OBJECTIVE METHOD OF MEASURING RESOLUTION OF IMAGE INTENSIFIER TUBES

被引:2
|
作者
Chrzanowski, Krzysztof [1 ,2 ]
Stafiej, Boleslaw [2 ]
机构
[1] Mil Univ Technol, Inst Optoelect, 2 Kaliskiego Str, PL-00908 Warsaw, Poland
[2] INFRAMET, Bugaj 29a, PL-05082 Stare Babice, Poland
关键词
image intensifier; IIT; resolution measurement; subjective resolution; objective resolution;
D O I
10.24425/mms.2024.149704
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Image intensifier tubes (IITs) are the most important modules of night vision devices used in huge numbers by military forces worldwide. Resolution is the most important parameter of IITs that presents information about ability of these devices to produce output images preserving information about details of the observed scenery. Despite its importance, it is still a common practice to measure resolution subjectively, by an observer looking at image of a resolution target created by a tested IIT. A series of attempts have been carried out to develop objective methods for accurate resolution measurement of IITs but with limited success. Accuracy of these methods varies depending on the tested IIT. This paper presents detailed analysis of proposed methods for objective resolution measurement. This analysis has shown that significant variability of accuracy of these methods is caused by one main drawback: the methods do not take into account influence of the spatial noise effect on human perception of image of the resolution target. Thus, an improved method taking into account spatial noise and its impact on target detection has been proposed. The method has been validated through experimental verification that shows accuracy improvements compared to other objective methods. This new approach improves accuracy of measurement of resolution of IITs to a level that can be accepted at professional test stations. In this way, this new method has potential to replace the standard subjective method to measure resolution of IITs and fix the biggest flaw of the standard test stations: measurement subjectivity.
引用
收藏
页码:339 / 352
页数:14
相关论文
共 50 条
  • [1] Subjective measurement of resolution of image intensifier tubes
    Chrzanowski, Krzysztof
    OPTICA APPLICATA, 2024, 54 (02) : 149 - 162
  • [2] RESOLUTION LIMITATIONS OF ELECTROMAGNETICALLY FOCUSED IMAGE-INTENSIFIER TUBES
    CSORBA, IP
    RCA REVIEW, 1969, 30 (01): : 36 - &
  • [3] HIGH-RESOLUTION LUMINESCENT SCREENS FOR IMAGE INTENSIFIER TUBES
    DUCHENOIS, V
    FOUASSIER, M
    PIAGET, C
    ADVANCES IN IMAGING AND ELECTRON PHYSICS, 1985, 64 : 365 - 371
  • [4] RESOLUTION OF FIBEROPTIC FACEPLATE IMAGE-INTENSIFIER TUBES AS A FUNCTION OF MAGNIFICATION
    DOLON, PJ
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 1974, ED21 (06) : 376 - 377
  • [5] DETECTIVITY OF INTENSIFIER IMAGE TUBES
    NUDELMAN, S
    APPLIED OPTICS, 1966, 5 (12): : 1925 - &
  • [6] Objective Evaluation of the Resolution of Image Intensifier Based on Stripe Variation Features
    Wang Luzi
    Qian Yunsheng
    Sun Mohan
    Kong Xiangyu
    ACTA PHOTONICA SINICA, 2022, 51 (03)
  • [7] IMAGE INTENSIFIER TUBES WITH INTAGLIATED SCREENS
    FOUASSIER, M
    DUCHENOIS, V
    DIETZ, J
    GUILLEMET, E
    LEMONIER, M
    ADVANCES IN ELECTRONICS AND ELECTRON PHYSICS, 1988, 74 : 315 - 322
  • [8] NEW GATED IMAGE INTENSIFIER TUBES
    SCHMIDT, L
    WEBER, S
    OPTIK, 1977, 49 (01): : 93 - 104
  • [9] Third Generation Image Intensifier Tubes.
    Fouassier, Michele
    Piaget, Claude
    Richard, Jean-Claude
    Roaux, Eric
    Acta electronica Paris, 1987, 27 (3-4): : 159 - 163
  • [10] PERFORMANCE EVALUATION OF IMAGE-INTENSIFIER TUBES
    LEE, D
    SOURKES, AM
    HOLLOWAY, AF
    REED, MH
    RADIOLOGY, 1981, 138 (02) : 455 - 459