Comparative Study of the Normalized-Error-Based Control and Traditional Current-Mode Control for a Sixth-Order Boost Converter

被引:0
|
作者
Mishra, Avinash [1 ]
Mandal, Sanjoy [1 ]
Tatini, Narendra Babu [2 ]
Gunnam, Leenendra Chowdary [3 ]
Chincholkar, Satyajit Hemant [4 ]
机构
[1] Indian Inst Technol ISM Dhanbad, Dept Elect Engn, Dhanbad 826004, Jharkhand, India
[2] Koneru Lakshmaiah Educ Fdn, Dept Internet Things, Guntur 522302, Andhra Pradesh, India
[3] SRM Univ AP, Dept Elect & Commun Engn, Amaravati 522240, Andhra Pradesh, India
[4] MIT Acad Engn, Sch E&TC Engn, Dept Elect & Telecommun Engn, Pune 412105, India
来源
IEEE ACCESS | 2024年 / 12卷
关键词
Topology; Stability analysis; Voltage control; Renewable energy sources; DC-DC power converters; Transient response; Inductors; High-order boost converter; current-mode control; normalized-error; DC-DC CONVERTER;
D O I
10.1109/ACCESS.2024.3431614
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Current-mode control is a commonly utilized control strategy for the step-up power converters because these converters' control-to-output transfer function contains right-half plane zeros. The main concern associated with the recent dual-loop current-mode controller (CMC) is that the integrator operates on the error term itself. Thus, integrand can assume extremely large values when error is large such as during transient response, and the controller output may saturate, especially when sufficiently large controller gains are used. If lower gain values of gains are used, the speed of response in the presence of small parameter variations could be much lower. Thus, there is a compromise between the transient response when error signal is large and speed of the response for small error signals. To address these concerns, an improved normalized-error based current-mode controller (NECC) is employed for voltage regulation in a sixth-order boost configuration. This controller's main characteristic is that the integrator now operates on a bounded integrand which is a normalized-error. This avoids the integrator saturation and also increase the room for tuning the controller gains. The state-space averaged model of the topology is given and a detailed stability analysis is shown. The main contribution of the paper is that a detailed comparative study of the traditional CMC and an improved NECC based on some simulation and experimental waveforms is provided. Both simulation and experimental outcomes clearly prove the superiority of the proposed NECC in terms of an improved speed and less overshoot of the output voltage response.
引用
收藏
页码:102178 / 102187
页数:10
相关论文
共 50 条
  • [21] Performance Analysis of Integer and Fractional Order Current Mode Control Strategies Applied to Boost Power Converter
    Karanjkar, Dnyaneshwar S.
    Chatterji, S.
    Shimi, S. L.
    Kumar, Amod
    2013 INTERNATIONAL CONFERENCE ON ADVANCES IN TECHNOLOGY AND ENGINEERING (ICATE), 2013,
  • [22] Coexistence of Solutions in a Boost-Flyback Converter with Current Mode Control
    Munoz, Juan-Guillermo
    Gallo, Guillermo
    Angulo, Fabiola
    Osorio, Gustavo
    2017 IEEE 8TH LATIN AMERICAN SYMPOSIUM ON CIRCUITS & SYSTEMS (LASCAS), 2017,
  • [23] Corrective frequency compensation for parasitics in boost power converter with sensorless current mode control
    Min, Run
    Tong, Qiaoling
    Zhang, Qiao
    Chen, Chen
    Zou, Xuecheng
    Lv, Dian
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2018, 96 : 274 - 281
  • [24] Average current-mode control scheme for a quadratic buck converter with a single switch
    Morales-Saldana, Jorge Alberto
    Leyva-Ramos, Jesus
    Carbajal-Gutierrez, Enrique Eduardo
    Lopez, Ma. Guadalupe Ortiz
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2008, 23 (01) : 485 - 490
  • [25] Internal Model Control Scheme-Based Voltage and Current Mode Control of DC-DC Boost Converter
    Verma, Purnima
    Anwar, Md. Nishat
    Ram, Mantu Kumar
    Iqbal, Atif
    IEEE ACCESS, 2023, 11 : 110558 - 110569
  • [26] Current Tracking Delay Effect Minimization for Digital Peak Current Mode Control of DC DC Boost Converter
    Zhang, Xiaofeng
    Min, Run
    Lyu, Dian
    Zhang, Donglai
    Wang, Yi
    Gu, Yu
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2019, 34 (12) : 12384 - 12395
  • [27] LQR-based control of parallel-connected boost dc-dc converters: a comparison with classical current-mode control
    Al-Mothafar, M. R. D.
    Radaideh, S. M.
    Abdullah, M. A.
    INTERNATIONAL JOURNAL OF COMPUTER APPLICATIONS IN TECHNOLOGY, 2012, 45 (01) : 15 - 27
  • [28] A Compact High-Efficiency Boost Converter With Time-Based Control, RHP Zero-Elimination, and Tracking Error Compensation
    Leoncini, Mauro
    Dago, Alessandro
    Bertolini, Alessandro
    Gasparini, Alessandro
    Levantino, Salvatore
    Ghioni, Massimo
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2023, 38 (03) : 3100 - 3113
  • [29] Open-loop power-stage transfer functions relevant to current-mode control of boost PWM converter operating in CCM
    Bryant, B
    Kazimierczuk, MK
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, 2005, 52 (10) : 2158 - 2164
  • [30] Control of a Photovoltaic Array Interfacing Current Mode Controlled Boost Converter based on Virtual Resistance Emulation
    Urtasun, Andoni
    Sanchis, Pablo
    Marroyo, Luis
    PROCEEDINGS OF THE IECON 2016 - 42ND ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2016, : 3046 - 3051