PPG and Bioimpedance-Based Wearable Applications in Heart Rate Monitoring-A Comprehensive Review

被引:6
作者
Lapsa, Didzis [1 ]
Janeliukstis, Rims [1 ]
Metshein, Margus [2 ]
Selavo, Leo [1 ]
机构
[1] Inst Elect & Comp Sci, Dzerbenes St 14, LV-1006 Riga, Latvia
[2] Tallinn Univ Technol, Thomas Johann Seebeck Dept Elect, Ehitajate Tee 5, EE-19086 Tallinn, Estonia
来源
APPLIED SCIENCES-BASEL | 2024年 / 14卷 / 17期
关键词
bioimpedance; photoplethysmography; heart rate; wearable device; monitoring; EMPIRICAL MODE DECOMPOSITION; PULSE WAVE-FORMS; PHOTOPLETHYSMOGRAPHIC SIGNALS; ARTIFACT REDUCTION; MOTION ARTIFACTS; CARDIAC-OUTPUT; IMPEDANCE; HEALTH; SENSOR; TECHNOLOGY;
D O I
10.3390/app14177451
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The monitoring of hemodynamic parameters, such as heart rate and blood pressure, provides valuable indications of overall cardiovascular health. It is preferable that such monitoring is non-invasive and in real time via an affordable, compact and small-scale device for maximum convenience. Numerous literature sources have exploited derivations of these parameters from photoplethysmogram (PPG) and electrical bioimpedance (EBI) signal measurements through the use of calculation algorithms of varying complexity. Compared to electrocardiogram (ECG), these measurement techniques have a merit of well-established practices of designing a wearable device that could conveniently be put on a wrist. The current paper provides a comprehensive review on the use of PPG and EBI measurement techniques in the context of hemodynamic parameter monitoring using a wearable device. A special emphasis is placed on the most basic hemodynamic parameter-heart rate-describing different algorithms of heart rate detection and monitoring. The last section provides an overview of commercially available and in-home wearable device technologies based on PPG and EBI measurements, their design challenges, and future prospects.
引用
收藏
页数:35
相关论文
共 170 条
[1]   Comparative Analysis of the Equivital EQ02 Lifemonitor with Holter Ambulatory ECG Device for Continuous Measurement of ECG, Heart Rate, and Heart Rate Variability: A Validation Study for Precision and Accuracy [J].
Akintola, Abimbola A. ;
van de Pol, Vera ;
Bimmel, Daniel ;
Maan, Arie C. ;
van Heemst, Diana .
FRONTIERS IN PHYSIOLOGY, 2016, 7
[2]   Automatic quality assessment of capacitively-coupled bioimpedance signals for respiratory activity monitoring [J].
Albaba, Adnan ;
Castro, Ivan ;
Borzee, Pascal ;
Buyse, Bertien ;
Testelmans, Dries ;
Varon, Carolina ;
Van Huffel, Sabine ;
Torfs, Tom .
BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2021, 68
[3]  
Alharbi Y., 2021, P 2021 7 INT C BIOS, P1
[4]   Photoplethysmography and its application in clinical physiological measurement [J].
Allen, John .
PHYSIOLOGICAL MEASUREMENT, 2007, 28 (03) :R1-R39
[5]   Graphene Electronic Tattoo Sensors [J].
Ameri, Shideh Kabiri ;
Ho, Rebecca ;
Jang, Hongwoo ;
Tao, Li ;
Wang, Youhua ;
Wang, Liu ;
Schnyer, David M. ;
Akinwande, Deji ;
Lu, Nanshu .
ACS NANO, 2017, 11 (08) :7634-7641
[6]  
Apple, Apple Watch
[7]   Heart rate estimation from photoplethysmography signal for wearable health monitoring devices [J].
Arunkumar, K. R. ;
Bhaskar, M. .
BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2019, 50 :1-9
[8]  
Aura Ring, About us
[9]   Energy-harvesting based on internet of things and big data analytics for smart health monitoring [J].
Babar, Muhammad ;
Rahman, Ataur ;
Arif, Fahim ;
Jeon, Gwanggil .
SUSTAINABLE COMPUTING-INFORMATICS & SYSTEMS, 2018, 20 :155-164
[10]   BIOELECTRIC IMPEDANCE PHASE-ANGLE AND BODY-COMPOSITION [J].
BAUMGARTNER, RN ;
CHUMLEA, WC ;
ROCHE, AF .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1988, 48 (01) :16-23