Phase classification and transient effects of the start-up process of multi-functional pump station in pump mode

被引:2
|
作者
Zhang, Xiaowen [1 ,2 ,3 ]
Pavesi, Giorgio [2 ]
Xu, Zhe [2 ]
Song, Xijie [1 ]
Tang, Fangping [1 ,2 ]
机构
[1] Yangzhou Univ, Coll Hydraul Sci & Engn, Yangzhou 225009, Peoples R China
[2] Univ Padua, Dept Ind Engn, Via Venezia 1, I-35131 Padua, Italy
[3] Hydrodynam Engn Lab Jiangsu Prov, Yangzhou 225009, Peoples R China
基金
中国国家自然科学基金;
关键词
Multi-functional pump station; Pump mode; Start-up process; Steady-state full characteristic experiment; Transient effect; Phase classification; VORTEX IDENTIFICATION; NUMERICAL-SIMULATION; DYNAMICS; FLOW;
D O I
10.1016/j.est.2024.113517
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In the context of achieving the goal of carbon neutrality, multi-functional pump stations (MFPS) have been greatly developed as a new energy system in recent years. The MFPS can operate in forward direction in pump mode to pump water and in turbine mode in reverse direction to generate electricity. At present, the instability of the MFPS during start-up process (SUP) in pump mode has become the key to restricting the operating life and further development of MFPS. In this paper, based on the motion characteristics of the pump and the cut-off facility (COF), the SUP of the MFPS in pump mode is clearly classified. In order to reveal the transient effect during the SUP, the steady-state full characteristic experiment (SFCE) of the pump was carried out. The occurrence phase of the transient effect during the SUP is analyzed, and the deviation between the steady-state external characteristics and the transient characteristics is revealed. In this study, the evaluation formula of the start-up completion degree (SUCD) of the MFPS in pump mode is proposed for the first time, and the evaluation and identification of the start-up progress at different phases are completed. The results show that the water flow in the system is in a reverse flow state in the Phase I. The SUCD of Phase I is 17 %. In the Phase II, The high-speed jet flow in the pump flows to the inlet of the guide vane (GV), which gradually changes the mainstream direction in the GV. A certain vortex structure can be observed at the exit of the flap gate (FG). The SUCD of Phase II is 61 %. In the Phase I and II, the dimensionless head of transient simulation is much larger than that of SFCE. In the Phase III, the flow state in the impeller will gradually stabilize. The transient effect disappears and the pressure fluctuation intensity decreases. The SUCD of Phase III is 93 %. In the Phase IV, the separation vortex that persists from Phase I-III at the tail of the GV blades disappears. The diversion capacity at the gate increases, and significant annular flow can be observed near the FG.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Transient characteristics of centrifugal pump as turbine in its start-up process
    Chai B.
    Yang J.
    Wang X.
    Jiang B.
    Yang, Junhu, 1600, Chinese Vibration Engineering Society (40): : 38 - 43and57
  • [2] Numerical Simulation of Transient Characteristics of Start-Up Transition Process of Large Vertical Siphon Axial Flow Pump Station
    Zhang, Xiaowen
    Tang, Fangping
    Liu, Chao
    Shi, Lijian
    Liu, Haiyu
    Sun, Zhuangzhuang
    Hu, Wenzhu
    FRONTIERS IN ENERGY RESEARCH, 2021, 9
  • [3] Research on the Transient Hydraulic Characteristics of Multistage Centrifugal Pump During Start-Up Process
    Long, Yun
    Lin, Bin
    Fang, Jie
    Zhu, Rongsheng
    Fu, Qiang
    FRONTIERS IN ENERGY RESEARCH, 2020, 8
  • [4] Theoretical model of transient mixed-flow pump start-up
    Lu, Yangping
    Ma, Can
    Tan, Lei
    Han, Yadong
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 2022, 62 (12): : 1938 - 1944
  • [5] Start-up of a Varspeed Group in Pump Mode, Practical Implementations and Tests
    Maendly, T.
    Hodder, A.
    Kawkabani, B.
    2016 XXII INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), 2016, : 1201 - 1207
  • [6] Some effects of start-up transient loads on shoe bearings for large hydraulic pump turbines
    Pistner, CA
    TRIBOLOGY TRANSACTIONS, 1996, 39 (01): : 93 - 98
  • [7] Influence of start-up modes on the noise characteristics of mixed-flow pump during start-up process
    Zhu, Guojun
    Xuan, Yifan
    Feng, Jianjun
    Tang, Zhenbo
    Li, Yunzhe
    Wang, Like
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2024, 214
  • [8] The effect of pipeline length on the transient process of an electric pump during start-up of a hybrid rocket motor
    Tian, Hui
    Gu, Xiaoming
    Wang, Jiangning
    Tan, Guang
    Liang, Tong
    Cai, Guobiao
    ACTA ASTRONAUTICA, 2023, 212 : 1 - 13
  • [9] Transient Internal Flow Characteristics of Centrifugal Pump During Rapid Start-Up
    Dong, Wei
    Fan, Xugang
    Dong, Yan
    He, Fan
    IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY-TRANSACTIONS OF MECHANICAL ENGINEERING, 2024, 48 (03) : 821 - 831
  • [10] Optimization of Pump Start-Up Depth in Drainage Pumping Station Based on SWMM and PSO
    Wang, Hao
    Lei, Xiaohui
    Khu, Soon-Thiam
    Song, Lixiang
    WATER, 2019, 11 (05)