Electromagnets Under the Table: An Unobtrusive Magnetic Navigation System for Microsurgery

被引:1
|
作者
Schonewille, Adam [1 ]
He, Changyan [1 ,2 ,3 ]
Forbrigger, Cameron [1 ,4 ]
Wu, Nancy [1 ,2 ]
Drake, James [2 ]
Looi, Thomas [2 ]
Diller, Eric [1 ,5 ,6 ]
机构
[1] Univ Toronto, Dept Mech & Ind Engn, Toronto, ON M5S 3G8, Canada
[2] SickKids Hosp, PCIGITI Ctr, Toronto, ON M5G 1E8, Canada
[3] Univ Newcastle, Dept Med Engn, Newcastle, NSW 2308, Australia
[4] Swiss Fed Inst Technol, Dept Hlth Sci & Technol, CH-8092 Zurich, Switzerland
[5] Univ Toronto, Robot Inst, Toronto, ON M5S 3G8, Canada
[6] Univ Toronto, Inst Biomed Engn, Toronto, ON M5S 3G8, Canada
来源
IEEE TRANSACTIONS ON MEDICAL ROBOTICS AND BIONICS | 2024年 / 6卷 / 03期
基金
加拿大健康研究院;
关键词
Magnetic fields; Actuators; Electromagnets; Magnets; Coils; Navigation; Magnetic cores; Electromagnetic system; magnetic actuation; microrobotics; workspace accessibility; medical application; FORCEPS; DESIGN;
D O I
10.1109/TMRB.2024.3421249
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Miniature magnetic tools have the potential to enable minimally invasive surgical techniques to be applied to space-restricted surgical procedures in areas such as neurosurgery. However, typical magnetic navigation systems, which create the magnetic fields to drive such tools, either cannot generate large enough fields, or surround the patient in a way that obstructs surgeon access to the patient. This paper introduces the design of a magnetic navigation system with eight electromagnets arranged completely under the operating table, to endow the system with maximal workspace accessibility, which allows the patient to lie down on the top surface of the system without any constraints. The found geometric layout of the electromagnets maximizes the field strength and uniformity over a reasonable neurosurgical operating volume. The system can generate non-uniform magnetic fields up to 38 mT along the x and y axes and 47 mT along the z axis at a working distance of 120 mm away from the actuation system workbench, deep enough to deploy magnetic microsurgical tools in the brain. The forces which can be exerted on millimeter-scale magnets used in prototype neurosurgical tools are validated experimentally. Due to its large workspace, this system could be used to control milli-robots in a variety of surgical applications.
引用
收藏
页码:980 / 991
页数:12
相关论文
共 50 条
  • [21] Stereotaxis Niobe® magnetic navigation system for endocardial catheter ablation and gastrointestinal capsule endoscopy
    Carpi, Federico
    Pappone, Carlo
    EXPERT REVIEW OF MEDICAL DEVICES, 2009, 6 (05) : 487 - 498
  • [22] Odometry Correction with Localization Based on Landmarkless Magnetic Map for Navigation System of Indoor Mobile Robot
    Rahok, Sam Ann
    Koichi, Ozaki
    PROCEEDINGS OF THE FOURTH INTERNATIONAL CONFERENCE ON AUTONOMOUS ROBOTS AND AGENTS, 2009, : 168 - 173
  • [23] Electromagnetic Control System for Capsule Navigation: Novel Concept for Magnetic Capsule Maneuvering and Preliminary Study
    Lucarini, Gioia
    Mura, Marco
    Ciuti, Gastone
    Rizzo, Rocco
    Menciassi, Arianna
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2015, 35 (04) : 428 - 436
  • [24] Electromagnetic Control System for Capsule Navigation: Novel Concept for Magnetic Capsule Maneuvering and Preliminary Study
    Gioia Lucarini
    Marco Mura
    Gastone Ciuti
    Rocco Rizzo
    Arianna Menciassi
    Journal of Medical and Biological Engineering, 2015, 35 : 428 - 436
  • [25] Efficient Onboard Energy Storage System Sizing for All-Electric Ship Microgrids Via Optimized Navigation Routing Under Onshore Uncertainties
    Zhao, Tianyang
    Qiu, Jiayu
    Wen, Shuli
    Zhu, Miao
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2022, 58 (02) : 1664 - 1674
  • [26] Tumor ablation therapy of liver cancers with an open magnetic resonance imaging-based navigation system
    Maeda, Takashi
    Hong, Jaesung
    Konishi, Kozo
    Nakatsuji, Takanori
    Yasunaga, Takefumi
    Yamashita, Yo-ichi
    Taketomi, Akinobu
    Kotoh, Kazuhiro
    Enjoji, Munechika
    Nakashima, Hideaki
    Tanoue, Kazuo
    Maehara, Yoshihiko
    Hashizume, Makoto
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2009, 23 (05): : 1048 - 1053
  • [27] Tumor ablation therapy of liver cancers with an open magnetic resonance imaging-based navigation system
    Takashi Maeda
    Jaesung Hong
    Kozo Konishi
    Takanori Nakatsuji
    Takefumi Yasunaga
    Yo-ichi Yamashita
    Akinobu Taketomi
    Kazuhiro Kotoh
    Munechika Enjoji
    Hideaki Nakashima
    Kazuo Tanoue
    Yoshihiko Maehara
    Makoto Hashizume
    Surgical Endoscopy, 2009, 23
  • [28] Optimal Motion Control of a Capsule Endoscope in the Stomach Utilizing a Magnetic Navigation System with Dual Permanent Magnets
    Bae, Suhong
    Kwon, Junhyoung
    Kim, Jongyul
    Jang, Gunhee
    MICROMACHINES, 2024, 15 (08)
  • [29] Table-top nuclear magnetic resonance system for high-pressure studies with in situ laser heating
    Meier, Thomas
    Dwivedi, Anand Prashant
    Khandarkhaeva, Saiana
    Fedotenko, Timofey
    Dubrovinskaia, Natalia
    Dubrovinsky, Leonid
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2019, 90 (12)
  • [30] Multipurpose television system of operational aid to navigation in coastal zone under low-visibility conditions
    Kaloshin, G. A.
    Skolotnev, I. A.
    Petukhov, A. A.
    24TH INTERNATIONAL SYMPOSIUM ON ATMOSPHERIC AND OCEAN OPTICS: ATMOSPHERIC PHYSICS, 2018, 10833