Determination of Glucose by an Optical Biosensor Composed of a Molecularly Imprinted Polymer, Glucose Oxidase, and Bromothymol Blue

被引:0
|
作者
Hashemi-Moghaddam, Hamid [1 ]
Salamat, Qamar [2 ]
Soylak, Mustafa [2 ,3 ,4 ]
机构
[1] Islamic Azad Univ, Dept Chem, Damghan Branch, Damghan, Iran
[2] Erciyes Univ, Fac Sci, Dept Chem, TR-38039 Kayseri, Turkiye
[3] Erciyes Univ, Technol Res & Applicat Ctr ERU TAUM, Kayseri, Turkiye
[4] Turkish Acad Sci TUBA, Ankara, Turkiye
关键词
Biosensor; glucose determination; glucose oxidase; molecularly imprinted polymer (MIP); saliva analysis; smartphone analysis; NONENZYMATIC ELECTROCHEMICAL GLUCOSE; SOLID-PHASE EXTRACTION; CARBON DOTS; SAMPLES; CU;
D O I
10.1080/00032719.2024.2384059
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An optical biosensor was developed as a novel adsorbent to isolate glucose from saliva. A straightforward procedure was used to create the glucose-imprinted polymer coating on the surface of zeolitic imidazolate framework (ZIF-8) nanoparticles which served as the adsorbent. Glucose oxidase was immobilized. Fourier-transform infrared spectroscopy (FT-IR), X-ray diffraction (XRD), scanning electron microscopy (SEM), and Brunauer-Emmett-Teller (BET) analysis were used to characterize the novel adsorbent. The ZIF-8 nanoparticles were synthesized and coated with the MIP via precipitation polymerization on the surface of ZIF-8 nanoparticles with glucose acting as a template. To determine glucose, glucose oxidase catalyzed the conversion of adsorbed analyte on the polymer surface to gluconic acid. The resulting color change due to bromothymol blue was characterized using a colorimetric-based smartphone using the RGB profile. Key parameters such as pH, adsorbent mass, adsorption time, and indicator concentration were optimized and under these conditions this biosensor showed few interferences and good sensitivity with a 20 s response time. A linear range from 300 to 500 mg dL-1 was demonstrated by an exponentially growing calibration curve when saliva with pixel slopes (R + G + B) were used for calibration. This biosensor provides a low-cost and fast approach for glucose determination in biological samples.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] An Amperometric Biosensor for Glucose Based on Electrodeposited Redox Polymer/Glucose Oxidase Film on a Gold Electrode
    Junjie Fei
    Yunhua Wu
    Xiaobo Ji
    Jing Wang
    Shengshui Hu
    Zhiqiang Gao
    Analytical Sciences, 2003, 19 : 1259 - 1263
  • [32] GLUCOSE BIOSENSOR BASED ON THE INCORPORATION OF MELDOLA BLUE AND GLUCOSE-OXIDASE WITHIN CARBON-PASTE
    KULYS, J
    HANSEN, HE
    BUCHRASMUSSEN, T
    WANG, J
    OZSOZ, M
    ANALYTICA CHIMICA ACTA, 1994, 288 (03) : 193 - 196
  • [33] Amperometric Glucose Biosensor Based on Titanium Electrode Modified with Prussian Blue Layer and Immobilized Glucose Oxidase
    Valiuniene, A.
    Virbickas, P.
    Rekertaite, A.
    Ramanavicius, A.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2017, 164 (14) : B781 - B784
  • [34] Fluorescent molecularly imprinted polymer film binds glucose with a concomitant changes in fluorescence
    Manju, S.
    Hari, P. R.
    Sreenivasan, K.
    BIOSENSORS & BIOELECTRONICS, 2010, 26 (02): : 894 - 897
  • [35] A Highly Sensitive Molecularly Imprinted Polymer (MIP)-Coated Microwave Glucose Sensor
    Omidvar, Amir Hossein
    Shahri, Atena Amanati
    Caniato Serrano, Ariana Lacorte
    Gruber, Jonas
    Rehder, Gustavo Pamplona
    SENSORS, 2022, 22 (22)
  • [36] Thermal Detection of Glucose in Urine Using a Molecularly Imprinted Polymer as a Recognition Element
    Caldara, Manlio
    Lowdon, Joseph W.
    Rogosic, Renato
    Arreguin-Campos, Rocio
    Jimenez-Monroy, Kathia L.
    Heidt, Benjamin
    Tschulik, Kristina
    Cleij, Thomas J.
    Dilien, Hanne
    Eersels, Kasper
    van Grinsven, Bart
    ACS SENSORS, 2021, 6 (12) : 4515 - 4525
  • [37] A glucose sensor using gate effect of molecularly imprinted polymer grafted on electrode
    Yoshimi, Yasuo
    Narimatsu, Akisato
    Sakai, Kiyotaka
    JOURNAL OF BIOSCIENCE AND BIOENGINEERING, 2009, 108 : S31 - S31
  • [38] Potentiometric Glucose Determination in Human Serum Samples with Glucose Oxidase Biosensor Based on Iodide Electrode
    Karakus, E.
    Pekyardimci, S.
    Kilic, E.
    APPLIED BIOCHEMISTRY AND MICROBIOLOGY, 2013, 49 (02) : 194 - 198
  • [39] Potentiometric glucose determination in human serum samples with glucose oxidase biosensor based on iodide electrode
    E. Karakuş
    Ş. Pekyardımcı
    E. Kiliç
    Applied Biochemistry and Microbiology, 2013, 49 : 194 - 198
  • [40] Determination of glucose in human serum based on an onion primary cuticula biosensor immobilized glucose oxidase
    Jia, Wenjuan
    Liu, Wenjuan
    Zhang, Yan
    Cui, Miao
    Shuang, Shaomin
    Dong, Chuan
    Choi, Martin M. F.
    ANALYTICAL METHODS, 2012, 4 (05) : 1432 - 1437