A Visual Distance-Based Capillary Immunoassay Using Biomimetic Polymer Nanoparticles for Highly Sensitive and Specific C-Reactive Protein Quantification

被引:0
|
作者
Huang, Ruodong [1 ]
Liu, Zhenbo [1 ]
Jiang, Xinlin [1 ]
Huang, Junqi [1 ]
Zhou, Ping [1 ]
Mou, Zongxia [1 ]
Ma, Dong [1 ]
Cui, Xin [1 ]
机构
[1] Jinan Univ, Guangdong Higher Educ Inst, Dept Biomed Engn, Key Lab Biomat, Guangzhou 510632, Peoples R China
基金
中国国家自然科学基金;
关键词
distance-based immunoassay; C-reactive protein; biomimetic nanoparticles; specificity; SURFACE; CHIP;
D O I
10.3390/ijms25189771
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The low-cost daily monitoring of C-reactive protein (CRP) levels is crucial for screening acute inflammation or infections as well as managing chronic inflammatory diseases. In this study, we synthesized novel 2-Methacryloyloxy ethyl phosphorylcholine (MPC)-based biomimetic nanoparticles with a large surface area to develop a visual CRP-quantification assay using affordable glass capillaries. The PMPC nanoparticles, synthesized via reflux precipitation polymerization, demonstrated multivalent binding capabilities, enabling rapid and specific CRP capture. In the presence of CRP, PMPC nanoparticles formed sandwich structures with magnetic nanoparticles functionalized with CRP antibodies, thereby enhancing detection sensitivity and specificity. These sandwich complexes were magnetically accumulated into visible and quantifiable stacks within the glass capillaries, allowing for the rapid, sensitive, and specific quantification of CRP concentrations with a detection limit of 57.5 pg/mL and a range spanning from 0 to 5000 ng/mL. The proposed visual distance-based capillary biosensor shows great potential in routine clinical diagnosis as well as point-of-care testing (POCT) in resource-limited settings.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Effects of low-dose aspirin on serum C-reactive protein and thromboxane B2 concentrations:: A placebo-controlled study using a highly sensitive C-reactive protein assay
    Feldman, M
    Jialal, I
    Devaraj, S
    Cryer, B
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (08) : 2036 - 2041
  • [42] Demonstration of a direct capture immunoaffinity separation for C-reactive protein using a capillary-based microfluidic device
    Peoples, Michael C.
    Phillips, Terry M.
    Karnes, H. Thomas
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 48 (02) : 376 - 382
  • [43] Development of a Highly Sensitive Latex Reagent Directed against C-Reactive Protein (CRP) Using Epitope Analysis with Monoclonal Antibodies
    Komoriya, Tomoe
    Kikuchi, Maho
    Terashima, Yutaka
    Okamoto, Mayumi
    Ogawa, Masahiro
    Moriyama, Mituhiko
    Kohno, Hideki
    BIOSCIENCE BIOTECHNOLOGY AND BIOCHEMISTRY, 2010, 74 (02) : 292 - 297
  • [44] A highly sensitive capillary electrophoresis immunoassay strategy based on dual-labeled gold nanoparticles enhancing chemiluminescence for the detection of prostate-specific antigen
    Li, Shuting
    Shi, Min
    Zhao, Jingjin
    Zhang, Liangliang
    Huang, Yong
    Zhao, Shulin
    ELECTROPHORESIS, 2017, 38 (13-14) : 1780 - 1787
  • [45] The improved sensitive detection of C-reactive protein based on the chemiluminescence immunoassay by employing monodispersed PAA-Au/Fe3O4 nanoparticles and zwitterionic glycerophosphoryl choline
    Xing, Yan
    Gao, Qin
    Zhang, Yanmin
    Ma, Le
    Loh, Kang Yong
    Peng, Mingli
    Chen, Chao
    Cui, Yali
    JOURNAL OF MATERIALS CHEMISTRY B, 2017, 5 (21) : 3919 - 3926
  • [46] A simple aptamer-based colorimetric assay for rapid detection of C-reactive protein using gold nanoparticles
    Antonio, Maria
    Ferreira, Rita
    Vitorino, Rui
    Daniel-da-Silva, Ana L.
    TALANTA, 2020, 214
  • [47] A facile one-step gold nanoparticles enhancement based on sequential patterned lateral flow immunoassay device for C-reactive protein detection
    Panraksa, Yosita
    Apilux, Amara
    Jampasa, Sakda
    Puthong, Songchan
    Henry, Charles S.
    Rengpipat, Sirirat
    Chailapakul, Orawon
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 329
  • [48] Preparation of a portable point-of-care in vitro diagnostic system, for quantification of canine C-reactive protein, based on a magnetic two-site immunoassay
    Filiz Ibraimi
    Björn Ekberg
    Dario Kriz
    Gertrud Danielsson
    Leif Bülow
    Analytical and Bioanalytical Chemistry, 2013, 405 : 6001 - 6007
  • [49] Preparation of a portable point-of-care in vitro diagnostic system, for quantification of canine C-reactive protein, based on a magnetic two-site immunoassay
    Ibraimi, Filiz
    Ekberg, Bjorn
    Kriz, Dario
    Danielsson, Gertrud
    Bulow, Leif
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (18) : 6001 - 6007
  • [50] Highly Sensitive and Fast Detection of C-Reactive Protein and Troponin Biomarkers Using Liquid-gated Single Silicon Nanowire Biosensors
    Kutovyi, Yurii
    Li Jie
    Zadorozhnyi, Ihor
    Hlukhova, Hanna
    Boichuk, Nazarii
    Yehorov, Dmytro
    Menger, Marcus
    Vitusevich, Svetlana
    MRS ADVANCES, 2020, 5 (16) : 835 - 846