A novel contingency screening and ranking index for grid-forming converter-based sources following generator outage

被引:0
|
作者
Yogarathnam, Amirthagunaraj [1 ]
Karunaratne, Lilan [2 ]
Chaudhuri, Nilanjan Ray [2 ]
Yue, Meng [1 ]
机构
[1] Brookhaven Natl Lab, Interdisciplinary Sci Dept, Upton, NY 11973 USA
[2] Penn State Univ, Sch Elect Engn & Comp Sci, University Pk, PA 16802 USA
关键词
DC-link voltage collapse; DC-side current limit; Dynamic security assessment; Generator outage; Grid-forming converter; Online contingency screening and ranking; Power tracing algorithm; POWER; INVERTERS; STABILITY; SYSTEM;
D O I
10.1016/j.ijepes.2024.110141
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
With the current trend, the power generation in the future power grids is expected to consist of a large number of converter-interfaced generations (CIGs) with a small percentage of synchronous generators (SGs) producing power from hydro, solar thermal, or even nuclear resources. These notable changes pose significant challenges to the secure operation of the power grid. One such issue is new cascading failure mechanisms introduced by CIGs, especially due to the dc-link voltage collapse in a dc-current limited grid-forming converter (GFC) following a generation outage. Therefore, in the online dynamic security assessment (DSA), the system operators would be interested in knowing the critical outages that may trigger this cascading mechanism in the system. To address this issue, this paper presents a contingency screening and ranking approach (which can be a part of a DSA) for generator outages in a modern grid that consists of SGs and GFCs. Our specific focus is to identify the critical outages that may lead to a cascading failure in the system due to a dc-voltage collapse in the GFCs. To that end, first, a novel contingency screening and ranking index for an (N-1) contingency scenario (i.e., outage of a single generator) is derived based on the traditional generator power tracing algorithm. Then, it is shown that the proposed ranking index can be extended to any (N-k) contingency scenarios. Finally, the effectiveness of the proposed approach following generator outages (up to (N-2) contingencies) is demonstrated using detailed time-domain simulations in two different modified test configurations of a 16-machine 68-bus New York-New England test system with GFCs using the MATLAB/Simulink platform.
引用
收藏
页数:13
相关论文
共 4 条
  • [1] An novel oscillation suppression strategy for permanent magnetic synchronous generator based on grid-forming control
    Ren, Bixing
    Li, Qiang
    Zou, Xiaoming
    Wang, Chenggen
    Jia, Yongyong
    ENERGY REPORTS, 2024, 11 : 3163 - 3170
  • [2] Small signal analysis of a grid-forming modular multilevel converter with a novel virtual synchronous generator control
    Jiang, Chen
    Sinkar, Ajinkya D.
    Gole, Aniruddha M.
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 223
  • [3] Adaptive-Observer-Based Control of a Real-World Grid-Forming Converter-Interfaced Shaft Generator in a Shipboard Microgrid
    Nam, Seungwan
    Kim, Jun-Soo
    Kim, Young-Jin
    Gomis-Bellmunt, Oriol
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2024, 71 (09) : 11429 - 11440
  • [4] Analysis of Influence of Grid-Following and Grid-Forming Static Var Generators on High-Frequency Resonance in Doubly Fed Induction Generator-Based Wind Farms
    Sun, Yong
    Wu, Hongbin
    Song, Xiaozhe
    Zhang, Haifeng
    Zhang, Yifu
    Chen, Jikai
    Liu, Hongpeng
    ELECTRONICS, 2024, 13 (19)