Quantification of Treatment Plan Deliverability in Breast Volumetric-modulated Arc Therapy With Agility Multi-leaf Collimator

被引:1
作者
Oh, Do Hoon [1 ]
Choi, Jin Hwa [2 ]
Ryu, Hyejo [1 ]
Chun, Minsoo [1 ,3 ,4 ]
机构
[1] Chung Ang Univ, Gwang Myeong Hosp, Dept Radiat Oncol, Seoul 14353, Gyeonggi Do, South Korea
[2] Chung Ang Univ, Coll Med, Dept Radiat Oncol, Seoul, South Korea
[3] Chung Ang Univ, Clin Res Ctr, Gwang Myeong Hosp, Seoul, Gyeonggi Do, South Korea
[4] Seoul Natl Univ, Med Res Ctr, Inst Radiat Med, Seoul, South Korea
来源
IN VIVO | 2024年 / 38卷 / 05期
关键词
Breast radiotherapy; volumetric modulated arc therapy; plan complexity; plan deliverability; multi-leaf collimator; QUALITY-ASSURANCE; RADIATION-THERAPY; APERTURE COMPLEXITY; IMRT; DELIVERY; IMPLEMENTATION; METRICS;
D O I
10.21873/invivo.13690
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background/Aim: The aim was to assess the complexity of breast volumetric-modulated arc therapy (VMAT) plans using various indices and to evaluate their performance through gamma analysis in predicting plan deliverability. Materials and Methods: A total of 285 VMAT plans for 260 patients were created using the VersaHDTM linear accelerator with a Monaco treatment planning system. Corresponding verification plans were generated using the ArcCHECK (R) detector, and gamma analysis was conducted employing various criteria. Twenty-eight plan complexity metrics were computed, and Pearson's correlation coefficients were determined between the gamma passing rate (GPR) and these metrics. Results: The average GPR values for all plans were 97.7%, 89.9%, and 78.0% for the 2 mm/2%, 1 mm/2%, and 1 mm/1% criteria, respectively. While most complexity metrics exhibited weak correlations with GPRs under the 2 mm/2% criterion, leaf converted area metric (CAM), and edge area metric (EAM) demonstrated the most robust performance, with Pearson's correlation coefficients of 0.57, 0.50, -0.70, and -0.56, respectively. Conclusion: Metrics related to beam aperture size and irregularity, such as LSV, PA, CAM and EAM, proved to be reasonable predictors of plan deliverability in breast VMAT.
引用
收藏
页码:2254 / 2260
页数:7
相关论文
共 41 条
  • [1] Implementation of phantom-less IMRT delivery verification using Varian DynaLog files and R/V output
    Agnew, C. E.
    King, R. B.
    Hounsell, A. R.
    McGarry, C. K.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (21) : 6761 - 6777
  • [2] Intensity modulated radiotherapy treatment planning by use of a barrier-penalty multiplier method
    Alber, M.
    Reemtsen, R.
    [J]. OPTIMIZATION METHODS & SOFTWARE, 2007, 22 (03) : 391 - 411
  • [3] AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams
    Almond, PR
    Biggs, PJ
    Coursey, BM
    Hanson, WF
    Huq, MS
    Nath, R
    Rogers, DWO
    [J]. MEDICAL PHYSICS, 1999, 26 (09) : 1847 - 1870
  • [4] Boyer A., 2001, Basic Applications of multileaf collimators
  • [5] A machine learning approach to the accurate prediction of multi-leaf collimator positional errors
    Carlson, Joel N. K.
    Park, Jong Min
    Park, So-Yeon
    Park, Jong In
    Choi, Yunseok
    Ye, Sung-Joon
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (06) : 2514 - 2531
  • [6] A tool for patient-specific prediction of delivery discrepancies in machine parameters using trajectory log files
    Chuang, Kai-Cheng
    Giles, William
    Adamson, Justus
    [J]. MEDICAL PHYSICS, 2021, 48 (03) : 978 - 990
  • [7] Quantifications of Intensity-Modulated Radiation Therapy Plan Complexities in Magnetic Resonance Image Guided Radiotherapy Systems
    Chun, Minsoo
    Kwon, Ohyun
    Park, Jong Min
    Kim, Jung -in
    [J]. JOURNAL OF RADIATION PROTECTION AND RESEARCH, 2021, 46 (02): : 48 - 57
  • [8] Critical appraisal of the role of volumetric modulated arc therapy in the radiation therapy management of breast cancer
    Cozzi, Luca
    Lohr, Frank
    Fogliata, Antonella
    Franceschini, Davide
    De Rose, Fiorenza
    Filippi, A. R.
    Guidi, Gabriele
    Vanoni, Valentina
    Scorsetti, Marta
    [J]. RADIATION ONCOLOGY, 2017, 12
  • [9] Treatment plan complexity metrics for predicting IMRT pre-treatment quality assurance results
    Crowe, S. B.
    Kairn, T.
    Kenny, J.
    Knight, R. T.
    Hill, B.
    Langton, C. M.
    Trapp, J. V.
    [J]. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2014, 37 (03) : 475 - 482
  • [10] Quantification of beam complexity in intensity-modulated radiation therapy treatment plans
    Du, Weiliang
    Cho, Sang Hyun
    Zhang, Xiaodong
    Hoffman, Karen E.
    Kudchadker, Rajat J.
    [J]. MEDICAL PHYSICS, 2014, 41 (02)