构
[1] Indian Inst Technol ISM Dhanbad, Dept Elect Engn, Dhanbad 826004, Jharkhand, India
[2] Koneru Lakshmaiah Educ Fdn, Dept Internet Things, Guntur 522302, Andhra Pradesh, India
[3] SRM Univ AP, Dept Elect & Commun Engn, Amaravati 522240, Andhra Pradesh, India
[4] MIT Acad Engn, Sch E&TC Engn, Dept Elect & Telecommun Engn, Pune 412105, India
来源
IEEE ACCESS | 2024年 / 12卷
关键词
Topology; Stability analysis; Voltage control; Renewable energy sources; DC-DC power converters; Transient response; Inductors; High-order boost converter; current-mode control; normalized-error; DC-DC CONVERTER;
D O I
10.1109/ACCESS.2024.3431614
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Current-mode control is a commonly utilized control strategy for the step-up power converters because these converters' control-to-output transfer function contains right-half plane zeros. The main concern associated with the recent dual-loop current-mode controller (CMC) is that the integrator operates on the error term itself. Thus, integrand can assume extremely large values when error is large such as during transient response, and the controller output may saturate, especially when sufficiently large controller gains are used. If lower gain values of gains are used, the speed of response in the presence of small parameter variations could be much lower. Thus, there is a compromise between the transient response when error signal is large and speed of the response for small error signals. To address these concerns, an improved normalized-error based current-mode controller (NECC) is employed for voltage regulation in a sixth-order boost configuration. This controller's main characteristic is that the integrator now operates on a bounded integrand which is a normalized-error. This avoids the integrator saturation and also increase the room for tuning the controller gains. The state-space averaged model of the topology is given and a detailed stability analysis is shown. The main contribution of the paper is that a detailed comparative study of the traditional CMC and an improved NECC based on some simulation and experimental waveforms is provided. Both simulation and experimental outcomes clearly prove the superiority of the proposed NECC in terms of an improved speed and less overshoot of the output voltage response.
引用
收藏
页码:102178 / 102187
页数:10
相关论文
共 50 条
  • [31] A High-Performance Current-Mode DC-DC Buck Converter with Adaptive Clock Control Technique
    Chiu, You-Te
    Liu, Yu-Hsuan
    Hung, Chung-Chih
    2018 INTERNATIONAL SYMPOSIUM ON VLSI DESIGN, AUTOMATION AND TEST (VLSI-DAT), 2018,
  • [32] Designing a Dynamic Ramp With an Invariant Inductor in Current-Mode Control for an On-Chip Buck Converter
    Chen, Wen-Wei
    Chen, Jiann-Fuh
    Liang, Tsorng-Juu
    Wei, Lu-Chi
    Ting, Wei-Yuan
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (02) : 750 - 758
  • [33] Adaptive Current-Mode Control of a High Step-Up DC-DC Converter
    Chan, Chok-You
    Chincholkar, Satyajit Hemant
    Jiang, Wentao
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (09) : 7297 - 7305
  • [34] Sensorless current-mode control of a digital dead-beat DC-DC converter
    Kelly, A
    Rinne, K
    APEC 2004: NINETEENTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, VOLS 1-3, 2004, : 1790 - 1795
  • [35] Control of a Photovoltaic Array Interfacing Current-Mode-Controlled Boost Converter Based on Virtual Impedance Emulation
    Urtasun, Andoni
    Samanes, Javier
    Barrios, Ernesto L.
    Sanchis, Pablo
    Marroyo, Luis
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2019, 66 (05) : 3496 - 3506
  • [36] Sensorless Ripple Current Mode Control to Achieve Inductor-Deviation-Tolerant BCM Operation for Boost Converter
    Lyu, Dian
    Li, Linkai
    Li, Songke
    Min, Run
    Wang, Yinyu
    Zhang, Desheng
    Tong, Qiaoling
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2020, 35 (11) : 12359 - 12369
  • [37] A novel peak and deep current mode control for two switches buck-boost converter
    Ahmad, Ahmad Ale
    Abrishamifar, Adib
    Fazeli, Mehdi
    APEC 2008: TWENTY-THIRD ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, VOLS 1-4, 2008, : 1093 - +
  • [38] Investigation of ultra-lift Luo-converter with peak, average and hysteresis current-mode control
    Raji, J.
    Kamaraj, V.
    JOURNAL OF POWER ELECTRONICS, 2021, 21 (06) : 951 - 963
  • [39] Investigation of ultra-lift Luo-converter with peak, average and hysteresis current-mode control
    J. Raji
    V. Kamaraj
    Journal of Power Electronics, 2021, 21 : 951 - 963
  • [40] A Monolithic High-Performance Buck Converter With Enhanced Current-Mode Control and Advanced Protection Circuits
    Wang, Lang-Yuan
    Zhao, Meng-Lian
    Wu, Xiao-Bo
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2016, 31 (01) : 793 - 805