Effect of thermoelectric subcooling on COP and energy consumption of a propane heat pump

被引:2
作者
Aranguren, P. [1 ,2 ]
Sanchez, D. [3 ]
Haida, M. [4 ]
Smolka, J. [4 ]
Cabello, R. [3 ]
Rodriguez, A. [1 ,2 ]
Astrain, D. [1 ,2 ]
机构
[1] Univ Publ Navarra, Engn Dept, Arrosadia Campus, Pamplona 31006, Spain
[2] Univ Publ Navarra, Inst Smart Cities, Arrosadia Campus, Pamplona 31006, Spain
[3] Jaume I Univ, Dep Mech Engn & Construct, Campus Riu Sec s-n, E-12071 Castellon de La Plana, Spain
[4] Silesian Tech Univ, Dept Thermal Technol, Konarskiego 22, PL-44100 Gliwice, Poland
关键词
Propane; Heat pump; thermoelectric subcooler; COP enhancement; Energy savings; REFRIGERATION CYCLE;
D O I
10.1016/j.applthermaleng.2024.124242
中图分类号
O414.1 [热力学];
学科分类号
摘要
The building sector has an important impact on the environment, being responsible for 30 % of the total greenhouse gas emissions. Knowing that the energy consumption devoted to HVAC systems accounts for 50 % of the total energy consumption of buildings, it is paramount to develop environmentally friendly technologies able to provide green space heating to the building sector. To that purpose, this manuscript presents a computational study on propane vapor compression heat pumps which include thermoelectric subcooling to boost their operation. The combination of these technologies has been proven in the past to be very beneficial for refrigeration systems and this study concludes for the first time that propane heat pumps can highly benefit from thermoelectric subcooling. The widely conducted research includes the following parameters: ambient temperatures from -20 to 15 degrees C, voltage supplies to the thermoelectric modules from 0.5 to 10 VDC, number of thermoelectric subcooling blocks from 1 to 8 and two water inlet temperatures, 40 and 55 degrees C to study their influence on heating capacity, compressor and thermoelectric power consumptions, subcooling degree, propane mass flow, compressor capacity, COP, energy consumption and SCOP of the combined heat pump. The obtained results are very conclusive, COP enhancements up to 12.29 % are achieved when a thermoelectric subcooler with 16 modules is included in a propane heat pump already provided with an internal heat exchanger for an ambient temperature of -20 degrees C and a water inlet temperature of 55 degrees C. Additionally, improvements in Seasonal COP up to 9.98 % are achieved if the above-mentioned technologies integration between a vapor compression heat pump and a thermoelectric subcooler substitutes a conventional propane heat pump with an internal heat exchanger for space heating a single-story two-family house.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Possibilities of Improving COP of Peltier Cells Operating as a Heat Pump
    Rimbala, Jan
    Kyncl, Jan
    2022 22ND INTERNATIONAL SCIENTIFIC CONFERENCE ON ELECTRIC POWER ENGINEERING (EPE), 2022, : 37 - 40
  • [22] Influence of subcooling on performance of direct-expansion solar-assisted heat pump
    Wang, Baigong
    Kong, Xiangqiang
    Yan, Xunzheng
    Shang, Yanping
    Li, Ying
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 122 : 201 - 209
  • [23] COMPARISON OF THE ENERGY CONSUMPTION OF GROUND-SOURCE AND AIR-TO-WATER PROPANE HEAT PUMPS FOR THE HEATING NEEDS AROUND EUROPE
    Tammaro, M.
    Montagud, C.
    Corberan, J. M.
    Mauro, A. W.
    Mastrullo, R.
    12TH IIR GUSTAV LORENTZEN NATURAL WORKING FLUIDS CONFERENCE, 2016, : 837 - 844
  • [24] Modelling and Experimental Characterisation of a Water-to-Air Thermoelectric Heat Pump with Thermal Energy Storage
    Zhou, Kaixuan
    Zhu, Shunmin
    Wang, Yaodong
    Roskilly, Anthony Paul
    ENERGIES, 2024, 17 (02)
  • [25] Critical cop for an economically feasible industrial heat-pump application
    Feng, X
    Berntsson, T
    APPLIED THERMAL ENGINEERING, 1997, 17 (01) : 93 - 101
  • [26] Annual energy performance of a thermoelectric heat pump combined with a heat recovery unit to HVAC one passive house dwelling
    Diaz de Garayo, S.
    Martinez, A.
    Astrain, D.
    APPLIED THERMAL ENGINEERING, 2022, 204
  • [27] THE ENERGY CONSUMPTION OF REFRIGERATION INSTALLATIONS AND HEAT PUMP POTENTIAL IN 40 DUTCH INDUSTRIAL SECTORS
    Pennartz, A.
    Van Den Bovenkamp, M.
    13TH IIR GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS: NATURAL REFRIGERANT SOLUTIONS FOR WARM CLIMATE COUNTRIES, 2018, : 720 - 724
  • [28] RESEARCH ON DIFFERENT DOMESTIC ENERGY CONSUMPTION PATTERNS BASED ON HEAT PUMP AND THEIR EXERGY ANALYSIS
    Lu, Shuang
    Wu, Jingyi
    ES2008: PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY - 2008, VOL 1, 2009, : 683 - 690
  • [29] Numerical performance of a water source transcritical CO2 heat pump with mechanical subcooling
    Illan-Gomez, Fernando
    Garcia-Cascales, Jose R.
    Velasco, F. J. S.
    Oton-Martinez, Ramon A.
    APPLIED THERMAL ENGINEERING, 2023, 219
  • [30] POTENTIAL ENERGY SAVING AND EMISSIONS REDUCTION USING PROPANE IN AN AIR-TO-WATER HEAT PUMP SYSTEM FOR HEATING AND COOLING IN RESIDENTIAL AND SERVICE BUILDINGS
    Botticella, F.
    De Rossi, F.
    Mauro, A. W.
    Nota, C.
    Vanoli, G. P.
    12TH IIR GUSTAV LORENTZEN NATURAL WORKING FLUIDS CONFERENCE, 2016, : 827 - 836