A Visual Distance-Based Capillary Immunoassay Using Biomimetic Polymer Nanoparticles for Highly Sensitive and Specific C-Reactive Protein Quantification

被引:0
|
作者
Huang, Ruodong [1 ]
Liu, Zhenbo [1 ]
Jiang, Xinlin [1 ]
Huang, Junqi [1 ]
Zhou, Ping [1 ]
Mou, Zongxia [1 ]
Ma, Dong [1 ]
Cui, Xin [1 ]
机构
[1] Jinan Univ, Guangdong Higher Educ Inst, Dept Biomed Engn, Key Lab Biomat, Guangzhou 510632, Peoples R China
基金
中国国家自然科学基金;
关键词
distance-based immunoassay; C-reactive protein; biomimetic nanoparticles; specificity; SURFACE; CHIP;
D O I
10.3390/ijms25189771
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The low-cost daily monitoring of C-reactive protein (CRP) levels is crucial for screening acute inflammation or infections as well as managing chronic inflammatory diseases. In this study, we synthesized novel 2-Methacryloyloxy ethyl phosphorylcholine (MPC)-based biomimetic nanoparticles with a large surface area to develop a visual CRP-quantification assay using affordable glass capillaries. The PMPC nanoparticles, synthesized via reflux precipitation polymerization, demonstrated multivalent binding capabilities, enabling rapid and specific CRP capture. In the presence of CRP, PMPC nanoparticles formed sandwich structures with magnetic nanoparticles functionalized with CRP antibodies, thereby enhancing detection sensitivity and specificity. These sandwich complexes were magnetically accumulated into visible and quantifiable stacks within the glass capillaries, allowing for the rapid, sensitive, and specific quantification of CRP concentrations with a detection limit of 57.5 pg/mL and a range spanning from 0 to 5000 ng/mL. The proposed visual distance-based capillary biosensor shows great potential in routine clinical diagnosis as well as point-of-care testing (POCT) in resource-limited settings.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Distance-based lateral flow immunoassay for quantitative detection of C-reactive protein in cardiovascular risk assessment
    Ruantip, Sirowan
    Pimpitak, Umaporn
    Puthong, Songchan
    Rengpipat, Sirirat
    Yakoh, Abdulhadee
    Sain, Mohini M.
    Komolpis, Kittinan
    Chaiyo, Sudkate
    SENSORS AND ACTUATORS B-CHEMICAL, 2025, 434
  • [2] Sensitive and rapid quantification of C-reactive protein using quantum dot-labeled microplate immunoassay
    Luo, Yang
    Zhang, Bo
    Chen, Ming
    Jiang, Tianlun
    Zhou, Daiyang
    Huang, Junfu
    Fu, Weiling
    JOURNAL OF TRANSLATIONAL MEDICINE, 2012, 10
  • [3] Sensitive and rapid quantification of C-reactive protein using quantum dot-labeled microplate immunoassay
    Yang Luo
    Bo Zhang
    Ming Chen
    Tianlun Jiang
    Daiyang Zhou
    Junfu Huang
    Weiling Fu
    Journal of Translational Medicine, 10
  • [4] Sensitive and specific automated chemiluminescent enzyme immunoassay for C-reactive protein.
    Panosian-Sahakian, N
    Whitters, E
    Lei, JD
    Laroya, R
    Unver, E
    El Shami, AS
    CLINICAL CHEMISTRY, 1998, 44 : A26 - A27
  • [5] Graphene-based rapid and highly-sensitive immunoassay for C-reactive protein using a smartphone-based colorimetric reader
    Vashist, Sandeep Kumar
    Schneider, E. Marion
    Zengerle, Roland
    von Stetten, Felix
    Luong, John H. T.
    BIOSENSORS & BIOELECTRONICS, 2015, 66 : 169 - 176
  • [6] Detection of c-reactive protein based on immunoassay using antibody-conjugated magnetic nanoparticles
    Tsai, H. Y.
    Hsu, C. F.
    Chiu, I. W.
    Fuh, C. Bor
    ANALYTICAL CHEMISTRY, 2007, 79 (21) : 8416 - 8419
  • [7] Capillary-based chemiluminescence immunoassay for C-reactive protein with portable imaging device
    Shen, Haiying
    Khan, Rizwanullah
    Wang, Xiaoqian
    Li, Zulan
    Qu, Feng
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (27) : 7177 - 7183
  • [8] Capillary-based chemiluminescence immunoassay for C-reactive protein with portable imaging device
    Haiying Shen
    Rizwanullah Khan
    Xiaoqian Wang
    Zulan Li
    Feng Qu
    Analytical and Bioanalytical Chemistry, 2018, 410 : 7177 - 7183
  • [9] Analytical performance of a highly sensitive C-reactive protein-based immunoassay and the effects of laboratory variables on levels of protein in blood
    Aziz, N
    Fahey, JL
    Detels, R
    Butch, AW
    CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 2003, 10 (04) : 652 - 657
  • [10] Detection of c-reactive protein based on a magnetic immunoassay by using functional magnetic and fluorescent nanoparticles in microplates
    Yang, S. F.
    Gao, B. Z.
    Tsai, H. Y.
    Fuh, C. Bor
    ANALYST, 2014, 139 (21) : 5576 - 5581