Evaluation of biventricular function by cadmium-zinc-telluride SPECT gated tomographic radionuclide angiography: Comparison to conventional SPECT

被引:0
|
作者
Chen, Yue [1 ]
Pang, Zekun [1 ]
Wang, Jiao [1 ]
Yang, Xuewen [1 ]
Li, Jianming [1 ]
机构
[1] TEDA Int Cardiovasc Hosp, Dept Nucl Med, Tianjin, Peoples R China
关键词
biventricular function; cadmium-zinc-telluride; CZT; equilibrium radionuclide ventriculography; ERNV; repeatability; single-photon emission tomography; SPECT; BLOOD-POOL SPECT; RIGHT-VENTRICULAR VOLUMES; EJECTION FRACTION; MYOCARDIAL-PERFUSION; VALUES; CAMERA;
D O I
10.1097/MD.0000000000039821
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We compared and analyzed the consistency and repeatability of left and right ventricular ((LV/RV) functions obtained by gated-equilibrium radionuclide ventriculography (ERNV) with cadmium-zinc-telluride single-photon emission computed tomography (CZT-SPECT) and conventional SPECT (C-SPECT) with sodium iodide crystal detectors. Seventy-seven patients were included in the retrospective study. Both C-SPECT and CZT-SPECT imaging were performed on the same day. Correlations and differences in LV/RV ejection fraction (LVEF and RVEF), peak ejection rate (PER), and peak filling rate (PFR) were compared between the 2 models. Cardiac magnetic resonance (CMR) was partially used as the gold standard, and ultrasound results were included for comparative analysis. Interobserver reproducibility of each parameter obtained by the 2 cameras was compared. Between the 2 cameras, there were no significant difference in LVEF, LVPER, LVPFR, and RVPER (P > .05) and there were in RVEF and RVPFR (P < .05 or .001). The correlations (R value) were 0.831 (LVEF, excellent), 0.619 (RVEF, good), 0.672 (LVPER, good), 0.700 (LVPFR, good), 0.463 (RVPER, normal), and 0.253 (RVPFR, poor). There were no significant difference between CMR and CZT-SPECT in LVEF (P > .05) while there were between CMR and both C-SPECT and ultrasound (P < .05). The correlations were all good (R = 0.660, 0.658, and 0.695). There were no significant difference between CMR and both C-SPECT and CZT-SPET in RVEF (P > .05) and the correlations were good (R = 0.771 and 0.745). For repeatability, the intraclass correlation coefficient of RVPFR by C-SPECT was good (intraclass correlation coefficient = 0.698) and excellent for the rest of the groups (0.823-0.989). The repeatability of LVEF and RVEF was better for CZT-SPECT than for C-SPECT. The repeatability of PER was better for both cameras than PFR. CZT-SPECT tomographic ERNV correlated well with C-SPECT planar ERNV in evaluation of biventricular systolic function and LV diastolic function. Compared with the "gold standard" CMR, both models had good correlation in measuring LV/RVEF. CZT-SPECT had better inter-group reproducibility than C-SPECT. The accuracy of RV diastolic function need further study. CZT-SPECT tomographic ERNV will play an important and unique role in the clinical application of accurate evaluation of biventricular function in the future.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Comparison of Myocardial Perfusion SPECT between Cadmium-Zinc-Telluride Cardiac Camera and Conventional Anger Camera: Influence of the hepatic activity
    Uchida, K.
    Yokoyama, T.
    Takahashi, M.
    Tanaka, K.
    Hida, S.
    Yoshimura, M.
    Koizumi, K.
    Chikamori, T.
    Yamashina, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S358 - S359
  • [22] Quantification of myocardial blood flow with cadmium-zinc-telluride SPECT: Is it worth the effort?
    Hyafil, Fabien
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2023, 104 (7-8) : 309 - 310
  • [23] Left ventricular ejection fraction with gated myocardial perfusion SPECT: a comparison between a conventional scintillation detector gamma camera and cadmium-zinc-telluride detector camera
    Davidsson, A.
    Olsson, E.
    Engvall, J.
    Holmberg, B.
    Gustafsson, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S612 - S612
  • [24] Ventricular peak emptying and filling rates measured by gated tomographic radionuclide angiography using a cadmium–zinc–telluride SPECT camera in chemotherapy-naïve cancer patients
    Naja Liv Hansen
    Christian Haarmark
    Bo Zerahn
    Journal of Nuclear Cardiology, 2020, 27 : 1193 - 1201
  • [25] First Experience DaTSCAN Imaging Using Cadmium-Zinc-Telluride Gamma Camera SPECT
    Farid, Karim
    Queneau, Mathieu
    Guernou, Mohamed
    Lussato, David
    Poullias, Xavier
    Petras, Slavomir
    Caillat-Vigneron, Nadine
    Songy, Bernard
    CLINICAL NUCLEAR MEDICINE, 2012, 37 (08) : E211 - E212
  • [26] Cadmium-zinc-telluride gamma camera allow quarter-dose MPI SPECT
    Nkoulou, Rene
    Kueest, Silke
    Ghadri, Jelena
    Pazhenkottil, Aju
    Husmann, Lars
    Wolfrum, Mathias
    Herzog, Bernhard
    Goetti, Robert
    Fiechter, Michael
    Kaufmann, Philipp
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [27] Gated SPECT radionuclide angiography (SPECT RNA) for the assessment of inter and intra ventricular mechanical synchrony: Applicability to biventricular stimulation
    Daou, D
    Sebag, C
    Coaguila, C
    Vilain, D
    Milliez, P
    Slama, M
    Leenhardt, A
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S316 - S316
  • [28] Cadmium-zinc-telluride gamma camera allow quarter-dose MPI SPECT
    Nkoulou, R.
    Kueest, S. M.
    Ghadri, J. R.
    Pazhenkottil, A. P.
    Husmann, L.
    Wolfrum, M.
    Herzog, B. A.
    Goetti, R. P.
    Fiechter, M.
    Kaufmann, P. A.
    EUROPEAN HEART JOURNAL, 2011, 32 : 47 - 47
  • [29] Comparison of Myocardial Perfusion Imaging Using Thallium-201 Between a New Cadmium-Zinc-Telluride Cardiac Camera and a Conventional SPECT Camera
    Songy, Bernard
    Lussato, David
    Guernou, Mohamed
    Queneau, Mathieu
    Geronazzo, Ricardo
    CLINICAL NUCLEAR MEDICINE, 2011, 36 (09) : 776 - 780
  • [30] Pre-chemotherapy values for left and right ventricular volumes and ejection fraction by gated tomographic radionuclide angiography using a cadmium-zinc-telluride detector gamma camera
    Christian Haarmark
    Christine Haase
    Maria Maj Jensen
    Bo Zerahn
    Journal of Nuclear Cardiology, 2016, 23 : 87 - 97